APPROPRIATE USE

The GAS ALARM GX-B1pro is a gas warning device for city, natural and liquefied gases
and can already deliver a warning at a gas concentration that lies well below life-threatening
values. This monitoring system is, therefore, in line with its purpose, set to a very high sen-
sitivity (see table TECHNICAL DATA). The alarm is signalled acoustically and optically. The
unit is suitable for normal household use and may not be used in areas at risk of explosion.
Another use of the device as described above is not authorized.

TECHNICAL SPECIFICATIONS

Operating voltage:
Power consumption:
Protection type:
Acoustic pressure sounder:
Type Sensor:
Operating temperature:
Storage temperaturer:
Humidity (ambient):
Service life:
Dimensions (HxWxD):
Data diagram Sensor
Gas type
CO
Methane
Propane (isobutane)
Ethanol (acetone)

INSTALLATION INSTRUCTIONS

The GAS ALARM GX-B1pro may only be installed in dry, interior rooms and must be correctly
placed according to the type of gas to ensure faultless operation of the alarm system.
It is essential to observe the prescribed position of the alarm unit! For your
own safety and reassurance, please obtain information from your supplier
regarding their gas type and its properties!
8
230 (+/-10%) V AC / 50-60 Hz
approx. 3 W
IP 20
90 dB @ 10 cm
catalyitc
-10 °C / +50 °C
-20 °C / +70 °C
5–90 % RH (non-condensing)
approx. 5 years
118x60x44 mm
Minimum concentration
no alarm triggered
<5000 ppm (0,5%)
<2000 ppm (0,2%)
<5000 ppm (0,5%)