Auto Tuning Procedure; Self Test Troubleshooting; Phoenix Self Test Troubleshooting - Nokia RM-509 Service Manual

Mobile phones
Hide thumbs Also See for RM-509:
Table of Contents

Advertisement

RM-509; RM-510; RM-511
RF Troubleshooting
• Signal analyser (TX), signal generator (RX) and RF-splitter or one device including all.

Auto tuning procedure

Prerequisites
Install the phone-specific data package, e.g.
The data package defines the phone-specific settings.
Steps
1. Make sure the phone (in the jig) is connected to the equipment. Else, some menus will not be shown in
Phoenix.
2. Go to loss settings by selecting Tuning (Alt_U)→SET LOSS from the menu.
3. Set the loss between CMU200 and the phone. (Total loss = cable + jig)
4. Go to auto tuning by selecting Tuning (Alt_U)→Auto-tune (Alt_A) from the menu.
5. Start auto tuning by clicking the Tune button.

Self test troubleshooting

Phoenix self test troubleshooting

Context
Always start the troubleshooting procedure by running the Phoenix self tests. If a test fails, please follow the
diagram below.
If the phone is dead and you cannot perform the self tests, go to
(page 4–7)
in chapter 3, Baseband troubleshooting and manual tuning guide.
Note:
Self tests are recommended to be made when phone is in jig and a 50Ω load connected to
the RF connector. Otherwise power tests may fail depending on antenna load
Issue 2
Figure 18 Auto tuning concept with CMU200
Nokia_firmware_RM-509_DP20_3.471__sw-ce3.37.exe .
COMPANY CONFIDENTIAL
Copyright © 2009 Nokia. All rights reserved.
Dead or jammed device troubleshooting