Correct Use
The SCR-7 is a universal emergency stop safety switching device
with seven safe relay outputs that can quickly and safely stop the
moving parts of a machine or system in case of danger.
Applications for the SCR-7 include single or dual-channel
emergency stop circuits and guard monitoring on machines and
systems. This safety relay can be delivered with fixed screw
terminals or plug-in terminals.
Features
7 safe, redundant relay outputs
4 auxiliary relay outputs; 2 auxiliary transistor outputs
Connection of:
- Emergency stop buttons
- Safety switches
- Non-contact safety switches
- OSSD-Outputs
Single or dual-channel operation possible
Feedback loop for monitoring downstream contactors or
expansion modules
Cyclical monitoring of the output contacts
Indication of the swiching state via LED
Function
The emergency stop safety switching device SCR-7 is
designed for safe isolation of safety circuits according to EN
60204-1 and can be used up to safety category 4, PL e
according to EN ISO 13849-1.
The internal logical system closes the safety contacts when
the start button is pressed.
If the safety switch is opened, the positively driven safety
contacts are opened and safely switch the machine off. It is
ensured that a single fault does not lead to a loss of the
safety function and that every fault is detected by cyclical
self-monitoring no later than when the system is switched
off and switched on again.
The operating status of the device is indicate by the auxilia-
ry transistor outputs O1 and O2.
O1: Ready. PWR is connected.
O2: Both relay channel K1, K2 are switched on.
Installation
As per EN 60204-1, the device is intended for installation in
control cabinets with a minimum degree of protection of
IP54. It is mounted on a 35-mm DIN rail according to
DIN EN 60715 TH35.
Installation and commissioning of the device must be
Safety
performed only by authorized personnel.
Precautions
Observe the country-specific regulations when installing
the device.
The electrical connection of the device is only allowed to
be made with the device isolated.
The wiring of the device must comply with the instruc-
tions in this user information, otherwise there is a risk
that the safety function will be lost.
Electrical
A safety transformer according to IEC 61558-2-6 or a
Connection
power supply unit with electrical isolation from the mains
must be connected.
External fusing of the safety contacts (10 A gG) must be
provided.
A maximum length of the control lines of 1000 meters
with a line cross section of 0.75 mm
ceeded.
The line cross section must not exceed 2.5 mm
If the device does not function after commissioning, it
must be returned to the manufacturer unopened. Ope-
ning the device will void the warranty.
2 start behavior possible:
- Monitored manual start
- Automatic start
Up to PL e, SILCL 3, category 4
STOP-category: 0
Fig. 1 Block diagramm SCR-7
Fig. 2 Installation / removal
It is not allowed to open the device, tamper with the de-
vice or bypass the safety devices.
All relevant safety regulations and standards are to be
observed.
The overall concept of the control system in which the
device is incorporated must be validated by the user.
Failure to observe the safety regulations can result in
death, serious injury and serious damage.
2
must not be ex-
2
.
SCR-7
A1:
Power Supply
A2 :
Power Supplay
S11:
DC 24V control voltage
S10:
Control line
S12:
Control line
S13:
Control line
S14:
Control line
S21:
Start, Control line
O1;O2:
Aux transistor outputs
0V:
Reference common O1, O2
81-82:
Auxiliary Contact
91-92:
Auxiliary Contact
101-102: Auxiliary Contact
101-112: Auxiliary Contact
13-14 bis 73-74:
Safety Out1-7
Fig. 3 Connections
H04
Ver. A
E61-329-00

Advertisement

loading

Summary of Contents for Idem SCR-7

  • Page 1 SCR-7 User Information Correct Use The SCR-7 is a universal emergency stop safety switching device with seven safe relay outputs that can quickly and safely stop the moving parts of a machine or system in case of danger. Applications for the SCR-7 include single or dual-channel emergency stop circuits and guard monitoring on machines and systems.
  • Page 2 Safety Relays from IDEM SCR-7 User Information Depending on the application or the result of the risk assessment according to EN ISO 13849-1, the de- Applications vice must be wired as shown in Fig. 1 to Fig. 11. Emergency Stop Circuit Fig.
  • Page 3 Additional data can be requested from the manufacturer for According to applications that deviate from these conditions. EN ISO 13849-1 Safety characteristics according to EN ISO 13849-1 for all variants of SCR-7 Load (DC-13; 24V) <= 0,1A <= 1A <= 2A...
  • Page 4 AC/DC 24V (50-60Hz), plug-in terminals Ver. A E61-329-00 IDEM SAFETY SWITCHES Ltd, 2 Ormside Close, Hindley Industrial Estate ,Hindley Green, Wigan, WN2 4HR UK, Tel: +44 (0)1942 261000 Fax.: +44 (0)1942 676293 IDEM ( U.S.A.) - 3909 Washington Blvd. 204, Fremont, CA 94538 email: sales@idemsafety.com...