D A IK IN ROOM AIR CON D ITI ON E R OPERATION MANUAL M ODEL S FTXM20W1VMA FTXM25W1VMA FTXM35W1VMA FTXM46W1VMA [Sticker attachment area] Attach the SSID&KEY sticker of wireless LAN connecting adapter to the sticker attachment area and keep safe.
Page 2
Features Enhanced comfort, energy savings and air cleaning INTELLIGENT EYE The INTELLIGENT EYE sensor detects human movement and adjusts the right and left airflow direction. If no one is in the room for more than 20 minutes, the operation automatically changes to energy saving operation.
Contents Read Before Operation Safety Precautions .......... Names of Parts ..........Preparation Before Operation ...... Basic Operation AUTO · DRY · COOL · HEAT · FAN Operation ........Adjusting the Airflow Rate ....Adjusting the Airflow Direction ... Useful Functions MOLD PROOF Operation ....
Read Before Operation Safety Precautions Read the precautions in this manual carefully This appliance is filled with R32. before operating the unit. • Keep this manual where the user can easily find it. • The precautions described herein are classified as WARNING and CAUTION. They both contain important information regarding safety.
Page 5
Read Before Operation • Do not sit on the outdoor unit, put things on the unit, or pull the unit. Doing so may cause accidents, such as falling or toppling down, thus resulting in injury, product malfunctioning, or product damage. •...
Read Before Operation Names of Parts Air inlet Indoor Unit Room temperature Front panel sensor and Room humidity sensor • Sense air temperature and humidity around the unit. Streamer air inlet • Air inlet for streamer operation. Flaps (horizontal blades) Air outlet INTELLIGENT EYE sensor...
Page 7
Read Before Operation Open the front panel Backside of the front panel Fixing tab Panel support plate Wireless LAN connecting adapter (inside) Page 7,34 Streamer unit (inside) Prevents mold and allergens with the decomposition power of the streamer discharge. SSID&KEY sticker of wireless LAN connecting adapter Air filter...
Page 8
Read Before Operation Names of Parts Wireless LAN connecting adapter The wireless LAN connecting adapter function requires the DAIKIN Mobile Controller application for connecting to the air conditioner and controlling it via your smartphone or tablet over your network. ATTENTION •...
Page 9
Read Before Operation Remote Controller Signal transmitter Display (LCD) • Displays the current settings. Receiver (In this illustration, each section is shown with all its displays on for the • To use the remote controller, aim the purpose of explanation.) transmitter at the indoor unit.
Page 10
Read Before Operation Names of Parts Open the front cover MODE selector button • Selects the operation mode. (AUTO/DRY/COOL/HEAT/FAN) Page 13 ECONO/QUIET button • ECONO/OUTDOOR UNIT QUIET operation. Page 24 SENSOR button • INTELLIGENT EYE operation. SWING button and Page 21 MENU button SWING button...
Read Before Operation Preparation Before Operation CAUTION Incorrect handling of batteries can result in injury from battery leakage, rupturing or heating, or lead to equipment failure. Please observe the following precautions and use safely. • If the alkaline solution from the batteries should get in the eyes, do not rub the eyes. Instead, immediately flush the eyes with tap water and seek the attention of a medical professional.
Page 12
Read Before Operation Preparation Before Operation To set the clock Press “ ” appears on the LCD. “ ” and “ ” blink. Press to set the current day of the week. Display Day of the week Monday Tuesday Wednesday Thursday Friday...
Page 13
Read Before Operation To set the brightness of the indoor unit lamps Adjust the brightness of the indoor unit display as desired, or turn OFF the display. To set Press and hold the button for 2 seconds. • ‘‘ ”...
Basic Operation AUTO · DRY · COOL · HEAT · FAN Operation The air conditioner operates with the operation mode of your choice. From the next time on, the air conditioner will operate with the same operation mode. To start Press and select an operation mode.
Page 15
Basic Operation To change the temperature setting Press • Press to raise the temperature and press to lower the temperature. Each pressing of the button changes the temperature by 0.5°C. COOL HEAT AUTO DRY/FAN operation operation operation operation The temperature setting 18.0~32.0°C 10.0~30.0°C 18.0~30.0°C...
Basic Operation Adjusting the Airflow Rate You can adjust the airflow rate to increase your comfort. To adjust the airflow rate setting Press • Each pressing of the button changes the airflow rate setting in sequence. AUTO Indoor unit quiet Airflow rate 1-5 (Low to High) •...
Basic Operation Adjusting the Airflow Direction You can adjust the airflow direction to increase your comfort. ATTENTION • Always use a remote controller to adjust the angles of the flaps and louvres. − If you attempt to move the flaps and louvres forcibly by hand when they are swinging, the mechanism may be damaged.
Useful Functions MOLD PROOF Operation The inside of the air conditioner is dried to reduce the occurrence of mold and odour. When COOL or DRY operation is performed, condensation may occur inside the air conditioner and may cause mold or odour. It is recommended to dry the inside of the air conditioner using MOLD PROOF operation.
Page 19
Useful Functions NOTE Notes on MOLD PROOF operation • The flaps may sometimes close to increase the drying effect inside the air conditioner. • MOLD PROOF operation may not be performed if the COOL or DRY operation time is short. •...
Useful Functions FLASH STREAMER AIR CLEANING operation The streamer generates a high-speed electron stream with a high oxidizing power, reducing bad odours and viruses. Together with the deodorizing filter (enzyme blue) and the air filters, this function cleans the air in the room. ...
Useful Functions COMFORT AIRFLOW Operation The flow of air will be in the upward direction while in COOL/DRY operation and in the downward direction while in HEAT operation, which will provide a comfortable wind that will not come in direct contact with people. Airflow direction : Upward Airflow direction : Downward (ceiling spread airflow)
Useful Functions INTELLIGENT EYE Operation The INTELLIGENT EYE sensor detects human movement and adjusts airflow direction. It can be set to avoid people or to direct airflow specifically at people. If no one is in the room for more than 20 minutes, the operation automatically changes to energy saving operation.
Page 23
Useful Functions How INTELLIGENT EYE operation works The INTELLIGENT EYE sensor detects human movement and adjusts the right and left airflow direction. If no one is in the room for more than 20 minutes, the operation automatically changes to energy saving operation.
Useful Functions POWERFUL Operation POWERFUL operation quickly maximises the cooling (heating) effect in any operation mode. In this mode, the air conditioner operates at maximum capacity. To start Press during operation. • “ ” appears on the LCD. • POWERFUL operation ends in 20 minutes. Then the system automatically operates again with the previous settings which were used before POWERFUL operation.
Useful Functions ECONO / OUTDOOR UNIT QUIET Operation ECONO operation enables efficient operation by limiting the maximum power consumption. This function is useful to prevent the circuit breaker from tripping when the unit operates alongside other appliances on the same circuit. OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit by changing the frequency and fan speed of the outdoor unit.
TIMER Operation ON/OFF TIMER Operation Timer functions are useful for automatically switching the air conditioner on or off at night or in the morning. You can also use the ON TIMER and OFF TIMER together. [ON TIMER with a 24 hour clock display] (24 HOUR ON/OFF TIMER) ...
Page 27
TIMER Operation [OFF TIMER with a 24 hour clock display] (24 HOUR ON/OFF TIMER) To set • Check that the clock is correct. If not, set the clock to the present time. Page 11 Press “ ” appears on the LCD. “ ...
Page 28
TIMER Operation ON/OFF TIMER Operation [ON/OFF TIMER with an hours remaining display] (COUNT UP-DOWN ON/OFF TIMER) • Check that the clock is correct. If not, set the clock to the present time. Page 11 Press and hold for about 5 seconds, when signal indicater ( ) blink, release your finger from the button.
TIMER Operation WEEKLY TIMER Operation Up to 4 timer settings can be saved for each day of the week. This is convenient to adapt the WEEKLY TIMER to your family’s life style. Setting example of the WEEKLY TIMER The same timer settings are used from Monday through Friday, while different timer settings are used for the weekend. [Monday] Make timer settings for programmes 1-4.
Page 30
TIMER Operation WEEKLY TIMER Operation To use WEEKLY TIMER operation Setting mode • Make sure the day of the week and time are set. If not, set the day of the week and time. Page 11 Programme 1 Programme 2 Programme 3 Programme 4 [Monday] 25.0°C...
Page 31
TIMER Operation Press to select the desired time. • The time can be set between 0:00 and 23:50 in 10-minute intervals. • To return to the ON/OFF TIMER mode setting, press • Proceed to STEP when setting the OFF TIMER. Press •...
Page 32
TIMER Operation WEEKLY TIMER Operation Copy mode • A reservation made once can be copied to another day of the week. The whole reservation of the selected day of the week will be copied. Programme 1 Programme 2 Programme 3 Programme 4 [Monday] 25.0°C...
Page 33
TIMER Operation Confirming a reservation • The reservation can be confirmed. Setting Displays Normal Confirmation Press • The day of the week and the reservation number of the current day will be displayed. Press to select the day of the week and the reservation number to be confirmed.
Page 34
TIMER Operation WEEKLY TIMER Operation To delete a reservation An individual reservation Press • The day of the week and the reservation number will be displayed. Press to select the day of the week and the reservation number to be deleted. Press •...
• Before downloading the application software for installation, please read ‘‘Configuration” on Page 7 For Android phones 1) Open [Google Play]. 2) Search using the application name: [DAIKIN Mobile Controller]. 3) Follow the on-screen instructions for installation. For iOS phones 1) Open [App Store].
Page 36
System control via Smart Control Wireless LAN connection Enabling/disabling the wireless LAN connecting adapter To enable While operation is stopped, press and hold the button for 5 seconds. • “ ” appears on the LCD. • “ ” (SP menu) blinks. Press and select SP menu .
Page 37
NOTE. Press to return to the default screen. Connect your smart phone to your home network. Open the Home screen of the DAIKIN Mobile Fig. 1 Controller application. The air conditioner will be listed there (Fig. 1). NOTE Note on simple connection (WPS connection) •...
Page 38
• The wireless LAN connecting adapter lamp (orange) stays lit. If you fail to connect, refer to NOTE. Connect your smart phone to your home network. Open the Home screen of the DAIKIN Mobile Controller application. The air conditioner will be listed there.
Care Care and Cleaning CAUTION • Before cleaning, be sure to stop the operation and turn off the circuit breaker. • Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury. ...
Page 40
Care Care and Cleaning Air filter Open the front panel. Wash the air filters with water or clean them with • Hold the front panel by the sides and open it. vacuum cleaner. Backside of the front panel • It is recommended to clean the air filters every 2 weeks.
Page 41
Care Filter (small) * For the applicable filter type, please refer to Page 38 Attaching Clean or replace. [Cleaning] Open the front panel and pull out the air filters. Deodorizing filter (enzyme blue) : Blue Page 39 / Titanium apatite deodorizing filter : Insert the filter.
Page 42
Care Care and Cleaning Prior to a long period of non-use Operate the MOLD PROOF mode. Page 17 After operation stops, turn off the circuit breaker for the room air conditioner. Clean the air filters and reattach them. Page 39 To prevent battery leakage, take out the batteries from the remote controller.
Page 43
When the Need Arises Indoor unit The flaps do not start swinging immediately. • The air conditioner is adjusting the position of the flaps. The flaps will start moving soon. The air conditioner stops generating Commonly occurring sounds. airflow during HEAT operation. ...
Page 44
When the Need Arises Troubleshooting Before making an inquiry or a request for repair, please check the following. If the problem persists, consult your dealer. Not a problem Check This case is not a problem. Please check again before requesting repairs. Air conditioner The air conditioner does not operate Case...
Page 45
When the Need Arises Air conditioner Mist comes out Case Description / what to check • This happens when the air in the room is cooled into mist by the cold airflow during COOL Mist comes out of the indoor unit. or other operation.
Page 46
• Refer to the FAQ on: None of the above work. http://www.daikinthai.com/product/dmobile For instructions about how to operate the DAIKIN Mobile Controller application, please refer to the operation manual at http://www.daikinthai.com/product/dmobile Call your dealer immediately WARNING When an abnormality (such as a burning smell) occurs, stop operation and turn off the circuit breaker.
Page 47
When the Need Arises Fault diagnosis by remote controller • In case the air conditioner is malfunctioning, you can check the error code via the remote controller before consulting with service personnel and informing them of the malfunction code. When is held down for about 5 seconds, “...
Page 48
Quick Reference On/Off Temp Mode Swing MODE The two-dimensional bar code is a manufacturing code. 3P683779-3 M22N003 (2203) HT...
Page 49
D A IK IN ROOM AIR CON D ITI ON E R OPERATION MANUAL M ODEL S FTXM50W1VMA FTXM60W1VMA FTXM71W1VMA [Sticker attachment area] Attach the SSID&KEY sticker of wireless LAN connecting adapter to the sticker attachment area and keep safe.
Page 50
Features Enhanced comfort, energy savings and air cleaning INTELLIGENT EYE The INTELLIGENT EYE sensor detects human movement in a room. If no one is in the room for more than 20 minutes, the operation automatically changes to energy saving operation. Page 21 WEEKLY TIMER Up to 4 timer settings can be saved for each day of the week...
Contents Read Before Operation Safety Precautions .......... Names of Parts ..........Preparation Before Operation ...... Basic Operation AUTO · DRY · COOL · HEAT · FAN Operation ........Adjusting the Airflow Rate ....Adjusting the Airflow Direction ... Useful Functions MOLD PROOF Operation ....
Read Before Operation Safety Precautions Read the precautions in this manual carefully This appliance is filled with R32. before operating the unit. • Keep this manual where the user can easily find it. • The precautions described herein are classified as WARNING and CAUTION. They both contain important information regarding safety.
Page 53
Read Before Operation • Do not sit on the outdoor unit, put things on the unit, or pull the unit. Doing so may cause accidents, such as falling or toppling down, thus resulting in injury, product malfunctioning, or product damage. •...
Read Before Operation Names of Parts Indoor Unit Air inlet Room temperature Front panel sensor and Room humidity sensor • Sense air temperature and humidity around the unit. Streamer air inlet • Air inlet for streamer operation. Air outlet Flaps INTELLIGENT EYE (horizontal blades)
Page 55
Read Before Operation Open the front panel Backside of the front panel Fixing tab Panel support plate Wireless LAN connecting adapter (inside) Page 7, 34 Streamer unit (inside) Prevents mold and allergens with the decomposition power of the streamer discharge. SSID&KEY sticker of wireless LAN connecting adapter Air filter...
Page 56
Read Before Operation Names of Parts Wireless LAN connecting adapter The wireless LAN connecting adapter function requires the DAIKIN Mobile Controller application for connecting to the air conditioner and controlling it via your smartphone or tablet over your network. ATTENTION •...
Page 57
Read Before Operation Remote Controller Signal transmitter Display (LCD) Receiver • Displays the current settings. (In this illustration, each section is shown with all its displays on for the • To use the remote controller, aim the purpose of explanation.) transmitter at the indoor unit.
Page 58
Read Before Operation Names of Parts Open the front cover MODE selector button • Selects the operation mode. (AUTO/DRY/COOL/HEAT/FAN) Page 13 ECONO/QUIET button • ECONO/OUTDOOR UNIT QUIET operation. Page 24 SENSOR button • INTELLIGENT EYE operation. SWING button and Page 21 MENU button SWING button...
Read Before Operation Preparation Before Operation CAUTION Incorrect handling of batteries can result in injury from battery leakage, rupturing or heating, or lead to equipment failure. Please observe the following precautions and use safely. • If the alkaline solution from the batteries should get in the eyes, do not rub the eyes. Instead, immediately flush the eyes with tap water and seek the attention of a medical professional.
Page 60
Read Before Operation Preparation Before Operation To set the clock Press “ ” appears on the LCD. “ ” and “ ” blink. Press to set the current day of the week. Display Day of the week Monday Tuesday Wednesday Thursday Friday...
Page 61
Read Before Operation To set the brightness of the indoor unit lamps Adjust the brightness of the indoor unit display as desired, or turn OFF the display. To set Press and hold the button for 2 seconds. • ‘‘ ”...
Basic Operation AUTO · DRY · COOL · HEAT · FAN Operation The air conditioner operates with the operation mode of your choice. From the next time on, the air conditioner will operate with the same operation mode. To start Press and select an operation mode.
Page 63
Basic Operation To change the temperature setting Press • Press to raise the temperature and press to lower the temperature. Each pressing of the button changes the temperature by 0.5°C. COOL HEAT AUTO DRY/FAN operation operation operation operation The temperature setting 18.0~32.0°C 10.0~30.0°C 18.0~30.0°C...
Basic Operation Adjusting the Airflow Rate You can adjust the airflow rate to increase your comfort. To adjust the airflow rate setting Press • Each pressing of the button changes the airflow rate setting in sequence. AUTO Indoor unit quiet Airflow rate 1-5 (Low to High) •...
Basic Operation Adjusting the Airflow Direction You can adjust the airflow direction to increase your comfort. ATTENTION • Always use a remote controller to adjust the angles of the flaps and louvres. − If you attempt to move the flaps and louvres forcibly by hand when they are swinging, the mechanism may be damaged.
Useful Functions MOLD PROOF Operation The inside of the air conditioner is dried to reduce the occurrence of mold and odour. When COOL or DRY operation is performed, condensation may occur inside the air conditioner and may cause mold or odour. It is recommended to dry the inside of the air conditioner using MOLD PROOF operation.
Page 67
Useful Functions NOTE Notes on MOLD PROOF operation • The flaps may sometimes close to increase the drying effect inside the air conditioner. • MOLD PROOF operation may not be performed if the COOL or DRY operation time is short. •...
Useful Functions FLASH STREAMER AIR CLEANING operation The streamer generates a high-speed electron stream with a high oxidizing power, reducing bad odours and viruses. Together with the deodorizing filter (enzyme blue) and the air filters, this function cleans the air in the room. ...
Useful Functions COMFORT AIRFLOW Operation The flow of air will be in the upward direction while in COOL/DRY operation and in the downward direction while in HEAT operation, which will provide a comfortable wind that will not come in direct contact with people. Airflow direction : Upward Airflow direction : Downward (ceiling spread airflow)
Useful Functions INTELLIGENT EYE Operation The INTELLIGENT EYE operation detects human movement. If no one is detected in the room for more than 20 minutes, the unit automatically enters energy saving operation. CAUTION • Do not place large objects near the INTELLIGENT EYE sensor. Also keep heating units and humidifiers outside the sensor’s detection area.
Page 71
Useful Functions INTELLIGENT EYE operation is useful for energy saving People are detected in the sensing area. No people are detected in the sensing area. The air conditioner is in normal operation while The air conditioner will switch to energy-saving mode after the sensor is detecting human movement.
Useful Functions POWERFUL Operation POWERFUL operation quickly maximises the cooling (heating) effect in any operation mode. In this mode, the air conditioner operates at maximum capacity. To start Press during operation. • “ ” appears on the LCD. • POWERFUL operation ends in 20 minutes. Then the system automatically operates again with the previous settings which were used before POWERFUL operation.
Useful Functions ECONO / OUTDOOR UNIT QUIET Operation ECONO operation enables efficient operation by limiting the maximum power consumption. This function is useful to prevent the circuit breaker from tripping when the unit operates alongside other appliances on the same circuit. OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit by changing the frequency and fan speed of the outdoor unit.
TIMER Operation ON/OFF TIMER Operation Timer functions are useful for automatically switching the air conditioner on or off at night or in the morning. You can also use the ON TIMER and OFF TIMER together. [ON TIMER with a 24 hour clock display] (24 HOUR ON/OFF TIMER) ...
Page 75
TIMER Operation [OFF TIMER with a 24 hour clock display] (24 HOUR ON/OFF TIMER) To set • Check that the clock is correct. If not, set the clock to the present time. Page 11 Press “ ” appears on the LCD. “ ...
Page 76
TIMER Operation ON/OFF TIMER Operation [ON/OFF TIMER with an hours remaining display] (COUNT UP-DOWN ON/OFF TIMER) • Check that the clock is correct. If not, set the clock to the present time. Page 11 Press and hold for about 5 seconds, when signal indicater ( ) blink, release your finger from the button.
TIMER Operation WEEKLY TIMER Operation Up to 4 timer settings can be saved for each day of the week. This is convenient to adapt the WEEKLY TIMER to your family’s life style. Setting example of the WEEKLY TIMER The same timer settings are used from Monday through Friday, while different timer settings are used for the weekend. [Monday] Make timer settings for programmes 1-4.
Page 78
TIMER Operation WEEKLY TIMER Operation To use WEEKLY TIMER operation Setting mode • Make sure the day of the week and time are set. If not, set the day of the week and time. Page 11 Programme 1 Programme 2 Programme 3 Programme 4 [Monday] 25.0°C...
Page 79
TIMER Operation Press to select the desired time. • The time can be set between 0:00 and 23:50 in 10-minute intervals. • To return to the ON/OFF TIMER mode setting, press • Proceed to STEP when setting the OFF TIMER. Press •...
Page 80
TIMER Operation WEEKLY TIMER Operation Copy mode • A reservation made once can be copied to another day of the week. The whole reservation of the selected day of the week will be copied. Programme 1 Programme 2 Programme 3 Programme 4 [Monday] 25.0°C...
Page 81
TIMER Operation Confirming a reservation • The reservation can be confirmed. Setting Displays Normal Confirmation Press • The day of the week and the reservation number of the current day will be displayed. Press to select the day of the week and the reservation number to be confirmed.
Page 82
TIMER Operation WEEKLY TIMER Operation To delete a reservation An individual reservation Press • The day of the week and the reservation number will be displayed. Press to select the day of the week and the reservation number to be deleted. Press •...
• Before downloading the application software for installation, please read ‘‘Configuration” on Page 7 For Android phones 1) Open [Google Play]. 2) Search using the application name: [DAIKIN Mobile Controller]. 3) Follow the on-screen instructions for installation. For iOS phones 1) Open [App Store]. 2) Search using the application name: [DAIKIN Mobile Controller].
Page 84
System control via Smart Control Wireless LAN connection Enabling/disabling the wireless LAN connecting adapter To enable While operation is stopped, press and hold the button for 5 seconds. • “ ” appears on the LCD. • “ ” (SP menu) blinks. Press and select SP menu .
Page 85
NOTE. Press to return to the default screen. Connect your smart phone to your home network. Open the Home screen of the DAIKIN Mobile Fig. 1 Controller application. The air conditioner will be listed there (Fig. 1). NOTE Note on simple connection (WPS connection) •...
Page 86
• The wireless LAN connecting adapter lamp (orange) stays lit. If you fail to connect, refer to NOTE. Connect your smart phone to your home network. Open the Home screen of the DAIKIN Mobile Controller application. The air conditioner will be listed there.
Care Care and Cleaning CAUTION • Before cleaning, be sure to stop the operation and turn off the circuit breaker. • Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury. ...
Page 88
Care Care and Cleaning Air filter Open the front panel. Wash the air filters with water or clean them with • Hold the front panel by the sides and open it. vacuum cleaner. Backside of the front panel • It is recommended to clean the air filters every 2 weeks.
Page 89
Care Filter (small) * For the applicable filter type, please refer to Page 38 Attaching Clean or replace. [Cleaning] Open the front panel and pull out the air filters. Deodorizing filter (enzyme blue) : Blue Page 39 / Titanium apatite deodorizing filter : Insert the filter.
Page 90
Care Care and Cleaning Prior to a long period of non-use Operate the MOLD PROOF mode. Page 17 After operation stops, turn off the circuit breaker for the room air conditioner. Clean the air filters and reattach them. Page 39 To prevent battery leakage, take out the batteries from the remote controller.
Page 91
When the Need Arises Indoor unit The flaps do not start swinging immediately. • The air conditioner is adjusting the position of the flaps. The flaps will start moving soon. The air conditioner stops generating Commonly occurring sounds. airflow during HEAT operation. ...
When the Need Arises Troubleshooting Before making an inquiry or a request for repair, please check the following. If the problem persists, consult your dealer. Not a problem Check This case is not a problem. Please check again before requesting repairs. Air conditioner The air conditioner does not operate Case...
Page 93
When the Need Arises Air conditioner Mist comes out Case Description / what to check • This happens when the air in the room is cooled into mist by the cold airflow during COOL Mist comes out of the indoor unit. or other operation.
Page 94
• Refer to the FAQ on: None of the above work. http://www.daikinthai.com/product/dmobile For instructions about how to operate the DAIKIN Mobile Controller application, please refer to the operation manual at http://www.daikinthai.com/product/dmobile Call your dealer immediately WARNING When an abnormality (such as a burning smell) occurs, stop operation and turn off the circuit breaker.
Page 95
When the Need Arises Fault diagnosis by remote controller • In case the air conditioner is malfunctioning, you can check the error code via the remote controller before consulting with service personnel and informing them of the malfunction code. When is held down for about 5 seconds, “...
Page 96
Quick Reference On/Off Temp Mode Swing MODE The two-dimensional bar code is a manufacturing code. 3P683779-4 M22N004 (2203) HT...
Page 97
D A IK IN ROOM AIR CON D ITI ON E R OPERATION MANUAL M ODEL S FTXM20WVMA FTXM25WVMA FTXM35WVMA FTXM46WVMA FTKM20WVMA FTKM25WVMA FTKM35WVMA FTKM46WVMA [Sticker attachment area] Attach the SSID&KEY sticker of wireless LAN connecting adapter to the sticker attachment area and keep safe.
Page 98
Features Enhanced comfort, energy savings and air cleaning INTELLIGENT EYE The INTELLIGENT EYE sensor detects human movement and adjusts the right and left airflow direction. If no one is in the room for more than 20 minutes, the operation automatically changes to energy saving operation.
Page 99
Contents Read Before Operation Safety Precautions .......... Names of Parts ..........Preparation Before Operation ...... Basic Operation AUTO · DRY · COOL · HEAT · FAN Operation ........Adjusting the Airflow Rate ....Adjusting the Airflow Direction ... Useful Functions MOLD PROOF Operation ....
Read Before Operation Safety Precautions Read the precautions in this manual carefully This appliance is filled with R32. before operating the unit. • Keep this manual where the user can easily find it. • The precautions described herein are classified as WARNING and CAUTION. They both contain important information regarding safety.
Page 101
Read Before Operation • Do not sit on the outdoor unit, put things on the unit, or pull the unit. Doing so may cause accidents, such as falling or toppling down, thus resulting in injury, product malfunctioning, or product damage. •...
Read Before Operation Names of Parts Air inlet Indoor Unit Room temperature Front panel sensor and Room humidity sensor • Sense air temperature and humidity around the unit. Streamer air inlet • Air inlet for streamer operation. Flaps (horizontal blades) Air outlet INTELLIGENT EYE sensor...
Page 103
Read Before Operation Open the front panel Backside of the front panel Fixing tab Panel support plate Wireless LAN connecting adapter (inside) Page 7,34 Streamer unit (inside) Prevents mold and allergens with the decomposition power of the streamer discharge. SSID&KEY sticker of wireless LAN connecting adapter Air filter...
Page 104
Read Before Operation Names of Parts Wireless LAN connecting adapter The wireless LAN connecting adapter function requires the DAIKIN Mobile Controller application for connecting to the air conditioner and controlling it via your smartphone or tablet over your network. ATTENTION •...
Page 105
Read Before Operation Remote Controller Signal transmitter Display (LCD) • Displays the current settings. (In this illustration, each section is shown with all its displays on for the purpose of explanation.) (Explained by ARC466A76) • For ARC466A77, the display is as follows: Receiver •...
Page 106
Read Before Operation Names of Parts Open the front cover MODE selector button • Selects the operation mode. (AUTO/DRY/COOL/HEAT/FAN) Page 13 ECONO/QUIET button • ECONO/OUTDOOR UNIT QUIET operation. Page 24 SENSOR button • INTELLIGENT EYE operation. SWING button and Page 21 MENU button SWING button...
Read Before Operation Preparation Before Operation CAUTION Incorrect handling of batteries can result in injury from battery leakage, rupturing or heating, or lead to equipment failure. Please observe the following precautions and use safely. • If the alkaline solution from the batteries should get in the eyes, do not rub the eyes. Instead, immediately flush the eyes with tap water and seek the attention of a medical professional.
Page 108
Read Before Operation Preparation Before Operation To set the clock Press “ ” appears on the LCD. “ ” and “ ” blink. Press to set the current day of the week. Display Day of the week Monday Tuesday Wednesday Thursday Friday...
Page 109
Read Before Operation To set the brightness of the indoor unit lamps Adjust the brightness of the indoor unit display as desired, or turn OFF the display. To set Press and hold the button for 2 seconds. • ‘‘ ”...
Basic Operation AUTO · DRY · COOL · HEAT · FAN Operation The air conditioner operates with the operation mode of your choice. From the next time on, the air conditioner will operate with the same operation mode. To start Press and select an operation mode.
Page 111
Basic Operation To change the temperature setting Press • Press to raise the temperature and press to lower the temperature. Each pressing of the button changes the temperature by 0.5°C. COOL HEAT AUTO DRY/FAN operation operation operation operation The temperature setting 18.0~32.0°C 10.0~30.0°C 18.0~30.0°C...
Basic Operation Adjusting the Airflow Rate You can adjust the airflow rate to increase your comfort. To adjust the airflow rate setting Press • Each pressing of the button changes the airflow rate setting in sequence. AUTO Indoor unit quiet Airflow rate 1-5 (Low to High) •...
Basic Operation Adjusting the Airflow Direction You can adjust the airflow direction to increase your comfort. CAUTION • Always use a remote controller to adjust the angles of the flaps and louvres. − If you attempt to move the flaps and louvres forc bly by hand when they are swinging, the mechanism may be damaged.
Useful Functions MOLD PROOF Operation The inside of the air conditioner is dried to reduce the occurrence of mold and odour. When COOL or DRY operation is performed, condensation may occur inside the air conditioner and may cause mold or odour. It is recommended to dry the inside of the air conditioner using MOLD PROOF operation.
Page 115
Useful Functions NOTE Notes on MOLD PROOF operation • The flaps may sometimes close to increase the drying effect inside the air conditioner. • MOLD PROOF operation may not be performed if the COOL or DRY operation time is short. •...
Useful Functions FLASH STREAMER AIR CLEANING operation The streamer generates a high-speed electron stream with a high oxidizing power, reducing bad odours and viruses. Together with the deodorizing filter (enzyme blue) and the air filters, this function cleans the air in the room. ...
Useful Functions COMFORT AIRFLOW Operation The flow of air will be in the upward direction while in COOL/DRY operation and in the downward direction while in HEAT operation, which will provide a comfortable wind that will not come in direct contact with people. Airflow direction : Upward Airflow direction : Downward (ceiling spread airflow)
Useful Functions INTELLIGENT EYE Operation The INTELLIGENT EYE sensor detects human movement and adjusts airflow direction. It can be set to avoid people or to direct airflow specifically at people. If no one is in the room for more than 20 minutes, the operation automatically changes to energy saving operation.
Page 119
Useful Functions How INTELLIGENT EYE operation works The INTELLIGENT EYE sensor detects human movement and adjusts the right and left airflow direction. If no one is in the room for more than 20 minutes, the operation automatically changes to energy saving operation.
Useful Functions POWERFUL Operation POWERFUL operation quickly maximises the cooling (heating) effect in any operation mode. In this mode, the air conditioner operates at maximum capacity. To start Press during operation. • “ ” appears on the LCD. • POWERFUL operation ends in 20 minutes. Then the system automatically operates again with the previous settings which were used before POWERFUL operation.
Useful Functions ECONO / OUTDOOR UNIT QUIET Operation ECONO operation enables efficient operation by limiting the maximum power consumption. This function is useful to prevent the circuit breaker from tripping when the unit operates alongside other appliances on the same circuit. OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit by changing the frequency and fan speed of the outdoor unit.
TIMER Operation ON/OFF TIMER Operation Timer functions are useful for automatically switching the air conditioner on or off at night or in the morning. You can also use the ON TIMER and OFF TIMER together. [ON TIMER with a 24 hour clock display] (24 HOUR ON/OFF TIMER) ...
Page 123
TIMER Operation [OFF TIMER with a 24 hour clock display] (24 HOUR ON/OFF TIMER) To set • Check that the clock is correct. If not, set the clock to the present time. Page 11 Press “ ” appears on the LCD. “ ...
Page 124
TIMER Operation ON/OFF TIMER Operation [ON/OFF TIMER with an hours remaining display] (COUNT UP-DOWN ON/OFF TIMER) • Check that the clock is correct. If not, set the clock to the present time. Page 11 Press and hold for about 5 seconds, when signal indicater ( ) blink, release your finger from the button.
TIMER Operation WEEKLY TIMER Operation Up to 4 timer settings can be saved for each day of the week. This is convenient to adapt the WEEKLY TIMER to your family’s life style. Setting example of the WEEKLY TIMER The same timer settings are used from Monday through Friday, while different timer settings are used for the weekend. [Monday] Make timer settings for programmes 1-4.
Page 126
TIMER Operation WEEKLY TIMER Operation To use WEEKLY TIMER operation Setting mode • Make sure the day of the week and time are set. If not, set the day of the week and time. Page 11 Programme 1 Programme 2 Programme 3 Programme 4 [Monday] 25.0°C...
Page 127
TIMER Operation Press to select the desired time. • The time can be set between 0:00 and 23:50 in 10-minute intervals. • To return to the ON/OFF TIMER mode setting, press • Proceed to STEP when setting the OFF TIMER. Press •...
Page 128
TIMER Operation WEEKLY TIMER Operation Copy mode • A reservation made once can be copied to another day of the week. The whole reservation of the selected day of the week will be copied. Programme 1 Programme 2 Programme 3 Programme 4 [Monday] 25.0°C...
Page 129
TIMER Operation Confirming a reservation • The reservation can be confirmed. Setting Displays Normal Confirmation Press • The day of the week and the reservation number of the current day will be displayed. Press to select the day of the week and the reservation number to be confirmed.
Page 130
TIMER Operation WEEKLY TIMER Operation To delete a reservation An individual reservation Press • The day of the week and the reservation number will be displayed. Press to select the day of the week and the reservation number to be deleted. Press •...
• Before downloading the application software for installation, please read ‘‘Configuration” on Page 7 For Android phones 1) Open [Google Play]. 2) Search using the application name: [DAIKIN Mobile Controller]. 3) Follow the on-screen instructions for installation. For iOS phones 1) Open [App Store].
Page 132
System control via Smart Control Wireless LAN connection Enabling/disabling the wireless LAN connecting adapter To enable While operation is stopped, press and hold the button for 5 seconds. • “ ” appears on the LCD. • “ ” (SP menu) blinks. Press and select SP menu .
Page 133
NOTE. Press to return to the default screen. Connect your smart phone to your home network. Open the Home screen of the DAIKIN Mobile Fig. 1 Controller application. The air conditioner will be listed there (Fig. 1). NOTE Note on simple connection (WPS connection) •...
Page 134
• The wireless LAN connecting adapter lamp (orange) stays lit. If you fail to connect, refer to NOTE. Connect your smart phone to your home network. Open the Home screen of the DAIKIN Mobile Controller application. The air conditioner will be listed there.
Care Care and Cleaning CAUTION • Before cleaning, be sure to stop the operation and turn off the circuit breaker. • Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury. ...
Page 136
Care Care and Cleaning Air filter Open the front panel. Wash the air filters with water or clean them with • Hold the front panel by the sides and open it. vacuum cleaner. Backside of the front panel • It is recommended to clean the air filters every 2 weeks.
Page 137
Care Filter (small) * For the applicable filter type, please refer to Page 38 Attaching Clean or replace. [Cleaning] Open the front panel and pull out the air filters. Deodorizing filter (enzyme blue) : Blue Page 39 / Titanium apatite deodorizing filter : Insert the filter.
Page 138
Care Care and Cleaning Prior to a long period of non-use Operate the MOLD PROOF mode. Page 17 After operation stops, turn off the circuit breaker for the room air conditioner. Clean the air filters and reattach them. Page 39 To prevent battery leakage, take out the batteries from the remote controller.
When the Need Arises Indoor unit The flaps do not start swinging immediately. • The air conditioner is adjusting the position of the flaps. The flaps will start moving soon. The air conditioner stops generating Commonly occurring sounds. airflow during HEAT operation. ...
When the Need Arises Troubleshooting Before making an inquiry or a request for repair, please check the following. If the problem persists, consult your dealer. Not a problem Check This case is not a problem. Please check again before requesting repairs. Air conditioner The air conditioner does not operate Case...
Page 141
When the Need Arises Air conditioner Mist comes out Case Description / what to check • This happens when the air in the room is cooled into mist by the cold airflow during COOL Mist comes out of the indoor unit. or other operation.
Page 142
• Refer to the FAQ on: None of the above work. http://www.daikinthai.com/product/dmobile For instructions about how to operate the DAIKIN Mobile Controller application, please refer to the operation manual at http://www.daikinthai.com/product/dmobile Call your dealer immediately WARNING When an abnormality (such as a burning smell) occurs, stop operation and turn off the circuit breaker.
Page 143
When the Need Arises Fault diagnosis by remote controller • In case the air conditioner is malfunctioning, you can check the error code via the remote controller before consulting with service personnel and informing them of the malfunction code. When is held down for about 5 seconds, “...
Page 144
Quick Reference On/Off Temp Mode Swing MODE The two-dimensional bar code is a manufacturing code. 3P651499-1 M21N017 (2106) HT...
Page 145
D A IK IN ROOM AIR CON D ITI ON E R OPERATION MANUAL M ODEL S FTXM50WVMA FTXM60WVMA FTXM71WVMA FTKM50WVMA FTKM60WVMA FTKM71WVMA [Sticker attachment area] Attach the SSID&KEY sticker of wireless LAN connecting adapter to the sticker attachment area and keep safe.
Page 146
Features Enhanced comfort, energy savings and air cleaning INTELLIGENT EYE The INTELLIGENT EYE sensor detects human movement in a room. If no one is in the room for more than 20 minutes, the operation automatically changes to energy saving operation. Page 21 WEEKLY TIMER Up to 4 timer settings can be saved for each day of the week...
Page 147
Contents Read Before Operation Safety Precautions .......... Names of Parts ..........Preparation Before Operation ...... Basic Operation AUTO · DRY · COOL · HEAT · FAN Operation ........Adjusting the Airflow Rate ....Adjusting the Airflow Direction ... Useful Functions MOLD PROOF Operation ....
Read Before Operation Safety Precautions Read the precautions in this manual carefully This appliance is filled with R32. before operating the unit. • Keep this manual where the user can easily find it. • The precautions described herein are classified as WARNING and CAUTION. They both contain important information regarding safety.
Page 149
Read Before Operation • Do not sit on the outdoor unit, put things on the unit, or pull the unit. Doing so may cause accidents, such as falling or toppling down, thus resulting in injury, product malfunctioning, or product damage. •...
Read Before Operation Names of Parts Indoor Unit Air inlet Room temperature Front panel sensor and Room humidity sensor • Sense air temperature and humidity around the unit. Streamer air inlet • Air inlet for streamer operation. Air outlet Flaps INTELLIGENT EYE (horizontal blades)
Page 151
Read Before Operation Open the front panel Backside of the front panel Fixing tab Panel support plate Wireless LAN connecting adapter (inside) Page 7, 34 Streamer unit (inside) Prevents mold and allergens with the decomposition power of the streamer discharge. SSID&KEY sticker of wireless LAN connecting adapter Air filter...
Page 152
Read Before Operation Names of Parts Wireless LAN connecting adapter The wireless LAN connecting adapter function requires the DAIKIN Mobile Controller application for connecting to the air conditioner and controlling it via your smartphone or tablet over your network. ATTENTION •...
Page 153
Read Before Operation Remote Controller Signal transmitter Display (LCD) Receiver • Displays the current settings. (In this illustration, each section is shown with all its displays on for the • To use the remote controller, aim the purpose of explanation.) transmitter at the indoor unit.
Page 154
Read Before Operation Names of Parts Open the front cover MODE selector button • Selects the operation mode. (AUTO/DRY/COOL/HEAT/FAN) Page 13 ECONO/QUIET button • ECONO/OUTDOOR UNIT QUIET operation. Page 24 SENSOR button • INTELLIGENT EYE operation. SWING button and Page 21 MENU button SWING button...
Read Before Operation Preparation Before Operation CAUTION Incorrect handling of batteries can result in injury from battery leakage, rupturing or heating, or lead to equipment failure. Please observe the following precautions and use safely. • If the alkaline solution from the batteries should get in the eyes, do not rub the eyes. Instead, immediately flush the eyes with tap water and seek the attention of a medical professional.
Page 156
Read Before Operation Preparation Before Operation To set the clock Press “ ” appears on the LCD. “ ” and “ ” blink. Press to set the current day of the week. Display Day of the week Monday Tuesday Wednesday Thursday Friday...
Page 157
Read Before Operation To set the brightness of the indoor unit lamps Adjust the brightness of the indoor unit display as desired, or turn OFF the display. To set Press and hold the button for 2 seconds. • ‘‘ ”...
Basic Operation AUTO · DRY · COOL · HEAT · FAN Operation The air conditioner operates with the operation mode of your choice. From the next time on, the air conditioner will operate with the same operation mode. To start Press and select an operation mode.
Page 159
Basic Operation To change the temperature setting Press • Press to raise the temperature and press to lower the temperature. Each pressing of the button changes the temperature by 0.5°C. COOL HEAT AUTO DRY/FAN operation operation operation operation The temperature setting 18.0~32.0°C 10.0~30.0°C 18.0~30.0°C...
Basic Operation Adjusting the Airflow Rate You can adjust the airflow rate to increase your comfort. To adjust the airflow rate setting Press • Each pressing of the button changes the airflow rate setting in sequence. AUTO Indoor unit quiet Airflow rate 1-5 (Low to High) •...
Basic Operation Adjusting the Airflow Direction You can adjust the airflow direction to increase your comfort. CAUTION • Always use a remote controller to adjust the angles of the flaps and louvres. − If you attempt to move the flaps and louvres forc bly by hand when they are swinging, the mechanism may be damaged.
Useful Functions MOLD PROOF Operation The inside of the air conditioner is dried to reduce the occurrence of mold and odour. When COOL or DRY operation is performed, condensation may occur inside the air conditioner and may cause mold or odour. It is recommended to dry the inside of the air conditioner using MOLD PROOF operation.
Page 163
Useful Functions NOTE Notes on MOLD PROOF operation • The flaps may sometimes close to increase the drying effect inside the air conditioner. • MOLD PROOF operation may not be performed if the COOL or DRY operation time is short. •...
Useful Functions FLASH STREAMER AIR CLEANING operation The streamer generates a high-speed electron stream with a high oxidizing power, reducing bad odours and viruses. Together with the deodorizing filter (enzyme blue) and the air filters, this function cleans the air in the room. ...
Useful Functions COMFORT AIRFLOW Operation The flow of air will be in the upward direction while in COOL/DRY operation and in the downward direction while in HEAT operation, which will provide a comfortable wind that will not come in direct contact with people. Airflow direction : Upward Airflow direction : Downward (ceiling spread airflow)
Useful Functions INTELLIGENT EYE Operation The INTELLIGENT EYE operation detects human movement. If no one is detected in the room for more than 20 minutes, the unit automatically enters energy saving operation. CAUTION • Do not place large objects near the INTELLIGENT EYE sensor. Also keep heating units and humidifiers outside the sensor’s detection area.
Page 167
Useful Functions INTELLIGENT EYE operation is useful for energy saving People are detected in the sensing area. No people are detected in the sensing area. The air conditioner is in normal operation while The air conditioner will switch to energy-saving mode after the sensor is detecting human movement.
Useful Functions POWERFUL Operation POWERFUL operation quickly maximises the cooling (heating) effect in any operation mode. In this mode, the air conditioner operates at maximum capacity. To start Press during operation. • “ ” appears on the LCD. • POWERFUL operation ends in 20 minutes. Then the system automatically operates again with the previous settings which were used before POWERFUL operation.
Useful Functions ECONO / OUTDOOR UNIT QUIET Operation ECONO operation enables efficient operation by limiting the maximum power consumption. This function is useful to prevent the circuit breaker from tripping when the unit operates alongside other appliances on the same circuit. OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit by changing the frequency and fan speed of the outdoor unit.
TIMER Operation ON/OFF TIMER Operation Timer functions are useful for automatically switching the air conditioner on or off at night or in the morning. You can also use the ON TIMER and OFF TIMER together. [ON TIMER with a 24 hour clock display] (24 HOUR ON/OFF TIMER) ...
Page 171
TIMER Operation [OFF TIMER with a 24 hour clock display] (24 HOUR ON/OFF TIMER) To set • Check that the clock is correct. If not, set the clock to the present time. Page 11 Press “ ” appears on the LCD. “ ...
Page 172
TIMER Operation ON/OFF TIMER Operation [ON/OFF TIMER with an hours remaining display] (COUNT UP-DOWN ON/OFF TIMER) • Check that the clock is correct. If not, set the clock to the present time. Page 11 Press and hold for about 5 seconds, when signal indicater ( ) blink, release your finger from the button.
TIMER Operation WEEKLY TIMER Operation Up to 4 timer settings can be saved for each day of the week. This is convenient to adapt the WEEKLY TIMER to your family’s life style. Setting example of the WEEKLY TIMER The same timer settings are used from Monday through Friday, while different timer settings are used for the weekend. [Monday] Make timer settings for programmes 1-4.
Page 174
TIMER Operation WEEKLY TIMER Operation To use WEEKLY TIMER operation Setting mode • Make sure the day of the week and time are set. If not, set the day of the week and time. Page 11 Programme 1 Programme 2 Programme 3 Programme 4 [Monday] 25.0°C...
Page 175
TIMER Operation Press to select the desired time. • The time can be set between 0:00 and 23:50 in 10-minute intervals. • To return to the ON/OFF TIMER mode setting, press • Proceed to STEP when setting the OFF TIMER. Press •...
Page 176
TIMER Operation WEEKLY TIMER Operation Copy mode • A reservation made once can be copied to another day of the week. The whole reservation of the selected day of the week will be copied. Programme 1 Programme 2 Programme 3 Programme 4 [Monday] 25.0°C...
Page 177
TIMER Operation Confirming a reservation • The reservation can be confirmed. Setting Displays Normal Confirmation Press • The day of the week and the reservation number of the current day will be displayed. Press to select the day of the week and the reservation number to be confirmed.
Page 178
TIMER Operation WEEKLY TIMER Operation To delete a reservation An individual reservation Press • The day of the week and the reservation number will be displayed. Press to select the day of the week and the reservation number to be deleted. Press •...
• Before downloading the application software for installation, please read ‘‘Configuration” on Page 7 For Android phones 1) Open [Google Play]. 2) Search using the application name: [DAIKIN Mobile Controller]. 3) Follow the on-screen instructions for installation. For iOS phones 1) Open [App Store]. 2) Search using the application name: [DAIKIN Mobile Controller].
Page 180
System control via Smart Control Wireless LAN connection Enabling/disabling the wireless LAN connecting adapter To enable While operation is stopped, press and hold the button for 5 seconds. • “ ” appears on the LCD. • “ ” (SP menu) blinks. Press and select SP menu .
Page 181
NOTE. Press to return to the default screen. Connect your smart phone to your home network. Open the Home screen of the DAIKIN Mobile Fig. 1 Controller application. The air conditioner will be listed there (Fig. 1). NOTE Note on simple connection (WPS connection) •...
Page 182
• The wireless LAN connecting adapter lamp (orange) stays lit. If you fail to connect, refer to NOTE. Connect your smart phone to your home network. Open the Home screen of the DAIKIN Mobile Controller application. The air conditioner will be listed there.
Care Care and Cleaning CAUTION • Before cleaning, be sure to stop the operation and turn off the circuit breaker. • Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury. ...
Page 184
Care Care and Cleaning Air filter Open the front panel. Wash the air filters with water or clean them with • Hold the front panel by the sides and open it. vacuum cleaner. Backside of the front panel • It is recommended to clean the air filters every 2 weeks.
Page 185
Care Filter (small) * For the applicable filter type, please refer to Page 38 Attaching Clean or replace. [Cleaning] Open the front panel and pull out the air filters. Deodorizing filter (enzyme blue) : Blue Page 39 / Titanium apatite deodorizing filter : Insert the filter.
Page 186
Care Care and Cleaning Prior to a long period of non-use Operate the MOLD PROOF mode. Page 17 After operation stops, turn off the circuit breaker for the room air conditioner. Clean the air filters and reattach them. Page 39 To prevent battery leakage, take out the batteries from the remote controller.
When the Need Arises Indoor unit The flaps do not start swinging immediately. • The air conditioner is adjusting the position of the flaps. The flaps will start moving soon. The air conditioner stops generating Commonly occurring sounds. airflow during HEAT operation. ...
When the Need Arises Troubleshooting Before making an inquiry or a request for repair, please check the following. If the problem persists, consult your dealer. Not a problem Check This case is not a problem. Please check again before requesting repairs. Air conditioner The air conditioner does not operate Case...
Page 189
When the Need Arises Air conditioner Mist comes out Case Description / what to check • This happens when the air in the room is cooled into mist by the cold airflow during COOL Mist comes out of the indoor unit. or other operation.
Page 190
• Refer to the FAQ on: None of the above work. http://www.daikinthai.com/product/dmobile For instructions about how to operate the DAIKIN Mobile Controller application, please refer to the operation manual at http://www.daikinthai.com/product/dmobile Call your dealer immediately WARNING When an abnormality (such as a burning smell) occurs, stop operation and turn off the circuit breaker.
Page 191
When the Need Arises Fault diagnosis by remote controller • In case the air conditioner is malfunctioning, you can check the error code via the remote controller before consulting with service personnel and informing them of the malfunction code. When is held down for about 5 seconds, “...
Page 192
Quick Reference On/Off Temp Mode Swing MODE The two-dimensional bar code is a manufacturing code. 3P651499-2 M21N018 (2106) HT...