6. ENVIRONMENT
Operating Temperature: 0~35°C (Ambient)
Operating Humidity: 10%~90% (Non-condensing)
Operating Altitude: 0 - 14,000 feet (Non-Operating)
7. Dimensions (Physical dimension)
Height
Width
Depth
8. Weight (Physical weight)
a. Net:
23.0± 1kg (without Base)
25.0± 1kg (with Base)
b. Gross:
32± 1kg
9. Precautions
Please pay attention to the followings when you use this TFT LCD module.
9-1. Mounting Precautions
(1) You must mount a module using holes arranged in four cornersor four sides.
(2) You should consider the mounting structure so that uneven force (ex. Twisted
stress) is not applied to the module. And the case on which a module is mounted
should have sufficient strength so that external force is not transmitted directly to
the module.
(3) Please attach the surface transparent protective plate to the surface in order to
protect the polarizer. Transparent protective plate should have sufficient strength
in order to the resist external force.
(4) You should adopt radiation structure to satisfy the temperature specification.
(5) Acetic acid type and chlorine type materials for the cover case are not desirable
because the former generates corrosive gas of attacking the polarizer at high
temperature and the latter cause circuit broken by electro-chemical reaction.
(6) Do not touch, push or rub the exposed polarizers with glass, tweezers or
anything harder than HB pencil lead. And please do not rub with dust clothes
CONFIDENTIAL – DO NOT COPY
Display
Display Module +
Module
848.6
1458.6
69.9
(Unit: mm)
Base
890.5
1458.6
348.7
Page 2-2
File No. SG-0000244