PK-93393-10-00-2C
WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-
operated appliance.
• For Hi-lume
or Eco-10™ (EcoSeries) electronic ballast applications, use instruction sheet that comes with the dimmer for multi-location applications.
®
• Vizia™ remotes are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ devices for multi-location switching.
• Use only Vizia Coordinating Remotes with Vizia RF devices
Tools needed to install your Remote:
Slotted/Phillips Screwdriver
Electrical Tape
Pliers
Pencil
Cutters
Ruler
Changing the color of your Remote:
Your Remote may include three color options. The Remote ships
with the White frame attached. To change color of frame, proceed
as follows:
Line up tabs and press
push in side at tab
in side to attach
to release
INSTALLING YOUR REMOTE
NOTE: Use check boxes
when Steps are completed.
WARNING:
TO AvOID fIRE, ShOCk, OR DEATh;
Step 1
TURN Off pOWER at circuit breaker or fuse and test
that power is off before wiring!
Identifying your wiring application (most
Step 2
common):
NOTE: If the wiring in the wall box does not resemble
any of these configurations, consult a qualified
electrician.
1
2
1
3
2
3
4
4
5
5
6
3-Way
4-Way
1. Line or Load (See important
1. First Traveler – note color
instruction below)
2. Second Traveler – tagged
2. Neutral
3. Neutral
3. Ground
4. Ground
4. First Traveler – note color
5. Third Traveler – note color
5. Second Traveler – note color
6. Fourth Traveler – tagged
NOTE: For matching remote
NOTE: For matching remote
w/LEDs installation, the first
w/LEDs installation, the first
Traveler becomes Line Hot.
Traveler becomes Line Hot.
IMpORTANT:
for 3-Way applications, note that one of the screw terminals from
the old switch being removed will usually be a different color (Black)
or labeled Common. Tag that wire with electrical tape and identify
as the common (Line or Load) in both the dimmer wall box and
remote wall box.
for 4-Way applications, note that the old switch being removed
will have 4 screws plus a ground screw. Tag the two same color
insulated wires with electrical tape.
preparing and connecting wires:
Step 3
This remote can be wired using side wire terminal
screws or through backwire openings. Choose
appropriate wire stripping specifications accordingly.
Cut
(if necessary)
Cat. No. VZØØR-10, Coordinating Dimmer Remote (For use with Vizia and Vizia RF devices)
Cat. No. VZØØR-1L, Matching Dimmer Remote (For use with Vizia devices only)
Cat. No. VZØSR-10, Coordinating Switch Remote (For use with Vizia and Vizia RF devices)
Cat. No. VZØSR-1L, Matching Switch Remote (For use with Vizia devices only)
Step 2 cont'd
Strip Gage (measure
bare wire here or
use gage on back of
5/8"
(1.6 cm)
the dimmer)
Side Wire Connection
Side wire terminals accept
#14 AWG solid copper wire
only.
Strip Gage (measure
bare wire here or
use gage on back of
5/8"
(1.6 cm)
the dimmer)
Back Wire
(either hole may be used)
Back wire openings use
#14-12 AWG solid copper wire
only.
• Make sure that the ends of the wires from the wall box are straight
(cut if necessary).
• Remove insulation from each wire in the wall box as shown.
3-Way Wiring with Matching Remote (w/LEDs)
Step 4a
Application:
NOTE: Incandescent and Magnetic Low-Voltage
installations only.
NOTE: Matching remotes are for use with non RF devices
only. NOTE: Screw terminal dimmer depicted.
Matching Remote
Dimmer
Additional
Terminal
Screw marked
Neutral Wire
White (Wh)
4
2
Terminal
1
Screw marked
2
Black (Bk)
4
3
3
Terminal
1
Screw marked
5
5
Yellow/Red
(YL/RD)
Matching Remote (no LEDs)
Dimmer
Wh
Bk
hot (Black)
Bk
Green
Green
Ground
Ground
Black
YL/RD
RD
YL/RD
Line
Load
120vAC, 60hz
White
Neutral (White)
NOTE: The dimmer must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box with
a Line Hot connection and a Neutral connection. A Neutral wire to the
matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a
qualified electrician.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft.
Wiring Matching Remote (wall box with Line hot
connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch and First Traveler to dimmer terminal screw marked "BK"
or the Black dimmer lead.
• Second Traveler wall box wire from dimmer to remote terminal
screw marked "YL/RD" (note wire color). This traveler from the
remote must go to the terminal screw on the dimmer marked "YL/
RD" or the Yellow/Red dimmer lead.
• Line Neutral wall box to remote terminal screw marked "WH".
Wiring Dimmer (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw or
Green dimmer lead.
• Load wall box wire identified (tagged) when removing old switch to
dimmer terminal screw marked "RD" or the Red dimmer lead.
• First Traveler Line Hot to dimmer terminal screw marked "BK" or the
Black dimmer lead.
• Remove Red insulating label from terminal screw marked "YL/RD"
or Yellow/Red dimmer lead.
• Second Traveler wall box wire (note color as above) to dimmer
terminal screw marked "YL/RD" or the Yellow/Red dimmer lead.
This traveler from the dimmer must go to the terminal screw on the
remote marked "YL/RD".
• proceed to Step 6.
3-Way or More Applications (Multi-location)
Device Remotes
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS:
• Use only one (1) Vizia™ dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s)
will turn the light on at the brightness level selected at the dimmer.
• Recommended minimum wall box depth is 2-1/2".
• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m).
• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
3-Way Wiring with Coordinating Remote (no LEDs)
Step 4b
Application:
NOTE: Incandescent and Magnetic Low-Voltage
installations only. NOTE: Screw terminal dimmer
depicted.
Coordinating Remote
Dimmer
Terminal
1
1
2
Screw marked
2
Black (Bk)
3
3
4
Terminal
4
Screw marked
Yellow/Red
5
5
(YL/RD)
Terminal
Screw marked
Red (RD)
Dimmer
Coordinating Remote (no LEDs)
not used
hot (Black)
Bk
Wh
Bk
Green
Black
Green
Ground
Ground
RD
YL/RD
RD
YL/RD
Line
Load
120vAC, 60hz
White
Neutral (White)
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
NOTE: When using the coordinating remote without LEDs, the dimmer
can be installed on either the Line or Load side of the 3-way circuit.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw or
Green dimmer lead.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch to dimmer terminal screw marked "BK" or Black dimmer
lead.
• First Traveler wall box wire to terminal screw marked "RD" or Red
dimmer lead (note wire color). This traveler from the dimmer must
go to the terminal screw on the remote marked "RD".
• Remove Red insulating label from terminal screw marked
"YL/RD" or Yellow/Red dimmer lead.
• Second Traveler wall box wire to terminal screw marked "YL/RD" or
Yellow/Red dimmer lead (note wire color). This traveler from the
dimmer must go to the terminal screw on the remote marked "YL/RD".
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE: Maximum wire length from dimmer to last remote is
300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw.
• Load wall box wire identified (tagged) when removing old switch to
terminal screw marked "BK".
• First Traveler wall box wire (note color as above) to terminal screw
marked "RD". This traveler from the remote must go to the terminal
screw on the dimmer marked "RD" or Red dimmer lead.
• Second Traveler wall box wire (note color as above) to terminal
screw marked "YL/RD". This traveler from the remote must go to
the terminal screw on the dimmer marked "YL/RD" or Yellow/Red
dimmer lead.
• Remote terminal screw marked "WH" should have White insulation
label affixed.
NOTE: If insulating label is not affixed to terminal screw marked
"WH", use electrical tape to cover.
• proceed to Step 6.
3-Way Wiring with Matching Remote (w/
Step 4c
LEDs) for Controls with Neutral Connection
Application:
NOTE: Electronic Low-Voltage, Mark 10™, Quiet Fan
Speed and Electronic Switch installations only.
NOTE: Matching remotes are for use with non RF devices
only. NOTE: Dimmer is depicted.
Matching Remote
Control
Green
Terminal
Additional
Screw marked
Neutral Wire
White (WH)
Black
4
2
1
Terminal
2
Screw marked
White
4
Black (BK)
3
3
1
Red
5
5
Terminal
Yellow/Red
Screw marked
Yellow/Red
(YL/RD)
Mat hing Remote (w/LEDs)
c
Control
WH
BK
White
Black
Hot (Black)
Green
Green
Ground
Ground
Black
YL/RD
Red
Yellow/Red
Line
Load
120VAC, 60Hz
White
Neutral (White)
NOTE: The control must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box with
a Line Hot connection and a Neutral connection. A Neutral wire to the
matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a
qualified electrician.
NOTE: Maximum wire length from control to all installed remotes
cannot exceed 300 ft (90 m).
WIRING MATChING REMOTE (wall box with Line hot
connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch and First Traveler to terminal screw marked "BK" or Black
dimmer lead.
• Second Traveler wall box wire from control to remote terminal screw
marked "YL/RD" (note wire color). This traveler from the remote
must go to terminal screw marked "YL/RD" or Yellow/Red control
lead.
• Line Neutral wall box to remote terminal screw marked "WH".
WIRING DIMMER (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw or
Green control lead.
• Load wall box wire identified (tagged) when removing old switch to
terminal screw marked "RD" or
Matching Remote
Red control lead.
(3-Way Wall box from Step 2)
• First Traveler Line Hot to terminal
Terminal
screw marked "BK" or Black
Screw marked
White (Wh)
control lead.
2
• Remove Red insulating label from
Terminal
terminal screw marked "YL/RD" or
1
Screw marked
Black (Bk)
4
Yellow/Red control lead.
3
• Second Traveler wall box wire
Terminal
Screw marked
(note color as above) to terminal
Yellow/Red
5
(YL/RD)
screw marked "YL/RD" or Yellow/
Red control lead. This traveler
from the control must go to the
terminal screw on the remote marked "YL/RD".
• Line neutral wall box wire to terminal screw marked "WH" or
White control lead.
• proceed to Step 6.
hot (Black)
3-Way Wiring with Coordinating Remote (no
Step 4d
LEDs) for Controls with Neutral Connection
Line
Application:
120vAC, 60hz
NOTE: Electronic Low-Voltage, Mark 10™, Quiet
Fan Speed and Electronic Switch installations only.
NOTE: Dimmer is depicted.
Neutral (White)
Coordinating Remote
Control
Terminal
Screw marked
White (WH)
Black
1
White
2
2
1
3
Green
4
3
5
Red
Terminal
4
Yellow/Red
Screw marked
Yellow/Red
5
(YL/RD)
Coo dinating Remote (no LEDs)
r
Control
WH
BK
White
Hot (Black)
Black
not used
Green
Black
Green
Ground
Ground
Yellow/Red
RD
Red
YL/RD
Line
not used
Load
120VAC, 60Hz
White
Neutral (White)
WIRING CONTROL:
Connect wires per WIRING DIAGRAM as follows:
NOTE: The control must be installed in a wall box that has a Line Hot
Connection.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw or
Green control lead.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch to terminal screw marked "BK" or Black control lead.
• First Traveler wall box wire to terminal screw marked "RD" or Red
control lead (note wire color).
• Remove Red insulating label from terminal screw marked "YL/RD"
or Yellow/Red control lead.
• Second Traveler wall box wire to terminal screw marked "YL/RD"
or Yellow/Red control lead (note wire color). This traveler from
the control must go to the terminal screw on the remote marked
"YL/RD".
• Line Neutral wall box wire to terminal screw marked "WH" or White
control lead.
Step 4d cont'd
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE: "BK" and "RD" terminals on coordinating remote are
unused. Tighten both screws.
NOTE: Maximum wire length from control to last remote is
300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw.
• Load wall box wire identified (tagged) when removing old switch
to First Traveler (note color as above).
• Second Traveler wall box wire (note color as above) to terminal
screw marked "YL/RD". This traveler from the remote must go to
the terminal screw marked "YL/RD" or Yellow/Red control lead.
• Remove White insulating label from terminal screw marked
"WH".
• Line Neutral wall box wire to terminal screw marked "WH".
• proceed to Step 6.
4-Way Wiring with Matching Remote (w/LEDs)
Step 5a
Application:
NOTE: Incandescent and Magnetic Low-Voltage
installations only.
NOTE: Matching remotes are for use with non RF
devices only.
NOTE: Screw terminal dimmer depicted.
Matching Remote
Dimmer
(3-Way Wall box from Step 2)
(4-Way Wall box from Step 2)
Terminal
Additional
Screw marked
Additional
Neutral Wire
White (Wh)
Neutral Wire
4
3
Terminal
1
Screw marked
2
Black (Bk)
5
3
4
Terminal
1
2
Screw marked
5
Yellow/Red
6
(YL/RD)
Matching Remote
Matching Remote
(w/LEDs)
(w/LEDs)
Dimmer
Wh
Wh
Bk
Bk
Bk
Green
Ground
Green
Green
Black
Ground
Ground
YL/RD
YL/RD
RD
YL/RD
Load
White
NOTE: The dimmer must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box
with a Line Hot connection and a Neutral connection. A Neutral wire
to the matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a
qualified electrician.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft (90 m).
WIRING MATChING REMOTE (4-Way wall box with Line
hot connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• First Traveler and Third Traveler wall box wire from dimmer in
the 3-way box to remote terminal screw marked "BK" in the
4-way box, and to the terminal screw marked "BK" of the
remaining remote in the 3-way box.
• Second Traveler (tagged) and Fourth Traveler (tagged) wall box
wire from dimmer in the 3-way box to remote terminal screw
marked "YL/RD" in the 4-way box, and to the terminal screw
marked "YL/RD" of the remaining remote in the 3-way box (note
wire colors). This traveler from the remotes must go to the
terminal screw on the dimmer marked "YL/RD" or the Yellow/Red
dimmer lead.
• Line Neutral wall box wire to remote terminal screw marked
"WH".
WIRING MATChING REMOTE (3-Way wall box with Line
hot connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identified (tagged) when
removing old switch and First Traveler dimmer terminal screw
marked "BK" or the Black dimmer lead.
• Second Traveler wall box wire from dimmer to remote terminal
screw marked "YL/RD" (note wire color as above). This traveler
from the remote must go to the terminal screw on the dimmer
marked "YL/RD" or the Yellow/Red dimmer lead.
• Line Neutral wall box wire to remote terminal screw marked
"WH".

Advertisement

loading

Summary of Contents for Leviton Vizia VZ00R-10X

  • Page 1 3-Way or More Applications (Multi-location) Device Remotes Cat. No. VZØØR-10, Coordinating Dimmer Remote (For use with Vizia and Vizia RF devices) Cat. No. VZØØR-1L, Matching Dimmer Remote (For use with Vizia devices only) Cat. No. VZØSR-10, Coordinating Switch Remote (For use with Vizia and Vizia RF devices) PK-93393-10-00-2C Cat.