SBS-VAR-18,24,30 LP or NG
SBS-IPI-18,24,30 LP or NG
SBSIII-MAN-18,24,30 LP or NG
SBSIII-REM-18,24,30 LP or NG
SBSIII-VAR-18,24,30 LP or NG
SBSIII-IPI-18,24,30 LP or NG
Check with your local building code agency before you begin installation to ensure compliance with local codes, including
the need for permits and follow-up inspections. If you encounter any problems regarding code approvals, or if you need
clarification of any of the instructions contained here, contact the Technical Services Dept., Heatmaster/American Gas Log,
LLC. 919-331-0078 or 919-331-0079.
Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING
If the information in these instruc-
tions is not followed exactly, a
fire may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas:
- Do not try to light any appliance.
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or
the gas supplier.
1
HEATMASTER
AMERICAN GAS LOG
DO NOT DISCARD THIS MANUAL
Read, understand
and follow these
instructions for safe
i n s t a l l a t i o n a n d
operation.
Heatmaster/American Gas Log, LLC • 16-1012 •Rev D. 03/2018
CAUTION
Leave this manual with
party responsible for
use and operation.
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
Glass and other surfaces are hot during
operation and cool down.
Keep children away.
CAREFULLY SUPERVISE children in same room as
appliance.
Alert children and adults to hazards of high
temperatures.
Keep clothing, furniture, draperies and other
combustibles away.
In the Commonwealth of Massachusetts:
This appliance must be installed by a licensed plumber
or gas fitter.
The chimney flue damper, when used with gas logs, will
be welded open or completely removed.
A CO detector shall be installed in the room where the
appliance is installed.
Installation
Instructions
Installation and service of this
appliance should be performed by
qualified personnel. Heatmaster/
American Gas Log, LLC suggests
NFI certified or factory-trained
professionals, or technicians
s u p e r v i s e d b y
an NFI certified
professional.
WARNING

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SBS-MAN-18LP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hearth & Home SBS-MAN-18LP

  • Page 1 Installation HEATMASTER Instructions AMERICAN GAS LOG Models: SBS-MAN-18,24,30 LP or NG SBS-REM-18,24,30 LP or NG Installation and service of this appliance should be performed by SBS-VAR-18,24,30 LP or NG qualified personnel. Heatmaster/ SBS-IPI-18,24,30 LP or NG American Gas Log, LLC suggests NFI certified or factory-trained SBSIII-MAN-18,24,30 LP or NG professionals, or technicians...
  • Page 2 Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. Congratulations Congratulations on selecting a Heatmaster/American Gas The information contained in this owner’s manual, unless Log, LLC gas log set—an elegant and clean alternative to noted otherwise, applies to all models and gas control burning wood.
  • Page 3: Design And Installation Considerations

    WARNING WARNING Improper installation, adjustment, alteration, service HOT! DO NOT TOUCH. or maintenance can cause injury or property damage. SEVERE BURNS MAY RESULT. Refer to the owner’s information manual provided with CLOTHING IGNITION MAY RESULT. this appliance. For assistance or additional information Glass and other surfaces are hot during consult a qualified installer, service agency or the gas operation and cool down.
  • Page 4: Gas Supply Connection

    • This appliance must have a screen in place while the WARNING appliance is in operation and, unless other provisions for combustion air are provided, the screen shall have an Fire Risk opening for introduction of combustion air. Explosion Risk •...
  • Page 5: Negative Pressure

    G. Negative Pressure WARNING Negative pressure results from the imbalance of air avail- able for the fireplace to operate properly. Causes for this Asphyxiation Risk imbalance include: This appliance produces carbon monoxide • Exhaust fans (kitchen, bath, etc.). (CO). • Range hoods.
  • Page 6: Inspect The Appliance And Components

    • IPI models include a battery box which holds 2 “D” size H. Inspect the Appliance and Components batteries. The battery box should be placed in the right front corner of your fireplace and covered with the log • Remove the contents from the burner box. Attached to cover as shown in Figure 3.
  • Page 7 I. For Natural Gas Installation • Pour sand into the burner pans to the point where the burner pipe is covered. See Figure 5. Level the sand from right to left to ensure an even flame pattern. At this point the pan should be half full. Be sure not to cover pilot assembly.
  • Page 8 J. For Propane Gas Installation Inspect the pilot burner to ensure it is clear of any • rock wool. • Remove the Platinum Bright Embers™ from the package. WARNING For optimum performance peel each piece apart in layers and lightly place on top of the vermiculite and rock wool Fire Risk where the flame is blue.
  • Page 9: Inspect The Venting System

    L. Inspect the Venting System CAUTION The fireplace venting system is designed and constructed to develop a positive flow adequate to remove flue gases to the After burning, the logs become fragile. Take care in outside atmosphere. See fireplace installation instructions. handling.
  • Page 10: Frequently Asked Questions

    O. Frequently Asked Questions Can I close the glass doors on my fireplace when using my gas logs? No. The gas log sets are designed for use in fireplaces with all fireplace doors fully opened. Operating your log set with the doors closed will cause overheating, premature failure of valve systems, and will void the warranty of your log set.
  • Page 11 P. Lighting Instructions • Remote Ready Valve (REM) FOR YOUR SAFETY READ BEFORE LIGHTING FOR YOUR SAFETY READ BEFORE LIGHTING WARNING! IF THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A.
  • Page 12: For Your Safety Read Before Lighting

    Q. Lighting Instructions • Safety Pilot Valve (MAN) FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot that must be lighted by hand. When lighting the pilot, follow these instructions exactly.
  • Page 13: Lighting Instructions (Ipi)

    • IPI Pilot Valve (IPI) R. Lighting Instructions FOR YOUR SAFETY READY BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an intermittent Pilot ignition (IPI) device which automatically lights the burner.
  • Page 14 Parts Diagram SBS BURNER SERIES Service Parts SBS Burner 18”, 24”, 30” SBSIII Burner 18”, 24”, 30” Heatmaster/American Gas Log, LLC • 16-1012 •Rev D. 03/2018...
  • Page 15 Manual Valve Assembly 18”,24”,30” REM Valve Assembly 18”,24”,30” 10 11 VAR Valve Assembly 18”,24”,30” IPI Valve Assembly 18”,24”,30” 10 & 11 Heatmaster/American Gas Log, LLC • 16-1012 • Rev D. 03/2018...
  • Page 16: Optional Accessories

    Service Parts SBS BURNER SERIES Description of Part 18” 24” 30” Qty. BPA-300-18 BPA-300-24 BPA-300-30 Burner Pan & Grate Assembly BPA-300-33 BPA-300-35 BPA-300-40 Three Tier Burner Pan & Grate Assembly FT-18 FT-24 FT-30 Connector 10-1065 10-1065 10-1065 Damper Clamp FOR MANUAL UNITS 07-1025 07-1025 07-1025...
  • Page 17: Warranty

    HEATMASTER AMERICAN GAS LOG Warranty DECORATIVE GAS LOG LIMITED WARRANTY Heatmaster/American Gas Log, LLC. extends the following warranty for decorative gas log sets as described herein, while it is in its location of original installation. Dealers and employees of Heatmaster/American Gas Log, LLC. have no authority to make any warranty or authorize any remedies in addition to or inconsistent with the terms of this Program.

Table of Contents