Power-saving mode (mode 2)

6.4
When M1 = 1 & M0 = 0, module works in mode 2
UART is closed, the module cannot receive any serial port data from outside MCU.
Transmitting
Hence the function of wireless transmission is not available for the module working in this mode.
In mode 2, it is required the data transmitter works in mode 1.
The wireless module monitors the preamble code at regular time.
Once it gets the preamble code, it will remain as receiving status and waiting for the completion of receiving the
entire valid data package.
Then the AUX outputs low level, 5ms later the serial port is open to transmit received wireless data through TXD.
Receiving
Finally, AUX outputs high level after process completed.
The wireless module stays in "power-saving – monitoring" working status (polling).
By setting different wake-up time, the module will have different receiving response delay (2s in maximum) and
average power consumption (30uA in minimum).
The user needs to achieve a balance between communication delay time & average power consumption.

6.5 Sleep mode (mode 3)

When M1=1, M0=1, module works in mode 3
Transmitting
N/A
Receiving
N/A
Parameter
This mode can be used for parameter setting. It uses serial port 9600 & 8N1 to set module working parameters through
setting
specific instruction format. (pls refer to parameters setting for details)
When the mode changes from stand-by mode to others, the module will reset its parameters, during which the AUX
Notes
keeps low level and then outputs high level after reset completed. It is recommended to check the AUX rising edge for
user.

7 Command format

In sleep mode(Mode 3:M1=1, M0=1), it supports below instructions on list.
(Only support 9600 and 8N1 format when setting)
Instruction
No.
C0+working
1
parameters
2
C1+C1+C1
C2+working
3
parameters
4
C3+C3+C3
5
C4+C4+C4
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
format
C0 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in total and
must be sent in succession, ( Save the parameters when power-down ).
( Save the parameters when power-down )
Three C1 are sent in hexadecimal format. The module returns the saved parameters and
must be sent in succession.
C2 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in total and
must be sent in succession. ( Do not save the parameters when power-down )
Three C3 are sent in hexadecimal format. The module returns the version information
and they must be sent in succession.