UNC100 Integra/Axiom Light Manual
2018-12-17– V1.3
UNC100 Integra/Axiom Light Hardware Manual V1.3
Page 1 of 21
RBH Access Technologies Inc.

Advertisement

Table of Contents
loading

Summary of Contents for RBH Access Technologies Integra 32 UNC100

  • Page 1 UNC100 Integra/Axiom Light Manual 2018-12-17– V1.3 UNC100 Integra/Axiom Light Hardware Manual V1.3 Page 1 of 21 RBH Access Technologies Inc.
  • Page 2: Copyright Notice

    Further RBH Access Technologies Inc. reserves the right to revise this publication, and to make changes to the content hereof from time to time, without the obligation of RBH Access Technologies Inc. to notify any person or organization of such revision or changes.
  • Page 3: Revision History

    -Changed graphic -Removed relevant information -Confirmed correct specifications Added ULC text. 08/06/14 Reconfigured order of pages. Minor editing of text. 11/17/16 Replaced UNC-100 Reader connection picture UNC100 Integra/Axiom Light Hardware Manual V1.3 Page 3 of 21 RBH Access Technologies Inc.
  • Page 4: Table Of Contents

    Door Contact (DC) ............................ 20 General Purpose ............................20 Access Point Operating Modes ........................20 High Security ............................20 Unlocked .............................. 20 Tamper ..............................20 Lockout Alarm ............................20 UNC100 Integra/Axiom Light Hardware Manual V1.3 Page 4 of 21 RBH Access Technologies Inc.
  • Page 5 Door Held Open Alarm ......................... 20 Keypad / Reader Combination ......................20 Access Granted ............................ 20 Access Denied ............................20 UNC100 Specification........................... 21 Cable Specification ............................21 UNC100 Integra/Axiom Light Hardware Manual V1.3 Page 5 of 21 RBH Access Technologies Inc.
  • Page 6: Unc-100 Graphics

    UNC-100 Graphics UNC100 Integra/Axiom Light Hardware Manual V1.3 Page 6 of 21 RBH Access Technologies Inc.
  • Page 7: Introduction

    Host Comms LED is a bicolour LED that turns red when receiving data from the host, and turns green when transmitting of data. The Run LED will flash slowly when connected to the host and quickly when not connected. UNC100 Integra/Axiom Light Hardware Manual V1.3 Page 7 of 21 RBH Access Technologies Inc.
  • Page 8: Tamper Detection

    IOC8 This selection is used to connect the UNC100 with up to four IOC8 boards and can not be used for connection with other Integra panels. UNC100 Integra/Axiom Light Hardware Manual V1.3 Page 8 of 21 RBH Access Technologies Inc.
  • Page 9: Dip Switch Settings

    DIP switch 5 up will enables Ethernet Secure Mode. This will prevent access to the controller’s programming through the Ethernet. UNC100 Integra/Axiom Light Hardware Manual V1.3 Page 9 of 21 RBH Access Technologies Inc.
  • Page 10: Rs485 Port Baud Rate Selection

    For ULC-S319-05 III compliance, all wiring into the panel’s cabinet must enter through metal conduit. Also be sure to mount the panel in a protected area. Name Defaults Description and notes UNC100 Integra/Axiom Light Hardware Manual V1.3 Page 10 of 21 RBH Access Technologies Inc.
  • Page 11: Integra™ Network

    URC2000 panels may also be used in place of IRC-2000 panels. Note: When UNC100 panels are used in conjunction with IRC2000 and URC2000 panels the last panel in the line must be terminated. UNC100 Integra/Axiom Light Hardware Manual V1.3 Page 11 of 21 RBH Access Technologies Inc.
  • Page 12: Unc100 & Ioc8 Connection

    The other version with the four programable inputs and four outputs, two open collector and two form C relays. Both can be wired to the UNC100 on the same RS485 port. UNC100 Integra/Axiom Light Hardware Manual V1.3 Page 12 of 21 RBH Access Technologies Inc.
  • Page 13 For details on Input (I/P) wiring see page Input (I/P) Circuit Types18. For details on Output (O/P) wiring see page UNC100 Integra/Axiom Light Hardware Manual V1.3 Page 13 of 21 RBH Access Technologies Inc.
  • Page 14: Rs485 Configuration

    IOC8 boards and will not connect to any other Integra panels. Note: The UNC100 will connect to either other Integra panels or to IOC8 boards, not both. UNC100 Integra/Axiom Light Hardware Manual V1.3 Page 14 of 21 RBH Access Technologies Inc.
  • Page 15: Reader Interface

    For ULC-S319-05 III compliance, all wiring into the panel’s cabinet must enter through metal conduit. Also be sure to mount the panel in a protected area. Reader wire colours may vary for different reader manufactures. Please verify your wiring. UNC100 Integra/Axiom Light Hardware Manual V1.3 Page 15 of 21 RBH Access Technologies Inc.
  • Page 16: Outputs

    Connect the diode cathode (end with band) to the positive terminal and the other end to the negative terminal. The diode must be placed at the device being switched and not at the controller. UNC100 Integra/Axiom Light Hardware Manual V1.3 Page 16 of 21 RBH Access Technologies Inc.
  • Page 17: Output Operation

    For ULC-S319-05 III compliance, all wiring into the panel’s cabinet must enter through metal conduit. Also be sure to mount the panel in a protected area. UNC100 Integra/Axiom Light Hardware Manual V1.3 Page 17 of 21 RBH Access Technologies Inc.
  • Page 18: Supervised Inputs

    Open Circuit Trouble This circuit provides a high degree of supervision and detects both short and open circuit fault conditions. Use this circuit in high security applications. UNC100 Integra/Axiom Light Hardware Manual V1.3 Page 18 of 21 RBH Access Technologies Inc.
  • Page 19: Input Applications

    A normally open or normally closed button can be used and the circuit type can be programmed from the PC. Activating the RTE input will unlock the door. The RTE can be disabled by time zone. UNC100 Integra/Axiom Light Hardware Manual V1.3 Page 19 of 21 RBH Access Technologies Inc.
  • Page 20: Door Contact (Dc)

    For ULC-S319-05 III compliance, all wiring into the panel’s cabinet must enter through metal conduit. Also be sure to mount the panel in a protected area. UNC100 Integra/Axiom Light Hardware Manual V1.3 Page 20 of 21 RBH Access Technologies Inc.
  • Page 21 20 to 22 AWG, 6 or 8-conductor, 500 feet (150 meters) stranded, shielded (not twisted) Input / Output Port Circuit Loop 2-conductor, 20 to 22 AWG 1000 feet (300 meters) UNC100 Axiom Hardware Manual V1.1 Page 21 of 21 RBH Access Technologies Inc.