Preparing The Icemaker For Periods Of Non-Use - Hoshizaki KMS-822MLJ Instruction Manual

Modular crescent cuber, condensing unit
Hide thumbs Also See for KMS-822MLJ:
Table of Contents

Advertisement

IV. Preparing the Icemaker for Periods of Non-Use
• When storing the icemaker for an extended time or in sub-freezing temperatures,
follow the instructions below to prevent damage.
• To prevent damage to the water pump seal, do not leave the control switch in the
"WASH" position for extended periods when the water tank is empty.
When the icemaker is not used for two or three days under normal conditions, it is sufficient
to move the control switch to the "OFF" position. When storing the icemaker for an extended
time or in sub-freezing temperatures, follow the instructions below.
1. Remove the water from the icemaker water supply line:
1) Turn off the power supply and remove the front panel.
2) Close the icemaker water supply line shut-off valve and open the icemaker water supply
line drain valve.
3) Allow the line to drain by gravity.
4) Attach a compressed air or carbon dioxide supply to the icemaker water supply line
drain valve.
5) Make sure at least 3 minutes have elapsed since you turned off the power supply. Make
sure the control switch is in the "ICE" position. Replace the front panel in its correct
position and turn on the power supply.
6) Blow the icemaker water supply line out using the compressed air or carbon dioxide
supply.
7) Close the icemaker water supply line drain valve.
2. Drain the water tank:
1) Turn off the power supply.
2) Remove the front panel, then move the control switch to the "OFF" position.
3) Remove the insulation panel. Remove cube guide B, then remove cube guide A. See
Fig. 14. Remove the overflow cap, overflow pipe, and water shield.
4) Remove the drain plug. Allow the water tank to drain, then replace the drain plug in its
correct position. Be careful not to cross thread it.
5) Replace the water shield, overflow pipe, overflow cap, cube guide A, cube guide B, and
insulation panel in their correct positions. Be careful not to cross thread the overflow
pipe.
6) Remove all ice from the dispenser unit/storage bin. Clean the dispenser unit/storage bin
using a neutral cleaner. Rinse thoroughly after cleaning.
7) Replace the front panel in its correct position.
NOTICE
30

Advertisement

Table of Contents
loading

This manual is also suitable for:

Serenity seriesSrk-10j

Table of Contents