Page 1
AirHarmony-4200 DC Installation Guide Internal Filters Part Number: UGD-D01196 System Release: 16.0 Revision: A6 Published: September 2020...
Page 2
Airspan Networks Ltd. reserves the right, without prior notice or liability, to make changes in equipment design or specifications. Information supplied by Airspan Networks Ltd. is believed in good faith to be accurate and reliable, while every care has been taken in preparing these documents. However, Airspan Networks Ltd. does not make any representations and gives no warranties of whatever nature in respect of these documents, including without limitation, the accuracy or completeness of any information, facts and/or opinions contained therein.
DECLARATION OF CONFORMITY ..................8 GPS Compliance......................10 Maximum Output TX Total Power ..............10 Power Consumption - Supply and Current ..............10 Antenna System ......................12 External Antenna ......................12 About This Document ..................13 UGD-D01196 Airspan Commercial and Internal Use...
Page 4
Document Conventions ....................13 Document Organization ....................14 Related Reading......................14 Customer Care Help Desk ................15 Airspan Encourages Comments ..................15 1 Introduction ....................16 1.1 AirHarmony-4200 DC Internal Filters ............... 16 1.2 Deployment ......................17 1.3 Related AirHarmony 4200 DC Internal Filters Variants..........18 2 Getting Started ....................
Page 5
Figure 15: AirHarmony mounted on concrete Pole ................33 Figure 16: AirHarmony mounted Wooden Pole................34 Figure 17: AirHarmony mounted on a Wall ..................35 Figure 18: Grounding ........................36 Figure 19: Gland connector - copper ....................38 UGD-D01196 Airspan Commercial and Internal Use...
Page 6
Table 7. Parts & Kits......................... 21 Table 8: AirHarmony-4200 DC Physical Dimensions ................. 24 Table 9: AirHarmony-4200 DC Environment Compliance ..............25 Table 10: AC/DC Converter Specifications ..................43 Table 11: Job Sheet.......................... 44 UGD-D01196 Airspan Commercial and Internal Use...
Abstract This document details procedures for installing the Airspan’s AirHarmony-4200 DC, with internal filters, a mini-Macro class eNodeB variant and its place in the Airspan product suite. This document is intended for qualified personnel with a working knowledge of LTE.
Connect the equipment to an outlet on a circuit different from that to which the power source is connected Modifications Any changes and modifications to this device that are not expressly approved by Airspan Networks may void the user's authority to operate the equipment. General ...
Toute enfreinte a ces obligations peut annuler la garantie délivrée par Airspan pour ces produits et peut exposer l’utilisateur final ou le fournisseur de services a des dommages légaux et financiers.
Déconnecter le produit de la source d’alimentation avant nettoyage. L’unité ne doit pas être située trop près de lignes électriques ou autres circuits de puissance, avec lesquels il pourrait entrer en contact. UGD-D01196 Airspan Commercial and Internal Use...
Substances Hazardous to Health Regulations 1989 and the Dangerous Substances Regulations 1990). At the end of any Airspan products life cycle, the customer should consult with Airspan to ensure that the product is disposed of in conformance with the relevant regulatory requirements.
- Use shielded out CAT5e (minimum) cabled terminated with metallic RJ45 connectors. - In order to protect the indoor unit, install surge protection circuits on all copper cables on their entrance to the building. - Surge protection circuit must use a minimum 16AWG grounding cable. UGD-D01196 Airspan Commercial and Internal Use...
This equipment is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. Español: Por medio de este Airspan, declara que la unidad cumple con los requisitos esenciales y cualquier otra disposición aplicable o exigible de la Directiva 2014/53 / UE. Greek: ΜΕ...
Page 15
Därmed intygar Airspan att denna enhet överensstämmer med de väsentliga egenskapskraven och andra relevanta bestämmelser som anges i direktiv 2014/53 / EU. Íslenska: Airspan lýsir hér með yfir að þessi eining uppfylli grunnkröfur og aðrar kröfur tilskipunar 2014/53 / ESB. Norsk: Airspan erklærer herved at utstyrsenheten oppfyller grunnleggende krav og andre relevante krav i...
Note: A GPS is recommended for synchronizing between LTE sectors. Note: An optional GPS Lightning/Surge protector is available from Airspan when installing the GPS antenna in a remote location for lightning prone deployments. Maximum Output TX Total Power Table 1: AirHarmony-4200 DC Internal Filter FCC Maximum Output TX Total Power...
Transient Voltage: +150V (ETR283) The use of other power sources may impair safety AC power feed is also available, using an AC/DC power converter offered by Airspan. Note: For more details on the offered AC/DC converter (sold separately), please contact your nearest Airspan sales representative.
Antenna Gain (dBi) Type 3300MHz – 3800MHz Dual Port, Omni, +/-45⁰Polarisation, Fixed Tilt Note: For a list of compatible external antennas, please contact your nearest Airspan Sales representative. Figure 1: AirHarmony-4200 DC Internal Filters UGD-D01196 Airspan Commercial and Internal Use...
AirHarmony-4200 DC (Internal Filters) Installation Guide About This Document Purpose This guide provides the workflow and step-by-step procedures for installing the Airspan’s AirHarmony-4200 DC Internal Filters Macro-class eNodeB variant. These procedures include: Verify prerequisites Mount GPS Install Mounting bracket ...
Provides information that aids users in performing the installation. Abbreviations Lists the abbreviations used in this document and their expansions. Related Reading The following documents contain related information: AirHarmony-4200 Hardware Product Specification Airspan LTE Commissioning Manual UGD-D01196 Airspan Commercial and Internal Use...
Customer Care Help Desk Airspan’s Customer Care Help Desk offers prompt and efficient customer support services. Note: To avail Airspan’s Customer Care Help Desk support, you must be a registered user and must have a valid support contract. To register, click here and fill the Registration form.
AirHarmony-4200 DC (Internal Filters) Installation Guide 1 Introduction This section provides a descriptive overview of the Airspan’s AirHarmony-4200 DC Internal Filters a Macro-class eNodeB variant and its place in the Airspan product suite. This document is intended for readers with LTE working knowledge.
Required - circuit breaker for AC power source (when used) -16A for EU installation and 20A for US installation. Warning: Required - circuit breaker for DC power source (when used). Maximum 10A. Figure 2: AirHarmony-4200 DC Internal Filters unit UGD-D01196 Airspan Commercial and Internal Use...
The Workflow to install the AirHarmony-4200 DC Internal Filters is displayed in the following diagram: Figure 3: Workflow Caution: Antennas must be connected and attached before AirHarmony-4200 DC Internal Filters unit is powered on. UGD-D01196 Airspan Commercial and Internal Use...
Verify the Tools Table 7. Minimum Hardware Requirements Tool #13 wrench for securing the M8 Hex Head bolts on the Pole/wall mount 1/2” Socket Wrench For 5/16” Hex head (Lag) bolts when wall mounting UGD-D01196 Airspan Commercial and Internal Use...
4 bands for pole mounting – mounting kit supports dia. Range 64 mm (2.5 in) > 362 mm (14.25 in) Optional AC / DC Power Converter – Available from Airspan AC/DC Power Converter for AC/DC Indoor AC-DC-IDU- 133-00-061...
Page 28
100m, Outdoor LC/DPX to LC, IP67 Full AXS SM FIB-FA-150-LC- 686-00-013 Fiber Cable SM-1 150m, Outdoor LC/DPX to LC, IP67 Full AXS SM FIB-FA-200-LC- 686-00-014 Fiber Cable SM-1 200m, Outdoor LC/DPX to LC, IP67 UGD-D01196 Airspan Commercial and Internal Use...
AirHarmony-4200 DC (Internal Filters) Installation Guide Panels The following figures display the AirHarmony-4200 DC Internal Filters bottom and top panels. The following displays the AirHarmony-4200 DC’s bottom panel. Figure 4: AirHarmony-4200 DC Internal Filters Unit, Bottom panel UGD-D01196 Airspan Commercial and Internal Use...
Dimensions (H x W x D) AirHarmony-4200 DC Internal Filters 509 x 236 x 210 mm / 20.0 x 9.3 x 8.3 in. Weight Main Unit 20 Kg / 44 Lbs. Universal mounting bracket 3 Kg / 6.6 Lbs. UGD-D01196 Airspan Commercial and Internal Use...
Rain and dust ingress IP66 protection 70-106 kPa as well as: Operational altitude ETSI 300 019 1-4 From -60m to 1800m @ 40C From 1800m to 4200m @ 30C Solar radiation 1120 W/m ETSI 300 019 1-4 UGD-D01196 Airspan Commercial and Internal Use...
It is good practice to weather-proof all the antenna connections. This is done with a layer of self-amalgamating tape followed by an over layer of PVC tape. The weather- proofing the GPS connection is best done at this stage to give easier access to the connections. UGD-D01196 Airspan Commercial and Internal Use...
Insert the clamp straps (supplied) through the slots in the mounting plate passing them through the pole clamps. Insert the clamp bands by passing them through the slots in the mounting plate, in four (4) places. Tighten the clamp bands with large flat screwdriver. UGD-D01196 Airspan Commercial and Internal Use...
AirHarmony-4200 DC (Internal Filters) Installation Guide Figure 8: Mounting plate mounted Mounting on a Wooden Pole Airspan provides an additional mounting alternative specifically for a wooden pole. The following images show the pole mount assembly on a wooden pole. Caution: Take care to install the Pole/Wall mounting plate in the correct orientation.
Determine where to position the mounting plate on the pole and mark where to drill for insertion of the 3/8-16 through-bolt. Note: Threaded rod and necessary hardware are not supplied by Airspan and are the responsibility of the installer. Drill a minimum 7/16” hole to accept the 3/8-16 threaded rod.
Attach the mounting plate to the wall using Lag bolts (x8 recommended). Note: Lag bolts (x8) and necessary hardware are not supplied by Airspan and are the responsibility of the installer. Recommended minimum 5/16 x 4” dia. (8mm x 100mm) with appropriate plugs according to field conditions.
(studs) on the top of the mounting plate. Figure 13: Lift unit and fit the slotted holes unto studs on top of mounting plate The following displays a close up of the Pin (stud) alignment. Figure 14: Align Pins UGD-D01196 Airspan Commercial and Internal Use...
Once aligned insert the supplied M8x20 Hex head bolt with a split washer and a flat washer into each clinch-nut. Check and tighten all six (6) M8x20 Hex head bolts. The following displays the AirHarmony-4200 DC being mounted on a non-wooden pole. Figure 15: AirHarmony mounted on concrete Pole UGD-D01196 Airspan Commercial and Internal Use...
AirHarmony-4200 DC (Internal Filters) Installation Guide The following displays the AirHarmony-4200 DC mounted on a wooden pole. Figure 16: AirHarmony mounted Wooden Pole UGD-D01196 Airspan Commercial and Internal Use...
AirHarmony-4200 DC (Internal Filters) Installation Guide The following displays the AirHarmony-4200 DC mounted on a wall. Figure 17: AirHarmony mounted on a Wall UGD-D01196 Airspan Commercial and Internal Use...
10.0 Nm (1.47 lb-ft). RF failures can result when the RF connector is over-tightened. Connecting RF Jumper Cables to External Antenna The following describes how to connect the antenna cables to the External Duplexers. UGD-D01196 Airspan Commercial and Internal Use...
The following demonstrates the recommended assembly instructions, hardware and tool requirements for the proper Ethernet cable assembly of the Ethernet Category 5e (enhanced) (CAT5e) cable used by Airspan products. The Ethernet cable is connected using a standard RJ45 connector protected by a harsh environment protective casing.
AirHarmony -4200 DC using an outdoor fiber cable. The optical connection enables a one-hand installation of the connector. This enables the users to easily remove and replace the SFP transceiver module which eliminates the need to open the unit and expose its contents to hazardous weather conditions. UGD-D01196 Airspan Commercial and Internal Use...
AirHarmony-4200 DC (Internal Filters) Installation Guide Note: Airspan recommends using the Finisar - FTLF1318P3BTL 1000BASE-LX which has been tested and approved by Airspan. Available from Airspan if required. SFP Cable Connection Figure 21: LC duplex cable assembly Remove the protective dust cap from the connector housing assembled on the unit.
The shell should be hand tightened only. Do NOT use tools to tighten the shell. Once the connector is properly installed, the cable should be positioned and secured to minimize stress on the cable and connector. UGD-D01196 Airspan Commercial and Internal Use...
Check Power Supply for proper polarization. Note: Airspan supplies two (2) types of cable, either black wire and white wire cable or black wire and blue wire cable. The cables’ specs are identical only the colors are different. Figure 25: DC Power Connection...
Position the pins correctly, the connector is secured to the unit with a locking ring that is screwed into place. Use firm hand pressure only, the connector has a built in sealing ring. Figure 27: attaching power cable to AirHarmony UGD-D01196 Airspan Commercial and Internal Use...
The third-party external AC/DC Power Converter is an optional unit that connects to the AirHarmony-4200 DC in the event there is no -48VDC availability at the site. Note: Airspan recommends using the AC/DC Power Converter for the AirHarmony-4200 DC. Available from Airspan if required. Figure 28: Optional AC/DC Converter...
Small flat blade screw driver (insulated shaft recommended) Medium Philips head screw driver 13 mm wrench Required Ancillary Equipment Laptop PC for initial configuration Cable for temporary connection of the laptop Other installed materials Cable ties Labels (good to have) UGD-D01196 Airspan Commercial and Internal Use...
Resource Block locations in the presence of an interfering signal IPSec Internet Protocol Security is a protocol suite for securing Internet Protocol (IP) communications by authenticating and encrypting each IP packet of a communication session Light Emitting Diode Long Term Evolution UGD-D01196 Airspan Commercial and Internal Use...
Page 52
TCP Software Defined Radio Time-Division Duplexing. A transceiver mode where the transmitter and receiver operate on the same carrier frequency User Equipment. The end user in LTE WEEE Waste Electrical and Electronic Equipment UGD-D01196 Airspan Commercial and Internal Use...