DATA
Zone Types 21-30 are applicable to the NX8-E control panel ONLY
GAS DETECTION- Creates an instant alarm regardless of the armed state of the control panel. It will
21
display on the keypad and activate the keypad sounder.
LOW TEMP DETECTION- Creates an instant silent alarm regardless of the armed state of the control
22
panel. It will display on the keypad and activate the keypad sounder.
HIGH TEMP DETECTION- Creates an instant silent alarm regardless of the armed state of the control
23
panel. It will display on the keypad and activate the keypad sounder.
MANUAL FIRE - This zone will illuminate the Fire LED and sound the temporal siren each time the zone is
24
shorted. It will also rapidly flash the Fire LED indicating a trouble if the zone is open.
CHIME ONLY - Creates no alarm regardless of the armed state of the control panel. It will chime anytime it
25
is faulted and will display on the keypad. Local only.
INTERIOR FOLLOWER DELAY 2 - This zone will be instant when the system is armed and no entry or exit
26
delay is being timed. It is delayed during entry and exit delay 2 times. This zone will automatically bypass if
enabled in Segment 1 of Location 23.
INTERIOR FOLLOWER FORCE ARMABLE - This zone will be instant when the system is armed and no
27
entry or exit delay is being timed. It is delayed during entry and exit delay 1 times. This zone will
automatically bypass if enabled in Segment 1 of Location 23.
ENTRY/EXIT FORCE ARMABLE DELAY 2 - A trip will start entry delay 2. The lack of a trip during exit
28
delay will enable the Automatic Bypass or Instant mode if so programmed.
INTERIOR FOLLOWER WITH ACTIVITY SUPERVISION ENABLED - This zone will be instant when the
system is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. It
29
will send a report if the zone activity time is reached without a change of state. Refer to Location 40 /
Segment 11. This zone will automatically bypass if enabled in Segment 1 of Location 23.
ENTRY/EXIT WITH ACTIVITY SUPERVISION ENABLED- A trip will start entry delay 1. It will send a report
30
if the zone activity time is reached without a change of state. Refer to Location 40 / Segment 11. The lack
of a trip during exit delay will enable the Automatic Bypass or Instant mode if so programmed.
PROGRAMMING THE ZONE CONFIGURATION AND PARTITION FOR EACH ZONE
The programming for all zone information is performed in the NX8/NX8-E control panel. For instructions on
accessing and programming the NX8/NX8-E, as well as changing the characteristics of a configuration group,
refer to the NX8/NX8-E Installation Manual. The following programming information is taken from the NX8/NX8-E
Installation Manual.
LOCATION 25 CONFIGURATION GROUP ZONES 1-8 (8 segments, numerical data)
Location 25 contains the Configuration Group (Zone type) for zones 1-9. Segment 1 is for zone 1; Segment 8 is
for zone 8. Default configurations are found in the table on page 4.
LOCATION 26 PARTITION SELECT ZONES 1-8 (8 segments, feature selection data)
Location 26 is used to select the partition(s) that zones 1-8 reside in. A zone may reside in any combination of
the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions
are armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Location
28 has 8 segments. Segment 1 corresponds to zone 1 and Segment 8 corresponds to zone 8.
Segments 1 - 8:
DESCRIPTION OF DEFAULT CONFIGURATION
1 = Partition #1
2 = Partition #2
3 = Partition #3
4 = Partition #4
5 = Partition #5
6 = Partition #6
7 = Partition #7
8 = Partition #8
NX216-E ZONE EXPANDER
5