Default Zone Configurations - CADDX NX216-E Installation Manual

Zone expander
Table of Contents

Advertisement

Zones can be programmed to be one of thirty different zone configurations (zone types). Configurations # 17
through 20 can be used for wireless or hardwired zones using European double EOL configuration. The default
zone configurations are listed below. These zone configurations can be customized by programming locations
110 to 169. NOTE #1: Zone Types 21-30 are applicable to the NX8-E control panel ONLY. NOTE #2: The
expander zones will not follow the Fast Loop Response.
DATA
"1"
DAY ZONE - Instant when system is armed trouble zone when system is disarmed.
"2"
24-HOUR AUDIBLE - Creates an instant yelping siren alarm regardless of the armed state of the panel.
ENTRY/EXIT DELAY 1 - A trip will start entry delay 1. The lack of a trip during exit delay will enable the
"3"
Automatic Bypass or Instant mode if so programmed.
FOLLOWER WITH AUTO-BYPASS DISABLED - This zone will be instant when the system is armed and
"4"
no entry or exit delays are being timed. It is delayed during entry and exit delay times. This zone will not
bypass in Stay Mode, nor automatically bypass even if enabled in Segment 1 / Location 23.
INTERIOR FOLLOWER WITH AUTO- BYPASS ENABLED - This zone will be instant when the system is
"5"
armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. This zone
will bypass in Stay Mode, and automatically bypass if enabled in Segment 1 of Location 23.
"6"
INSTANT - This zone creates an instant alarm whenever it is tripped and the Armed LED is on.
24-HOUR SILENT - Creates an instant silent alarm regardless of the armed state of the control panel. It will
"7"
not display on the keypad.
FIRE - This zone will illuminate the Fire LED and sound the temporal siren each time the zone is shorted. It
"8"
will also rapidly flash the Fire LED indicating a trouble if the zone is open.
ENTRY/EXIT DELAY 2 - A trip will start entry delay 2. The lack of a trip during exit delay will enable the
"9"
Automatic Bypass or Instant mode if so programmed.
24-HOUR SILENT SUPERVISED - Creates an instant silent alarm regardless of the armed state of the
"10"
control panel. It will display on the keypad.
KEYSWITCH ZONE - This zone type will arm and disarm the partition or partitions of the control panel that
"11"
resides in each time the zone is shorted. Keyswitch arming will report as user #99.
INTERIOR FOLLOWER WITH "CROSS ZONE" ENABLED - This zone will be Instant when the system is
armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. If a "Cross
"12"
Zone" is not being timed it will start a "Cross Zone" timer. If a "Cross Zone" is being timed it will create an
Instant alarm. This zone will bypass in Stay Mode and automatically bypass when enabled in Segment 1 of
Location 23.
INSTANT ENTRY GUARD - This zone creates an instant alarm whenever it is tripped and the Stay LED is
"13"
off. It will start an entry delay time 2 if it is tripped and the system is armed and the Stay LED is on.
ENTRY/EXIT DELAY 1 WITH GROUP BYPASS ENABLED - A trip will start entry delay 1. This zone will
"14"
bypass when the "Group Bypass" command is entered at the keypad. The lack of a trip during exit delay
will enable the Automatic Bypass or Instant mode if so programmed.
INTERIOR FOLLOWER WITH GROUP BYPASS ENABLED - This zone will be instant when the system is
armed and no entry or exit delays are being timed. It is delayed during entry/exit delay times. This zone will
"15
bypass when the "Group Bypass" command is entered at the keypad. This zone will bypass in Stay Mode
and automatically bypass even if enabled in Segment 1 / Location 23.
INSTANT WITH GROUP BYPASS ENABLED - This zone creates an instant alarm whenever it is tripped
"16"
and the Armed LED is on. This zone will bypass when the "Group Bypass" command is entered at the
keypad.
ENTRY/EXIT DELAY 1 WITH TAMPER ENABLED - A trip will start entry delay 1. The lack of a trip during
"17"
exit delay will enable the Automatic Bypass or Instant mode if so programmed. This configuration group
can be used to enable tamper on a wireless transmitter.
INTERIOR FOLLOWER WITH TAMPER AND AUTO-BYPASS ENABLED - This zone will be instant when
the system is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay
"18"
times. This zone will bypass in Stay Mode and automatically bypass if enabled in Segment 1 / Location 23.
This configuration group can be used to enable tamper on a wireless transmitter.
INSTANT WITH TAMPER ENABLED - This zone creates an instant alarm whenever it is tripped and the
"19"
Armed LED is on. This configuration group can be used to enable tamper on a wireless transmitter.
ENTRY/EXIT DELAY 2 WITH TAMPER ENABLED - A trip will start entry delay 2. The lack of a trip during
"20"
exit delay will enable the Automatic Bypass or Instant mode if so programmed. This configuration group
can be used to enable tamper on a wireless transmitter.

DEFAULT ZONE CONFIGURATIONS

DESCRIPTION OF DEFAULT CONFIGURATION
NX216-E ZONE EXPANDER
4

Advertisement

Table of Contents
loading

Table of Contents