*1 Details of P1.12 (NORMAL STANDBY CAUSE)
When TV set is powered off due to normal use or product specification, the last cause will be recorded.
The code, character string and description for the standby cause are below.
If you power off by remote, the cause will not be recorded.
Code
Character string
2
NO_OPERT
3
NO_SIGNA
6
SLEEP_TM
8
OFF_232C
*2 Details of P1.13 (ERROR STANDBY CAUSE)
When TV set is powered off due to any anomaly detection, the past 5 causes will be recorded.
You can confirm the time those causes occurred and character string in the adjustment process mode menu. (Page 28/29)
The time is accumulated total after TV set is powered on, and the value corresponds to "Center Acutime" in the adjustment process mode menu.
The code, character string and description for the standby cause are below.
If no error has occurred, the code is 0 and the character string is "NO RECORD".
Code
Character string
1A
E_MONITR
1C
E_CVICBT
22
E_TCNERR
48
E_MRESET
50
E_TCNF_S
54
E_TCON_E
Monitor ERR STBY table
Outline: Communication/Power failure detected by the monitor microprocessor is stored in EEPROM, and last 4 abnormal
can be confirmed in the Process mode A.
Location: Page 1 of the process mode A: MONITOR ERR CAUSE. "0" if there is no error. It is cleared to 0 on the last page of
the process mode A.
Display
02
Initial communication from the main CPU is not received.
03
Only the initial communication is received.
04
Until panel information request reception
05
Until initialization completion reception
06
Until version notification transmission
07
Until start-up information notification transmission
08
Until start-up information response reception
09
Until time-out setting reception
0A
Request time-out
0B
Restart time-out during the beginning of time acquisition start-up
0C
Ending sequence time-out
0D
Preset start-up time-out during completion
0E
Download, start-up time-out
0F
Time acquisition time-out
11
Regular communication time-out
16
Backlight error
1A
Monitor temperature failure
1E
DET_13V failure
1F
DET_D3V3 failure
21
DET_PNLxxV failure
23
Error standby request from the main CPU
Description
No operation off
No signal off
Off timer
Command from RS232C
Description
Monitor trouble detected
Driver boot error
Software abnormality of LCD controller
Failure of resetting menu settings (Initial Setup - Reset)
T-CON FPGA status error
T-CON hung-up

Error description

5 – 10
Check UART bus between main CPU and sub CPU.
See p.6-5
- Check TV setting environment
- Check the other monitor (ref No.)
Check 13V power line.
Check D3V3 power line.
Check T-CON power line
Check ERROR STANDBY CAUSE (p.5-8)