Led Flashing Specification At The Time Of The Error - Sharp LC-46DH66E Service Manual

Hide thumbs Also See for LC-46DH66E:
Table of Contents

Advertisement

LC-46DH65E/S, LC-46DH66E

[2] LED flashing specification at the time of the error

Display method
Refer to Table 1.
Make the OPC LED flash using the [MENU] key on the remote control since the display for service persons is identified by the number of flashings
(once to 5 times).
Even if the [MENU] key is pressed again, it does not return to the display for customers (only the power LED flashes).
After recovering from an error, if the same error cannot be generated again, refer to MONITOR ERR CAUSE on the adjustment process screen.
LED flashing method
Synchronize the phases of the power LED and OPC LED.
If the LEDs have different number of flashings, adjust the flashing cycle to that where the LED flashes more times.
Power
Power
OPC
(Displayed by the
specific operation)
Table 1. Concrete flashing pattern
Item
Inverter/Lamp system failure
Power PWB failure (Power
failure, etc.)
Main PWB failure
(Communication failure, etc.)
Others
VerUP executing
VerUP succeeded
VerUP failed
System
ROM data failure
* 1: For details, refer to ERROR STANDBY CAUSE on the adjustment process screen.
* 2: If the boot section is abnormal, there is no flashing (flashing disabled).
All manuals and user guides at all-guides.com
<Flashing example for customers>
1500ms
300ms
300ms
<Flashing example for service persons>
300ms
300ms
For customers
Power
OPC
Red flashes once
Off
Red flashes twice
Off
Green flashes once
Off
Green flashes twice
Off
Orange flashes once
Off
Power green/OPC flash alternately
Green/Red flash
Off
alternately
Red flashes 3 times
Off
Green/Red flash
Off
alternately
1500ms
For service persons
Power
Red flashes once
Flashes once
Red flashes twice
Flashes once
Flashes twice
Flashes 3 times
Flashes 5 times
Green flashes once
Flashes once
Flashes twice
Flashes 3 times
Flashes 5 times
Green flashes twice
Flashes once
Flashes twice
Flashes 3 times
Orange flashes once
Off
Power green/OPC flash alternately
Green/Red flash
Off
alternately
Red flashes 3 times
Off
Green/Red flash
Off
alternately
4 – 14
Cause
OPC
Lamp error
AC_DET error
UR+13.5V error
D3.3V error
Panel power supply error
Initial communication error
Start-up confirmation commu-
nication error
Regular communication error
Other communication error
Temperature error
Sync error
Notification from the main
microprocessor (*1)
Version upgrading
Version upgrade succeeded
Version upgrade failed
Mounting discrimination con-
nector unplugged
Start-up after failing version
upgrade (*2)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc-46dh65esLc-46dh65e

Table of Contents