M-system M8SED1 Instruction Manual

Dc alarm

Advertisement

Quick Links

INSTRUCTION MANUAL
(thumbwheel switch adjustment, CE)

BEFORE USE ....

Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.

■ PACKAGE INCLUDES:

Signal conditioner ...............................................................(1)

■ MODEL NO.

Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.

POINTS OF CAUTION

■ CONFORMITY WITH EU DIRECTIVES

• Functional insulation is maintained between the input
and output.
• The equipment must be mounted inside a panel.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
• Install lightning surge protectors for those wires connect-
ed to remote locations.
■ POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 60mA

■ GENERAL PRECAUTIONS

• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.

■ ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within 0 to 55°C (32
to 131°F) with relative humidity within 30 to 95% RH in
order to ensure adequate life span and operation.
• Be sure that the ventilation slits are not covered with ca-
bles, etc.
DC ALARM
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
MODEL

■ WIRING

• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Output 1 Monitor LED
Body
Specifications
Output 2 Monitor LED

INSTALLATION

Use Installation Base (model: M8BSx).
M8SED1
Output 1
Setpoint Adj.
Mounting Screw
Output 2
4
4
Setpoint Adj.
3
1
EM-5380 P. 1 / 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the M8SED1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for M-system M8SED1

  • Page 1 • Do not install cables close to noise sources (relay drive cable, high frequency line, etc.). Thank you for choosing M-System. Before use, please check • Do not bind these cables together with those in which contents of the package you received as outlined below.
  • Page 2 4) Check that the output load is 60V DC/15W at the maxi- setpoint and check that the relay trips at the setpoint. mum. For maximum relay life with inductive loads, ex- When the trip points are shifted, please contact M-System’s ternal protection is recommended. Sales Office or representatives.