Advertisement

INTRODUCTION

Congratulations on purchasing the MFJ-853H RF-Current Meter. The MFJ-
853H is designed for measuring RF current distribution on antenna elements
and radials, ground wires, and coax shields. Here are some important features
we think you'll like:
Range: Measures RF current in three ranges: 3A, 10A, and 30A.
Low Interaction: Sense coil has minimal effect on circuits under test.
Large Cable Capacity: Accepts cables up to approximately 1/2" in diameter.
Power: No power source needed.
Non-metallic case: Minimizes field disturbance for accurate reading.
Handheld Size: Light weight, only 2.25" x 1" x 3.75"

CONTROLS

1. Sense Coil: Clamps onto conductor under test, accepts diameters to around
1/2" .
2. Meter: Calibrated scale indicates readings in Amps.
3. Range: Selects from three measurement ranges.

OPERATING INSTRUCTIONS

Using the Sense Coil: The sense coil snaps over wires and cables, as shown
below. To unlatch, squeeze the nylon carrier between thumb and forefinger--
applying opposing pressure.
The coil's top section should move forward
slightly. With pressure applied, lift up to open. Position the wire or cable inside
the core opening. Close the lid over the cable, pressing down until latch clicks
shut.
Press
Unlatch
Lift
Click!
1
2
3
Meter: The meter is scaled from 0 to 100. On the 10A range, move the
decimal point 1 place to the left (100 = 10 A). To convert meter readings made
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MFJ-853H and is the answer not in the manual?

Questions and answers

Summary of Contents for MFJ Enterprises MFJ-853H

  • Page 1 INTRODUCTION Congratulations on purchasing the MFJ-853H RF-Current Meter. The MFJ- 853H is designed for measuring RF current distribution on antenna elements and radials, ground wires, and coax shields. Here are some important features we think you'll like: Range: Measures RF current in three ranges: 3A, 10A, and 30A.
  • Page 2 on the 3A and 30A ranges, multiply accordingly. For example, a reading of 85 on the 30A range equals 30 x .85, or 25.5 A. The chart below will help you estimate readings quickly: Range Meter Reading Actual Value (Amps) 10.0 Range: The Range switch selects between three calibrated scales (from 3 to 30 Amps).
  • Page 3 2. MFJ Enterprises, Inc. agrees to repair or replace at MFJ's option without charge to the original owner any defective product under warrantee provided the product is returned postage prepaid to MFJ Enterprises, Inc.

Table of Contents