Wiring Diagram - Mitsubishi Electric Mr.Slim PUZ-A18NHA4R1 Service Manual

Table of Contents

Advertisement

8

WIRING DIAGRAM

PUZ-A18NHA4
PUZ-A18NHA4-BS
PUZ-A18NHA4R1 PUZ-A18NHA4R1-BS PUY-A12/18NHA4R1
[LEGEND]
SYMBOL
NAME
TB1
Terminal Block<Power Supply, Indoor/Outdoor>
MC
Motor for Compressor
MF1
Fan Motor
21S4
Solenoid Valve (Four-Way Valve)
63H
High Pressure Switch
TH3
Thermistor<Outdoor Pipe>
TH6
Thermistor<Outdoor 2-Phase Pipe>
TH7
Thermistor<Outdoor>
TH8
Thermistor<Heatsink>
TH32
Thermistor<Shell>
LEV-A
Electronic Expansion Valve
ACL
Reactor
CY1,CY2
Capacitor
P.B.
Power Circuit Board
TABR/S
Connection Terminal<L1/L2-Phase>
TABU/V/W
Connection Terminal<U/V/W-Phase>
TH32
TH7 TH6 TH3
C. B.
CNF1
MF1
1
(WHT)
7
1 2
1
MS
TH32
TH7/6
3~
(BLK)
(RED)
3
TRANS
1
CNDC
(PNK)
F2
CNAC
CNS
(WHT)
(WHT)
1
2
F1
3
1
3
4
W
P. B.
PFC
TABR
RED
WHT
TABS
CB1
CB2
1 MODEL SELECT
The black square (
) indicates a switch position.
MODEL
SW6
ON
PUZ-A18NHA4
OFF
1 2 3 4 5 6
7 8
ON
PUY-A12NHA4
OFF
1 2 3 4 5 6
7 8
ON
PUY-A18NHA4
OFF
1 2 3 4 5 6
7 8
2. SW5-1 to 4 : Function switch
OCH481C
SYMBOL
PFC
Converter
IPM
Power Module
CB1~CB3
Main Smoothing Capacitor
N.F.
Noise Filter Circuit Board
Connection Terminal<L1-Phase>
LI/LO
NI/NO
Connection Terminal<L2-Phase>
EI,E2,E3
Connection Terminal<Ground>
52C
52C Relay
C.B.
Controller Circuit Board
SW1
Switch<Forced Defrost, Defect History
Record Reset, Refrigerant Address>
SW4
Switch<Test Operation>
SW5
Switch<Function Switch>
SW6
Switch<Model Select>
SW7
Switch<Function Setup>
SW8
Switch<Function Setup>
LEV-A
63H
M
3
4
1
2
1
6
1
3
TH3
LEV-A
CNVMNT
(WHT)
(WHT)
(WHT)
1
CNM
1
3
(WHT)
63H
(YLW)
CN2
CN4
(WHT)
(WHT)
1
7
1 2
2
5
F3
3
1
3
1
21S4
F4
(GRN)
21S4
PUZ only
RED
RED
WHT
WHT
ACL
MC
MS
3~
U
V
2
CN5
1
(RED)
2
IPM
2
CN4
1
(WHT)
2
TABU
CN3
1
TABV
(WHT)
2
TABW
TH8
5
1
CN2
(WHT)
CB3
7
SW5-5.6
2
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
L1
L2 GR S1 S2 S3
POWER SUPPLY
Use copper supply wires.
208 / 230V 60Hz
PUY-A12/18NHA4
NAME
SYMBOL
SW9
LED1,LED2 LED<Operation Inspection Indicators>
F1~F4
SWP
CN31
SS
CNM
CNMNT
CNVMNT
CNDM
CN51
X51, X52, X55 Relay
When M-NET adapter is connected
5
5
1
1
1
5
CNMNT
(WHT)
1
14
CN31
CN52C
(RED)
3
1
2
A B S
1
TB7
2
5
M-NET
1
3
1
SV2
SS
(BLU)
(WHT)
RED
WHT
N. F.
LO
NO
1
2
1
3
1
2
1
3
U
U
LI
EI
NI
CY1
CY2
TB1
INDOOR
UNIT
16
PUY-A12/18NHA4-BS
PUY-A12/18NHA4R1-BS
NAME
Switch
Fuse<T6.3AL250V>
Switch<Pump Down>
Connector<Emergency Operation>
Connector<Connection for Option>
Connector<A-Control Service Inspection Kit>
Connector
<Connected to Optional M-NET Adapter Board>
Connector
<Connected to Optional M-NET Adapter Board>
Connector <Connected for Option (Contact Input)>
Connector <Connected for Option (Signal output)>
5
SW11
SW1
1
LED2
SW12
LED3
LED4
M-NET ADAPTER
2
CND
(WHT)
3
1
3
M-NET ADAPTER
SYMBOL
TB7
Terminal Block<M-net connection>
2
CN5
Connector<Transmission>
CND
Connector<Power Supply>
CN2M
Connector<M-NET communication>
SW1
Switch<Status of communication>
SW11
Switch<Address setting : 1s digit>
SW12
Switch<Address setting : 10s digit>
LED1
LED<Power Supply : DC5V>
LED2
LED<Connection to Outdoor Unit>
LED3
LED<Transmission : Sending>
LED4
LED<Transmission : Receiving>
LED5
LED<Power Supply : DC12V>
2
NAME