Download Print this page

Eeprom Copy Jig - Panasonic CT-32HC14J Service Manual

Advertisement

9 EEPROM copy jig

TOP PREVIOUS NEXT
This CTV has a feature that allows to clone or back-up main EEPROM data adjustments from a
CTV to other by connecting a jig to the CTV set. A jig part number TXFJIG01SER, is available
through Matsushita/Panasonic Services.
Preparation:
To connect this jig, remove the lower back cover as instructed on disassembly for service section on
this service manual and insert the jig into A15 connector located on the A-Board. (See figure)
Procedure to copy data:
1. Enter to service mode and display service menu.
2. Select "AREA" DAC and then press ACTION button on remote to enter. Press VOL right/left
to select one of the following options then press ACTION:
Select ALL to copy all main EEPROM data
¡
Select ADJ to copy only adjustment data.
¡
Select FIX to copy only fix data
¡
3. To copy data from main EEPROM to jig, select "IN→EX" DAC and press ACTION button on
remote.
4. To copy data from jig to main EEPROM, select "EX→IN" DAC and press ACTION button on
remote.
TOP PREVIOUS NEXT