Technical Data

Model No.:
Gas Type
Test Point Pressure
Main Burner (injector size)
Back Burner (Injector size)
Total Nominal Gas Consumption (MJ/h)
Main Burner Nominal Gas Consumption (MJ/h)
Back Burner Nominal Gas Consumption (MJ/h)
AC Adaptor Input:
Output:
Cord:
Model No.:
Gas Type
Test Point Pressure
Main Burner (injector size)
Back Burner (Injector size)
Total Nominal Gas Consumption (MJ/h)
Main Burner Nominal Gas Consumption (MJ/h)
Back Burner Nominal Gas Consumption (MJ/h)
AC Adaptor Input:
Output:
Cord:
Note:
► For outdoors use only
► Conversion to natural gas only to be done by authorized person
► The maximum cylinder size for use with this appliance is 9kgs
► The thread type of this appliance is G1/4B-19.
► Always keep the electrical components in dry condition
230-240VAC, 50Hz
12VAC 2000mA
250V, 10A
230-240VAC, 50Hz
12VAC 5000mA
250V, 10A
INALTO.HOUSE
IBBQBI4B
Universal LP Gas & Natural Gas
Universal LP Gas
2.75KPA
0.98mm
0.98mm
64.5
13×4
12.5×1
IBBQBI6B
Universal LP Gas & Natural Gas
Universal LP Gas
2.75KPA
0.98mm
0.98mm
90.5
13×6
12.5×1
Natural Gas
1.0KPA
1.50mm
1.65mm
57
11×4
13×1
Natural Gas
1.0KPA
1.50mm
1.65mm
79
11×6
13×1