Electrical Work

1. The supply voltage must be the same as the rated voltage of the air
conditioner.
2. Prepare the power source for exclusive use with the air conditioner.
Stripping length of the connecting cable
Terminal block
Earth line
Cord clamp
Power supply cord
Round type
L
N
terminal
Power supply cord
Model
Power source
Maximum running current
Plug socket & fuse rating
Power cord
CAUTION
• Wrong wiring connection may cause some electrical parts burn out.
• Be sure to comply with local rule on running the wire from indoor unit
to outdoor unit (size of wire and wiring method, etc.).
• Every wire must be connected fi rmly.
• If incorrect or incomplete wiring is carried out, it will cause an ignition
or smoke.
• Prepare the power supply for exclusive use with the air conditioner.
• This product can be connected to the mains.
Connection to fi xed wiring: A switch which disconnects all poles and
has a contact separation of at least 3 mm must be incorporated in the
fi xed wiring.
NOTE
: Connecting cable
• Wire type : More than 1.5 mm² (H07RN-F or 60245 IEC66) or 1.3 mm²
(AWG-16)
Terminal screw
Screw
Cord clamp
Connecting cable
Round type
1
2
3
terminal
Earth line
Connecting cable
Cable tie
Power supply cord
Connecting cable
Protective bush
RAS-24BKS-HK
RAS-30BKS-HK
50Hz, 220 V Single phase
13A
21A
16A
27A
4 mm
2
(H07RN-F or 60245 IEC66)
or 3.5 mm
2
(AWG-12)

Refrigerant Piping

Knockout of Pipe Cover For 30k only
Knockout procedure
• The indoor/outdoor connecting pipes can be connected in rear direction.
Take off the knockout part of the pipe cover through which pipes.
• Detach the pipe cover and tap on the knockout section a few times with
the shank of a screwdriver. A knockout hole can easily be punched.
* Be sure to wear heavy work gloves while working.
Process of installation protective bush For 24k, 30k
• Install the supplied protective bush and guard material around the
passage hole to protect wires and pipes.
Be sure to attach the pipe covers after pipes have been connected.
Cut the slits under the pipe covers to facilitate the installation.
After connecting the pipes, be sure to mount the pipe cover.
The pipe cover is easily mounted by cutting off the slit at the lower part of
the pipe cover.
Supplied protective bush
8
Rear direction
Pipe cover
PLATE-TRANSPORTATION
• Should be take off and no
need to fix.
Supplied passage hole guard material
* Attach the guard material securely so
that it does not come loose.