    Table of Contents Chapter 1 System Information 1.1 About this manual 1.2 How to set up the parameter 1.3 How to set up the parameter - II Chapter 2 System Setup 2.1 Interface selection 2.1.1 Keyboard emulation parameters setting 2.1.2 RS-232 communication setting 2.2 Scanning mode selection 2.3 Beeper tone selection 2.4 String Options (Prefix &...
  • Page 3: Chapter 1 System Information

    Chapter 1 - System Information 1.1 About this manual This User's Guide provides detailed programming instructions. Barcode scanners are factory programmed for the most common communication setting. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide. 1.2 How to set up the parameter -I (1) Scan Start Configuration (2) Scan all necessary labels for parameters that meet your applications.
  • Page 4: How To Set Up The Parameter

    1.3 How to set up the parameter - II Most of time the scanner only requests one read of parameters when changing to new values. You will hear two beeps when you successfully set to the new values. But for some special parameters, multiple reads are needed to complete the configuration.
  • Page 5: Chapter 2 System Setup

    Chapter 2 - System setup 2.1 Interface selection The scanner is designed to switch easily from interfaces. Remember to reset the interface before changing to PS/2 or RS232 cable. No presetting is requested for USB interface. Scanning USB bar code after the cable is changed and activating the scanner by plugging the USB cable again.
  • Page 6: Keyboard Emulation Parameters Setting

    2.1.1 Keyboard emulation parameters setting Start configuration End configuration ITEM OPTION *IBM AT IBM XT IBM PS/2 30-80 Device Selection for keyboard IBM 5550 Interface PS/2 25,30 NEC 9801 Reserved 1 Reserved 2 - 6 -...
  • Page 7 Start configuration End configuration ITEM OPTION * USA ITALIAN SPANISH FRENCH Language for Keyboard Interface GERMAN JAPANESE Multi-Language Support Reserved 1 - 7 -...
  • Page 8 Start configuration End configuration ITEM OPTION * Disable Function Key Enable Emulate External Keyboard * Disable Enable * Disable ALT Mode Enable NOTE : Emulate External Keyboard Scan the barcode below if you do not have an external keyboard. After scanning the Emulate External Keyboard bar code, you must power cycle your computer.
  • Page 9 Start configuration End configuration ITEM OPTION * Disable Caps Lock Enable * Disable Num Lock Enable Inter Character Delay (Default:00) Ref: Appendix(00—64H) - 9 -...
  • Page 10 Start configuration End configuration ITEM OPTION None * CR Terminator CR + LF Block transmission delay (Default:00) Ref: Appendix(00—0AH) Keyboard Speed (Default 00: high clock rate) Ref: Appendix(00—08H) - 10 -...
  • Page 11 2.1.2 RS-232 communication setting Start configuration End configuration ITEM OPTION 1200bps 2400bps 4800bps Baud Rate * 9600bps 19200bps 38400bps 7 Bits Data Bits * 8 Bits - 11 -...
  • Page 12 Start configuration End configuration ITEM OPTION * 1 Stop Bits Stop Bits 2 Stop Bits * NONE Parity EVEN Mark Space - 12 -...
  • Page 13 Start configuration End configuration ITEM OPTION Inter-character delay (Default:00) Ref: Appendix(00—64H) Block transmission delay (Default:00) Ref: Appendix (00-0AH) Response delay (Default:00) Ref: Appendix (00-0AH) * None RTS/CTS HANSHAKING ACK/NAK Xon/Xoff - 13 -...
  • Page 14 Start configuration End configuration ITEM OPTION None * CR+LF Terminator For RS-232 STX/ETX - 14 -...
  • Page 15 Start configuration End configuration ITEM OPTION * None RTS/CTS Handshaking ACK/NAK Xon/Xoff - 15 -...
  • Page 16: Scanning Mode Selection

    2.2 Scanning mode selection Start configuration End configuration ITEM OPTION * Trigger On/Good Read Off Trigger On/Off Continuous/Trigger Off Continuous/Testing Reading Mode Continuous/Trigger on Continuous /Auto power on Flash Flash / Auto Power On - 16 -...
  • Page 17: Beeper Tone Selection

    2.3 Beeper tone selection Start configuration End configuration ITEM OPTION Beep Tone (Default:09H) Ref: Appendix (00-10H) Beep Sound Duration (Default:05H) Ref: Appendix (00-10H) * Enable Power On Beeper Disable * ON Beeper - 17 -...
  • Page 18: String Options (Prefix & Suffix)

    2.4 String Options (Prefix & Suffix) This section describes the alterations which can be made to the format of the transmitted data string. A prefix and suffix of maximum 10 direct input may be included in front and at the end of scanned barcode. Format {Prefix} {Code ID} {Bar Code} {Suffix} How to set up a prefix?
  • Page 19: Setup Insertion

    Setup Insertion This section describes how to setup the insertion of output. NOTE : Max. 10 charters can be inserted each time  Max. Insertion group is only two.  Insertion group (01) or (02) can be used in different kinds of ...
  • Page 20 Example: To insert character “A” before the third digit(3) Make the decoded data: 12A3456789 How to set up a character you want to insert Scan Start Configuration barcode Scan “G1 Insertion character” Scan “4” and “1” from FULL ASCII Table Scan Confirm configuration barcode Scan End configuration barcode How to set up position you wish to place the character...
  • Page 21 Start configuration End configuration Confirm configuration ITEM OPTION Preamble (Default:00) Ref: Appendix Postamble (Default:00) Ref: Appendix G1 Insertion character (Default:00) Ref: Appendix G2 Insertion character (Default:00) Ref: Appendix G1 Character Position to be inserted (Default:00) Ref: Appendix G2 Character Position to be inserted (Default:00) Ref: Appendix - 21 -...
  • Page 22 Start configuration End configuration ITEM OPTION *Disable Bar Code ID Enable * Read 1 Time Accuracy Read 2 Times Reading Bar equals high Bar equals low Code Type Code Type UPC-A Interleaved 25 UPC-E Industrial 25 EAN-13 Matrix 25 EAN-8 China Postal Code Code 39 MSI/Plessey...
  • Page 23: Chapter 3 Barcode Parameters Setting

    Chapter 3 - BarCode parameters setting How to set up a Code ID? (1) Scan Start configuration bar code (2) Go to the ASCII Table and scan label that represent the desired characters to be inserted. (3) Scan Confirm configuration bar code (4) Scan End configuration bar code.
  • Page 24 Start configuration End configuration ITEM OPTION * Disable UPC-A Expand to EAN-13 Enable Disable Check Digit Send * Enable * Disable Truncate Leading Zero Enable Truncate Leading (Default:00) Ref: Appendix (00-0DH) Truncate Ending (Default:00) Ref: Appendix (00-0DH) Insert group selection Ref: Appendix(00—02H)...
  • Page 25 Start configuration End configuration ITEM OPTION * NONE 2 digits Supplement digits 5 digits 2 or 5digits Auto-discriminate Supplement - 25 -...
  • Page 26: Upc-E

    3.2 UPC-E Start configuration End configuration ITEM OPTION Disable Read * Enable Code ID setting (Default : G) Ref: Appendix (20-7EH) - 26 -...
  • Page 27 Start configuration End configuration ITEM OPTION * Disable UPC-E Expand to UPC-A Enable Disable Check Digit Send * Enable Truncate Leading (Default:00) Ref: Appendix (00-08H) Truncate Ending (Default:00) Ref: Appendix (00-08H) Insert group selection (Default:00) Ref: Appendix (00-02H) - 27 -...
  • Page 28 Start configuration End configuration ITEM OPTION * Disable Truncate Leading Zero Enable * None 2 digits Supplement digits 5 digits 2 or 5 digits Auto-discriminate Supplement - 28 -...
  • Page 29: Ean-13

    3.3 EAN-13 Start configuration End configuration ITEM OPTION Disable Read * Enable Code ID setting (Default : H) Ref: Appendix (20-7EH) Disable Check Digit Send * Enable Truncate Leading (Default : 00 ) Ref: Appendix (00-0DH) Truncate Ending (Default : 00 ) Ref: Appendix (00-0DH) - 29 -...
  • Page 30 Start configuration End configuration ITEM OPTION * None 2 digits Supplement digits 5 digits 2 or 5 digits Auto-discriminate Supplement * Disable ISBN/ISSN Conversion Enable Insert group selection (Default : 00 ) Ref: Appendix (00-02H) - 30 -...
  • Page 31: Ean-8

    3.4 EAN-8 Start configuration End configuration ITEM OPTION Disable Read * Enable Code ID setting (Default : I) Ref: Appendix (20-7EH) Disable Check Digit Send * Enable Truncate Leading (Default : 00) Ref: Appendix (00-08H) - 31 -...
  • Page 32 Start configuration End configuration ITEM OPTION Truncate Ending (Default : 00) Ref: Appendix (00-08H) * None 2 digits Supplement digits 5 digits 2 or 5 digits Auto-discriminate Supplement Insert group selection (Default : 00) Ref: Appendix (00-02H) - 32 -...
  • Page 33: Code39

    3.5 Code39 Start configuration End configuration ITEM OPTION Disable Read * Enable Code ID setting (Default : J) Ref: Appendix (20-7EH) * Disable Check-sum verification Enable Disable Check-sum transmission * Enable - 33 -...
  • Page 34 Start configuration End configuration ITEM OPTION * Disable Append Enable Min. code length (Default: 00) Ref: Appendix (00-32H) Max. code length (Default: 32H) Ref: Appendix (00-32H) Format * Standard Code39 Code 39 Full ASCII - 34 -...
  • Page 35 Start configuration End configuration ITEM OPTION * Disable Transmit Start/End Character Enable Truncate Leading (Default: 00) Ref: Appendix (00-32H) Truncate Ending (Default: 00) Ref: Appendix (00-32H) Insert group selection (Default: 00) Ref: Appendix (00-02H) - 35 -...
  • Page 36: Codabar

    3.6 Codabar Start configuration End configuration ITEM OPTION Disable Read * Enable Code ID setting (Default : K) Ref: Appendix (20-7EH) - 36 -...
  • Page 37 Start configuration End configuration ITEM OPTION Disable Check-sum verification * Enable * Disable Check-sum transmission Enable * Disable Append Enable Truncate Leading (Default:00) Ref: Appendix (00-7EH) - 37 -...
  • Page 38 Start configuration End configuration ITEM OPTION Truncate Ending (Default:00) Ref: Appendix (00-7EH) * ABCD/ABCD Start/End type abcd/abcd abcd/tn*e * Disable Start/End transmission Enable Min. code length (Default: 05) Ref: Appendix (00-3CH) - 38 -...
  • Page 39 Start configuration End configuration ITEM OPTION Max. code length (Default: 3CH) Ref: Appendix (00-3CH) Insert group selection (Default: 00) Ref: Appendix (00-02H) - 39 -...
  • Page 40: Code93

    3.7 Code93 Start configuration End configuration ITEM OPTION Disable Read * Enable Code ID setting (Default : L) Ref: Appendix (20-7EH) Disable Check-sum verification * Enable - 40 -...
  • Page 41 Start configuration End configuration ITEM OPTION * Disable Check-sum transmission Enable Min. code length (Default: 00) Ref: Appendix (0-50H) Max. code length (Default: 50H) Ref: Appendix (0-50H) Truncate Leading (Default: 00) Ref: Appendix (00-7EH) Truncate Ending (Default: 00) Ref: Appendix (00-7EH) Insert group selection Ref: Appendix (00-02H) - 41 -...
  • Page 42: Code128

    3.8 Code 128 Start configuration End configuration ITEM OPTION Disable Read * Enable Code ID setting (Default : M) Ref: Appendix (20-7EH) Disable Check-sum verification * Enable - 42 -...
  • Page 43 Start configuration End configuration ITEM OPTION * Disable Check-sum transmission Enable * Disable FNC2 Append Enable * Disable UCC/EAN128 Enable * Disable FNC1 transmission Enable - 43 -...
  • Page 44 Start configuration End configuration ITEM OPTION Truncate Leading (Default: 00) Ref: Appendix (00-7FH) Truncate Ending (Default: 00) Ref: Appendix (00-7FH) Min. code length (Default: 00) Ref: Appendix (00-7FH) Max. code length (Default: 7FH) Ref: Appendix (00-7FH) Insert group selection (Default: 00) Ref: Appendix (00-02H) - 44 -...
  • Page 45: Interleaved2 Of

    3.9 Interleaved 2 of 5 Start configuration End configuration ITEM OPTION * Disable Read Enable Code ID setting (Default : N) Ref: Appendix (20-7EH) Disable Check-sum verification *Enable Disable Check-sum transmission * Enable - 45 -...
  • Page 46 Start configuration End configuration ITEM OPTION Truncate Leading (Default : 00) Ref: Appendix (00-7EH) Truncate Ending (Default : 00) Ref: Appendix (00-7EH) Min. code length (Default : 00) Ref: Appendix (00-7FH) Max. code length (Default : 7FH) Ref: Appendix (00-7FH) Insert group selection (Default : 00) Ref: Appendix (00-02H)
  • Page 47: Industrial 2Of

    3.10 Industrial 2 of 5 Start configuration End configuration ITEM OPTICON * Disable Read Enable Code ID setting (Default : O) Ref: Appendix (20-7EH) Min. code length (Default : 00) Ref: Appendix (00-32H) Max. code length (Default : 32H) Ref: Appendix (00-32H) - 47 -...
  • Page 48 Start configuration End configuration ITEM OPTION Truncate Leading (Default : 00) Ref: Appendix (00-32H) Truncate Ending (Default : 00) Ref: Appendix (00-32H) * Disable Check-sum verification Enable Disable Check-sum transmission * Enable Insert group selection (Default : 00) Ref: Appendix (00-02H) - 48 -...
  • Page 49: Matrix 2 Of

    3.11 Matrix 2 of 5 Start configuration End configuration ITEM OPTION * Disable Read Enable Code ID setting (Default : P) Ref: Appendix (20-7EH) * Disable Check-sum verification Enable - 49 -...
  • Page 50 Start configuration End configuration ITEM OPTION Disable Check-sum transmission * Enable Truncate Leading (Default : 00) Ref: Appendix (00-50H) Truncate Ending (Default : 00) Ref: Appendix (00-50H) Min. code length (Default : 0B) Ref: Appendix (00-50H) Max. code length (Default : 50H) Ref: Appendix (00-50H) Insert group selection (Default : 00)
  • Page 51 3.12 CHINA POSTAL CODE Start configuration End configuration ITEM OPTION * Disable Read Enable Code ID setting (Default : Q) Ref: Appendix (20-7EH) * Disable Check-sum verification Enable Disable Check-sum transmission * Enable - 51 -...
  • Page 52 Start configuration End configuration ITEM OPTION Truncate Leading (Default : 00) Ref: Appendix (00-50H) Truncate Ending (Default : 00) Ref: Appendix (00-50H) Min.code length (Default : 00) Ref: Appendix (00-50H) Max.code length (Default : 50H) Ref: Appendix (00-50H) Insert group selection (Default : 00) Ref: Appendix (00-02H) - 52 -...
  • Page 53: Msi/Plessey

    3.13 MSI/Plessey Start configuration End configuration ITEM OPTION * Disable Read Enable Code ID setting (Default : R) Ref: Appendix (20-7EH) * Disable MOD 10 Check-sum verification MOD 10/10 MOD 11/10 - 53 -...
  • Page 54 Start configuration End configuration ITEM OPTION Disable Check-sum transmission * Enable Truncate Leading (Default : 00) Ref: Appendix (00-3CH) Truncate Ending (Default : 00) Ref: Appendix (00-3CH) Min. code length (Default : 00) Ref: Appendix (00-3CH) Max. code length (Default : 3CH) Ref: Appendix (00-3CH) Insert group selection (Default : 00)
  • Page 55 3.14 CODE 32 (Italian Pharma-Code) Start configuration End configuration ITEM OPTION * Disable Read Enable Code ID Setting (Default:S) Ref: Appendix (20-7EH) Disable Check-sum verification * Enable Disable Check-sum transmission * Enable - 55 -...
  • Page 56 Start configuration End configuration ITEM OPTION Truncate Leading (Default : 00) Ref: Appendix (00-0AH) Truncate Ending (Default : 00) Ref: Appendix (00-0AH) Insert group selection (Default : 00) Ref: Appendix (00-02H) - 56 -...
  • Page 57: Code

    3.15 CODE 11 Start configuration End configuration ITEM OPTION * Disable Read Enable Code ID setting (Default:T) Ref: Appendix (20-7EH) Disable Check-sum verification * Enable - 57 -...
  • Page 58 Start configuration End configuration ITEM OPTION * Disable Check-sum transmission Enable Truncate Leading (Default : 00) Ref: Appendix (00-50H) Truncate Ending (Default : 00) Ref: Appendix (00-50H) Min. code length (Default : 00) Ref: Appendix (00-50H) Max. code length (Default : 50H) Ref: Appendix (00-50H) Insert group selection (Default : 00)
  • Page 59: Telepen

    3.16 Telepen Start configuration End configuration ITEM OPTION * Disable Read Enable Code ID setting (Default:V) Ref: Appendix (20-7EH) Disable Check-sum verification * Enable Only Numnic Data Format *Full ASCII - 59 -...
  • Page 60 Start configuration End configuration ITEM OPTION * Disable Check-sum transmission Enable Truncate Leading (Default : 00) Ref: Appendix (00-40H) Truncate Ending (Default : 00) Ref: Appendix (00-40H) Min. code length (Default : 00) Ref: Appendix (00-40H) Max. code length (Default : 40H) Ref: Appendix (00-40H) Insert group selection (Default : 00)
  • Page 61: Gs1 Data Bar

    3.17 GS1 Data Bar (RSS) Start configuration End configuration ITEM OPTION Enable RSS-14 *Disable Enable RSS-14 LIMITED *Disable Enable RSS-14 EXPANDED *Disable Enable RSS TO UPC/EAN *Disable - 61 -...
  • Page 62 3.18 Function Key Emulation Start configuration End configuration ITEM OPTION * Disable Function Key Enable Code 39 format Full ASCII Code 39 To scan a function key barcode label, Full ASCII Code 39 must be enabling. Please refer to Full ASCII Code 39 Table to produce the function key barcode label.
  • Page 63 PAGE UP($E) F5($U) PAGE DOWN($F) F6($V) BS($H) F7($W) TAB($I) F8($X) HOME($K) F9($Y) END($L) F10($Z) ENTER($M) ESC(%A) INSERT($N) F11(%B) DELETE($O) F12(%C) - 63 -...
  • Page 64 Appendix A – - 64 -...
  • Page 65 Char. Char. “ & ‘ < > - 65 -...
  • Page 66 Char. Char. ‘ - 66 -...
  • Page 67 Table-Hex HEXADCIMAL Confirm configuration End Configuration - 67 -...
  • Page 68 Function Key Table NULL DOWN LEFT RIGHT PAGE UP PAGE DOWN HOME ENTER INSERT DELETE - 68 -...
  • Page 69 DEFAULT CHECK VERSION Version: 3.1 - 69 -...