Table of Contents Chapter 1 System Information 1.1 About this manual 1.2 How to set up the parameter 1.3 How to set up the parameter - II Chapter 2 System Setup 2.1 Interface selection 2.1.1 Keyboard emulation parameters setting 2.1.2 RS-232 communication setting 2.2 Scanning mode selection 2.3 Beeper tone selection 2.4 String Options (Prefix &...
Chapter 1 - System Information 1.1 About this manual This User's Guide provides detailed programming instructions. Barcode scanners are factory programmed for the most common communication setting. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide. 1.2 How to set up the parameter -I (1) Scan Start Configuration (2) Scan all necessary labels for parameters that meet your applications.
1.3 How to set up the parameter - II Most of time the scanner only requests one read of parameters when changing to new values. You will hear two beeps when you successfully set to the new values. But for some special parameters, multiple reads are needed to complete the configuration.
Chapter 2 - System setup 2.1 Interface selection The scanner is designed to switch easily from interfaces. Remember to reset the interface before changing to PS/2 or RS232 cable. No presetting is requested for USB interface. Scanning USB bar code after the cable is changed and activating the scanner by plugging the USB cable again.
2.1.1 Keyboard emulation parameters setting Start configuration End configuration ITEM OPTION *IBM AT IBM XT IBM PS/2 30-80 Device Selection for keyboard IBM 5550 Interface PS/2 25,30 NEC 9801 Reserved 1 Reserved 2 - 6 -...
Page 7
Start configuration End configuration ITEM OPTION * USA ITALIAN SPANISH FRENCH Language for Keyboard Interface GERMAN JAPANESE Multi-Language Support Reserved 1 - 7 -...
Page 8
Start configuration End configuration ITEM OPTION * Disable Function Key Enable Emulate External Keyboard * Disable Enable * Disable ALT Mode Enable NOTE : Emulate External Keyboard Scan the barcode below if you do not have an external keyboard. After scanning the Emulate External Keyboard bar code, you must power cycle your computer.
Page 9
Start configuration End configuration ITEM OPTION * Disable Caps Lock Enable * Disable Num Lock Enable Inter Character Delay (Default:00) Ref: Appendix(00—64H) - 9 -...
2.2 Scanning mode selection Start configuration End configuration ITEM OPTION * Trigger On/Good Read Off Trigger On/Off Continuous/Trigger Off Continuous/Testing Reading Mode Continuous/Trigger on Continuous /Auto power on Flash Flash / Auto Power On - 16 -...
2.4 String Options (Prefix & Suffix) This section describes the alterations which can be made to the format of the transmitted data string. A prefix and suffix of maximum 10 direct input may be included in front and at the end of scanned barcode. Format {Prefix} {Code ID} {Bar Code} {Suffix} How to set up a prefix?
Setup Insertion This section describes how to setup the insertion of output. NOTE : Max. 10 charters can be inserted each time Max. Insertion group is only two. Insertion group (01) or (02) can be used in different kinds of ...
Page 20
Example: To insert character “A” before the third digit(3) Make the decoded data: 12A3456789 How to set up a character you want to insert Scan Start Configuration barcode Scan “G1 Insertion character” Scan “4” and “1” from FULL ASCII Table Scan Confirm configuration barcode Scan End configuration barcode How to set up position you wish to place the character...
Page 21
Start configuration End configuration Confirm configuration ITEM OPTION Preamble (Default:00) Ref: Appendix Postamble (Default:00) Ref: Appendix G1 Insertion character (Default:00) Ref: Appendix G2 Insertion character (Default:00) Ref: Appendix G1 Character Position to be inserted (Default:00) Ref: Appendix G2 Character Position to be inserted (Default:00) Ref: Appendix - 21 -...
Page 22
Start configuration End configuration ITEM OPTION *Disable Bar Code ID Enable * Read 1 Time Accuracy Read 2 Times Reading Bar equals high Bar equals low Code Type Code Type UPC-A Interleaved 25 UPC-E Industrial 25 EAN-13 Matrix 25 EAN-8 China Postal Code Code 39 MSI/Plessey...
Chapter 3 - BarCode parameters setting How to set up a Code ID? (1) Scan Start configuration bar code (2) Go to the ASCII Table and scan label that represent the desired characters to be inserted. (3) Scan Confirm configuration bar code (4) Scan End configuration bar code.
Page 24
Start configuration End configuration ITEM OPTION * Disable UPC-A Expand to EAN-13 Enable Disable Check Digit Send * Enable * Disable Truncate Leading Zero Enable Truncate Leading (Default:00) Ref: Appendix (00-0DH) Truncate Ending (Default:00) Ref: Appendix (00-0DH) Insert group selection Ref: Appendix(00—02H)...
3.17 GS1 Data Bar (RSS) Start configuration End configuration ITEM OPTION Enable RSS-14 *Disable Enable RSS-14 LIMITED *Disable Enable RSS-14 EXPANDED *Disable Enable RSS TO UPC/EAN *Disable - 61 -...
Page 62
3.18 Function Key Emulation Start configuration End configuration ITEM OPTION * Disable Function Key Enable Code 39 format Full ASCII Code 39 To scan a function key barcode label, Full ASCII Code 39 must be enabling. Please refer to Full ASCII Code 39 Table to produce the function key barcode label.
Need help?
Do you have a question about the BC-5000 and is the answer not in the manual?
Questions and answers