  • Page 1 BD-6500BT Bluetooth 2D Barcode Scanner Configuration Guide V 2.1...
  • Page 2: Table Of Contents

    Table of Contents 1 Getting Started ………………………………………………………………………………………………………. About This Guide ……………………………………………………………………………………….. Barcode Scanning ……………………………………………………………………………………….. Factory Defaults ………………………………………………………………………………………….. Pairing Cradle ……………………………………………………………………………………………… Pairing Smart Phone, Table PC …………………………………………………………………….. Multiple scanner pair one Cradle ………………………………………………………………… Sleeping time setting …………………………………………………………………………………… 2 Cradle Communication Interfaces ………………………………………………………………………….. USB interface ……………………………………………………………………………………………….
  • Page 3 5.2.2 EAN-8 …………………………………………………………………………………………………………… 21 5.2.3 EAN-13 ………………………………………………………………………………………………………… 5.2.4 UPC-E ………………………………………………………………………………………………………….. 5.2.5 UPC-A ………………………………………………………………………………………………………….. 5.2.6 Interleaved 2 of 5 …………………………………………………………………………………………. 30 5.2.7 Matrix 2 of 5 ………………………………………………………………………………………………… 31 5.2.8 Industrial 2 of 5 ……………………………………………………………………………………………. 32 5.2.9 Code 39 ……………………………………………………………………………………………………….. 33 5.2.10 CodaBar ………………………………………………………………………………………………………… 35 5.2.11 Code 93 …………………………………………………………………………………………………………...
  • Page 4: Getting Started

    BD-6500BT 2D BARCODER READER features fast scanning and decoding accuracy. Barcodes rotated at any angle can still be read with ease. When scanning a barcode, simply center the aiming beam or pattern projected by the BD-6500BT 2D BARCODER READER over the barcode. 1.3 Factory Def aults Scanning the following barcode can restore the engine to the factory defaults.
  • Page 5: Pairing Cradle

    1.4 Pairing Cradle Scan "Default" Scan "setting configuration" Scan "open SPP" Scan "disconnect previous pairing" Scan Cradle bottom code Scan "Repairing" Save BT SPP setting Scan "End BT SPP setting" Apple device needs enable transmission, others need to disable Enable iOS transmission Disable iOS transmission...
  • Page 6: Pairing Smart Phone, Table Pc

    1.5 Pairing Smart Phone , Table PC Scan "default" Scan "setting configuration: Open a HID connection Disconnect previous pairing BT visible setting Save BT HID configuration End BT HID configuration Apple device needs to enable transmission, others disable transmission Enable iOS transmission Disable iOS transmission Enable BT function in iPad or smart phone and then serach BT (NVC_MD_CS45) to pair.
  • Page 7: Multiple Scanner Pair One Cradle

    1.6 Multiple scanner pair one Cradle (2) Open SPP (1) Start (3) Disconnected previous connection (4) Scan receiver barcode (5) Reconnected (5) Save (6) End (7) BT receiving setting Remark: Please follow the step (1) ~ (6) for the first scanner. When it is connected (Blue Light), read the barcode as below.
  • Page 8: Sleeping Time Setting

    1.7 Sleeping time setting Save Sleeping mode Numeric Sleeping mode setting step: 1. Scan “default” 2. Scan “Sleeping Mode” 3. Setting sleeping mode numeric: (Unit: minute) For example: Set sleeping mode in 10 minutes. Then needs to scan numeric “0”, “1”, “0”. Remark: Sleeping time range is from 1 to 999 minutes, and each setting needs to have 3 digits.
  • Page 9: Cradle Communication Interfaces

    2. Cradle Communication Interf aces 2.1 USB Interface * USB-HID 2.2 USB COM Port Emulation If you connect the engine to the Host via a USB connection, the USB COM Port Emulation feature allows the Host to receive data in the way as a serial port does. A driver is required for this feature. USB COM Port Emulation...
  • Page 10: Usb Country Keyboard Types

    2.3 USB Country Keyboard Types Keyboard layouts vary from country to country. The default setting is 1-U.S. keyboard. *USA Belgium Brazil Canada Croatia Czech Denmark Finland France Germany Hungary Italy Latin Dutch Norway Poland Portugal Serbia...
  • Page 11 Slovakia Slovenia Spain Sweden Swiss-French Swiss-German Turkey-F Turkey-Q Japan...
  • Page 12: Convert Case

    2.4 Convert Case Scan the appropriate barcode below to convert barcode data to your desired case. * No Case conversion Convert All to Upper Case Convert All to Lower Case Example: W hen the Convert All to Lower Case feature is enabled, barcode data “AbC” is transmitted as “abc”.
  • Page 13: General Configuration

    3. General Configuration 3.1 Trigger Mode If the Trigger Mode is enabled, you could activate the scanner by providing an external hardware trigger, or using a serial trigger command. When in manual trigger mode, the scanner scans until a barcode is read, or until the hardware trigger is released.
  • Page 14: Video Reverse

    3.3 Video Reverse * Off 3.4 Beeper - Good Read * On 3.5 Beeper Tone - Good Read Middle * High...
  • Page 15: Beeper Duration - Good Read

    3.6 Beeper Duration - Good Read * Normal Short 3.7 Beeper Number - Good Read...
  • Page 16: Barcode Scanning Delay

    3.8 Barcode Scanning Delay * No Delay Delay 500ms Delay 2000ms...
  • Page 17: Data Formatting

    Data Formatting 4.1 General Configuration Add CR Add LF Add CR+LF Add TAB...
  • Page 18: Add Prefix

    4.2 Add Prefix Set Custom Prefix Save Not Save To set a customer prefix, scan the “Set Custom Prefix” barcode and the numeric barcodes which representing the hexadecimal values of a desired prefix, and then scan the “Save” barcode. Refer to Appendix 4: ASCII Table for hexadecimal values of characters.
  • Page 19: Add Suffix

    4.3 Add Suffix Set Custom Suffix Save Not Save To set a customer suffix, scan the “Set Custom Suffix” barcode and the numeric barcodes which representing the hexadecimal values of a desired suffix, and then scan the “Save” barcode. Refer to Appendix 4: ASCII Table for hexadecimal values of characters.
  • Page 20: Symbologies

    Symbologies 5.1 General Settings Enable All Symbologies...
  • Page 21: Symbologies

    5.2 1D Symbologies 5.2.1 Code 128 Restore Factory Defaults Restore the Factory Defaults of Code 128 Enable/Disable Code 128 * Enable Code 128 Disable Code 128 Message Length Message length can be set to the maximum value or minimum value. The value between the maximum and the minimum is valid.
  • Page 22: Ean-8

    5.2.2 EAN-8 Restore Factory Defaults Restore the Factory Defaults of EAN-8 Enable/Disable EAN-8 * Enable EAN-8 Disable EAN-8 Transmit Check Digit EAN-8 is 8 digits in length with the last one as its check digit used to verify the accuracy of the data. Transmit EAN-8 Check Digit * Do Not Transmit EAN-8 Check Digit Add-On Code...
  • Page 23 Enable 2-Digit Add-On Code Disable 2-Digit Add-On Code Enable 5-Digit Add-On Code Disable 5-Digit Add-On Code Add-On Code Required EAN-8 Add-On Code Required * EAN-8 Add-On Code Not Required ENA/JAN-8 Addenda Separator When this feature is enabled, there is a space between barcode and addenda. When this feature is disabled, there is no space.
  • Page 24: Ean-13

    5.2.3 EAN-13 Restore Factory Defaults Restore the Factory Defaults of EAN-13 Enable/Disable EAN-13 * Enable EAN-13 Disable EAN-13 Transmit Check Digit * Transmit EAN-13 Check Digit Do Not Transmit EAN-13 Check Digit Add-On Code Enable 2-Digit Add-On Code Disable 2-Digit Add-On Code Enable 5-Digit Add-On Code Disable 5-Digit Add-On Code...
  • Page 25 Add-On Code Required EAN-13 Add-On Code Required * EAN-13 Add-On Code Not Required ENA/JAN-13 Addenda Separator When this feature is enabled, there is a space between barcode and addenda. When this feature is disabled, there is no space. Enable ENA/JAN-13 Addenda Separator *Disable ENA/JAN-13 Addenda Separator ISBN Translate When enable this feature and is scanned, ENA13 Book land symbols are translated into their equivalent ISBN...
  • Page 26: Upc-E

    5.2.4 UPC-E Restore Factory Defaults Restore the Factory Defaults of UPC-E Enable/Disable UPC-E0/E1 Enable UPC-E0 Disable UPC-E0 Enable UPC-E1 Disable UPC-E1 UPCE0 Check Digit * Enable UPC-E0 Check Digit Disable UPC-E0 Check Digit...
  • Page 27 UPCE0 Expand UPCE0 expand expands the UPCE code to the 12 digits, UPC-A format. Enable UPC-E0 Expand * Disable UPC-E0 Expand UPCE0 Addenda Required When required is scanned, the scanner will only read UPC-E barcodes that have addenda. Enable UPC-E0 Required * Disable UPC-E0 Required UPCE0 Addenda Separator Enable UPC-E0 Separator...
  • Page 28 UPCE0 Addenda Enable 2 Digit Addenda Disable 2 Digit Addenda Enable 5 Digit Addenda Disable 5 Digit Addenda...
  • Page 29: Upc-A

    5.2.5 UPC-A Restore Factory Defaults Restore the Factory Defaults of UPC-A Enable/Disable UPC-A * Enable UPC-A Disable UPC-A UPC-A Check Digit * Enable UPC-A Check Digit Disable UPC-A Check Digit UPC-A Addenda Required When required is scanned, the scanner will only read UPC-E barcodes that have addenda. Enable UPC-A Required * Disable UPC-A Required...
  • Page 30 UPC-A Addenda Separator Enable UPC-A Separator * Disable UPC-A Separator UPC-A: Number System The number system digit of UPC symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will be not transmitted. * Enable UPC-A Number System Disable UPC-A Number System UPC-A: Addenda...
  • Page 31: Interleaved 2 Of 5

    5.2.6 Interleaved 2 of 5 Restore Factory Defaults Restore the Factory Defaults of Interleaved 2 of 5 Enable/Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 *Disable Interleaved 2 of 5 Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid.
  • Page 32: Matrix 2 Of 5

    5.2.7 Matrix 2 of 5 Restore Factory Defaults Restore the Factory Defaults of Matrix 2 of 5 Enable/Disable Matrix 2 of 5 Enable Matrix 2 of 5 * Disable Matrix 2 of 5 Message length can be set to the maximum value, minimum value. The value is valid between the maximum and the minimum.
  • Page 33: Industrial 2 Of 5

    5.2.8 Industrial 2 of 5 Restore Factory Defaults Restore the Factory Defaults of Industrial 2 of 5 Enable/Disable Industrial 2 of 5 Enable Industrial 2 of 5 *Disable Industrial 2 of 5 Message Length Message length can be set to the maximum value, minimum value. The value is valid between the maximum and the minimum.
  • Page 34: Code 39

    5.2.9 Code 39 Restore Factory Defaults Restore the Factory Defaults of Code 39 Enable/Disable Code 39 * Enable Code 39 Disable Code 39 Transmit Start/Stop Character Transmit Start/Stop Character *Do not Transmit Start/Stop Character Code 39 Check Character No Check Char *Validate and Transmit Validate no Transmit...
  • Page 35 Code 39 Full ASCII Enable Code 39 Full ASCII *Disable Code 39 Full ASCII Message Length Message length can be set to the maximum value, minimum value. The value is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail.
  • Page 36: Codabar

    5.2.10 Coda bar Restore Factory Defaults Restore the Factory Defaults of Coda bar Enable/Disable Codabar *Enable Coda bar Disable Coda bar Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid.
  • Page 37 Transmit Start/Stop Character Transmit Start/Stop Character *Do not Transmit Start/Stop Character Coda bar Check Character No Check Char Validate and Transmit *Validate no Transmit...
  • Page 38: Code 93

    5.2.11 Code 93 Restore Factory Defaults Restore the Factory Defaults of Code 93 Enable/Disable Code 93 *Enable Code 93 Disable Code 93 Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid.
  • Page 39: Gs1-128

    5.2.12 GS1-128 Restore Factory Defaults Restore the Factory Defaults of GS1-128 Enable/Disable GS1-128 *Enable GS1-128 Disable GS1-128 Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming command.
  • Page 40: Msi

    5.2.13 MSI Restore Factory Defaults Restore the Factory Defaults of MSI Enable/Disable MSI Enable MSI *Disable MSI Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command.
  • Page 41 MSI Check Character ValidateType10Transmit ValidateType10 ThenType11CharTransmit ValidateType10 ThenType11CharNoTransmit ValidateType10NoTransmit Validate2Type10NoTransmit Validate2Type10CharTransmit Validate2Type10CharNoTransmit *DisableMSICheck...
  • Page 42: Symbologies

    5.3 2D Symbologies 5.3.1 PDF 417 Restore Factory Defaults Restore the Factory Defaults of PDF 417 Enable/Disable PDF 417 *Enable PDF 417 Disable PDF 417 Enable/Disable Micro PDF 417 *Enable Micro PDF 417 Disable Micro PDF 417 Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum.
  • Page 43: Qr Code

    5.3.2 QR Code Restore Factory Defaults Restore the Factory Defaults of QR Code Enable/Disable QR Code *Enable QR Code Disable QR Code Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum is valid.
  • Page 44: Data Matrix

    5.3.3 Data Matrix Restore Factory Defaults Restore the Factory Defaults of Data Matrix Enable/Disable Data Matrix *Enable Data Matrix Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command.
  • Page 45: Maxi Code

    5.3.4 Maxi code Restore Factory Defaults Restore the Factory Defaults of Maxi code Enable/Disable Maxi code Enable Maxi code *Disable Maxi code Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum.
  • Page 46: Aztec

    5.3.5 Aztec Restore Factory Defaults Restore the Factory Defaults of Aztec Enable/Disable Aztec Enable Aztec *Disable Aztec Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command.
  • Page 47: Hanxin

    5.3.6 Hanxin Restore Factory Defaults Restore the Factory Defaults of Hanxin Enable/Disable Hanxin Enable Hanxin *Disable Hanxin Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command.
  • Page 48: Postal Symbologies

    Postal Symbologies 5.4.1 China Postal Code Restore Factory Defaults Restore the Factory Defaults of China Postal Code Enable/Disable China Postal Code Enable China Postal Code *Disable China Postal Code...
  • Page 49: Telepen

    5.4.2 Telepen Restore Factory Defaults Restore the Factory Defaults of Telepen Enable/Disable Telepen Enable China Telepen *Disable China Telepen...
  • Page 50: Appendix

    A p pendix 6.1 Appendix 1: ASCII Table Char (Null char.) (Start of Header) (Start of Text) (End of Text) (End of Transmission) (Enquiry) (Acknowledgment) (Bell) (Backspace) (Horizontal Tab) (Line Feed) (Vertical Tab) (Form Feed) (Carriage Return) (Shift Out) (Shift In) (Data Link Escape) (XON) (Device Control 1) (Device Control 2)
  • Page 51 Char (Space) (Exclamation Mark) " (Double Quote) (Number Sign) (Dollar Sign) (Percent) & (Ampersand) (Single Quote) (Right / Closing Parenthesis) (Right / Closing Parenthesis) (Asterisk) (Plus) (Comma) (Minus / Dash) (Dot) (Forward Slash) (Colon) (Semi-colon) < (Less Than) (Equal Sign) >...
  • Page 52 Char (AT Symbol) (Left / Opening Bracket) (Back Slash) (Right / Closing Bracket) (Caret / Circumflex) (Underscore)
  • Page 53 Char (Grave Accent) (Left/ Opening Brace) (Vertical Bar) (Right/Closing Brace) (Tilde) (Delete)
  • Page 54 ASCII Special Table Char Char Char L-Ctrl L-Shift L-Alt L-GUI R-Ctrl R-Shift R-Alt R-GUI Caps Lock Print Screen Scroll Lock Pause Insert Delete Home Page Up Page Down Left Arrow Right Arrow Up Arrow Down Arrow Num Lock(keypad) 1(keypad) 2(keypad) 3(keypad) 4(keypad) 5(keypad)
  • Page 55: Appendix 2: Digit Barcodes

    6.2 Appendix 2: Digit Barcodes...
  • Page 56: Appendix 3: Programming Command Guide

    6.3 Appendix 3: Programming Command Guide Programming Code Type Min Length Command Max Length Command Command Min: ^3020A02xx. Code 128 020A02 020A03 Max: ^3020A03xx. Min: ^3020403xx. Interleaved 2 of 5 020403 020404 Max: ^3020404xx. Min: ^3020802xx. Matrix 2 of 5 020802 020803 Max: ^3m20803xx.