Table of Contents 1 Getting Started ………………………………………………………………………………………………………. About This Guide ……………………………………………………………………………………….. Barcode Scanning ……………………………………………………………………………………….. Factory Defaults ………………………………………………………………………………………….. Pairing Cradle ……………………………………………………………………………………………… Pairing Smart Phone, Table PC …………………………………………………………………….. Multiple scanner pair one Cradle ………………………………………………………………… Sleeping time setting …………………………………………………………………………………… 2 Cradle Communication Interfaces ………………………………………………………………………….. USB interface ……………………………………………………………………………………………….
BD-6500BT 2D BARCODER READER features fast scanning and decoding accuracy. Barcodes rotated at any angle can still be read with ease. When scanning a barcode, simply center the aiming beam or pattern projected by the BD-6500BT 2D BARCODER READER over the barcode. 1.3 Factory Def aults Scanning the following barcode can restore the engine to the factory defaults.
1.5 Pairing Smart Phone , Table PC Scan "default" Scan "setting configuration: Open a HID connection Disconnect previous pairing BT visible setting Save BT HID configuration End BT HID configuration Apple device needs to enable transmission, others disable transmission Enable iOS transmission Disable iOS transmission Enable BT function in iPad or smart phone and then serach BT (NVC_MD_CS45) to pair.
1.6 Multiple scanner pair one Cradle (2) Open SPP (1) Start (3) Disconnected previous connection (4) Scan receiver barcode (5) Reconnected (5) Save (6) End (7) BT receiving setting Remark: Please follow the step (1) ~ (6) for the first scanner. When it is connected (Blue Light), read the barcode as below.
1.7 Sleeping time setting Save Sleeping mode Numeric Sleeping mode setting step: 1. Scan “default” 2. Scan “Sleeping Mode” 3. Setting sleeping mode numeric: (Unit: minute) For example: Set sleeping mode in 10 minutes. Then needs to scan numeric “0”, “1”, “0”. Remark: Sleeping time range is from 1 to 999 minutes, and each setting needs to have 3 digits.
2. Cradle Communication Interf aces 2.1 USB Interface * USB-HID 2.2 USB COM Port Emulation If you connect the engine to the Host via a USB connection, the USB COM Port Emulation feature allows the Host to receive data in the way as a serial port does. A driver is required for this feature. USB COM Port Emulation...
2.3 USB Country Keyboard Types Keyboard layouts vary from country to country. The default setting is 1-U.S. keyboard. *USA Belgium Brazil Canada Croatia Czech Denmark Finland France Germany Hungary Italy Latin Dutch Norway Poland Portugal Serbia...
2.4 Convert Case Scan the appropriate barcode below to convert barcode data to your desired case. * No Case conversion Convert All to Upper Case Convert All to Lower Case Example: W hen the Convert All to Lower Case feature is enabled, barcode data “AbC” is transmitted as “abc”.
3. General Configuration 3.1 Trigger Mode If the Trigger Mode is enabled, you could activate the scanner by providing an external hardware trigger, or using a serial trigger command. When in manual trigger mode, the scanner scans until a barcode is read, or until the hardware trigger is released.
4.2 Add Prefix Set Custom Prefix Save Not Save To set a customer prefix, scan the “Set Custom Prefix” barcode and the numeric barcodes which representing the hexadecimal values of a desired prefix, and then scan the “Save” barcode. Refer to Appendix 4: ASCII Table for hexadecimal values of characters.
4.3 Add Suffix Set Custom Suffix Save Not Save To set a customer suffix, scan the “Set Custom Suffix” barcode and the numeric barcodes which representing the hexadecimal values of a desired suffix, and then scan the “Save” barcode. Refer to Appendix 4: ASCII Table for hexadecimal values of characters.
5.2 1D Symbologies 5.2.1 Code 128 Restore Factory Defaults Restore the Factory Defaults of Code 128 Enable/Disable Code 128 * Enable Code 128 Disable Code 128 Message Length Message length can be set to the maximum value or minimum value. The value between the maximum and the minimum is valid.
5.2.2 EAN-8 Restore Factory Defaults Restore the Factory Defaults of EAN-8 Enable/Disable EAN-8 * Enable EAN-8 Disable EAN-8 Transmit Check Digit EAN-8 is 8 digits in length with the last one as its check digit used to verify the accuracy of the data. Transmit EAN-8 Check Digit * Do Not Transmit EAN-8 Check Digit Add-On Code...
Page 23
Enable 2-Digit Add-On Code Disable 2-Digit Add-On Code Enable 5-Digit Add-On Code Disable 5-Digit Add-On Code Add-On Code Required EAN-8 Add-On Code Required * EAN-8 Add-On Code Not Required ENA/JAN-8 Addenda Separator When this feature is enabled, there is a space between barcode and addenda. When this feature is disabled, there is no space.
Page 25
Add-On Code Required EAN-13 Add-On Code Required * EAN-13 Add-On Code Not Required ENA/JAN-13 Addenda Separator When this feature is enabled, there is a space between barcode and addenda. When this feature is disabled, there is no space. Enable ENA/JAN-13 Addenda Separator *Disable ENA/JAN-13 Addenda Separator ISBN Translate When enable this feature and is scanned, ENA13 Book land symbols are translated into their equivalent ISBN...
5.2.5 UPC-A Restore Factory Defaults Restore the Factory Defaults of UPC-A Enable/Disable UPC-A * Enable UPC-A Disable UPC-A UPC-A Check Digit * Enable UPC-A Check Digit Disable UPC-A Check Digit UPC-A Addenda Required When required is scanned, the scanner will only read UPC-E barcodes that have addenda. Enable UPC-A Required * Disable UPC-A Required...
Page 30
UPC-A Addenda Separator Enable UPC-A Separator * Disable UPC-A Separator UPC-A: Number System The number system digit of UPC symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will be not transmitted. * Enable UPC-A Number System Disable UPC-A Number System UPC-A: Addenda...
5.2.6 Interleaved 2 of 5 Restore Factory Defaults Restore the Factory Defaults of Interleaved 2 of 5 Enable/Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 *Disable Interleaved 2 of 5 Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid.
5.2.7 Matrix 2 of 5 Restore Factory Defaults Restore the Factory Defaults of Matrix 2 of 5 Enable/Disable Matrix 2 of 5 Enable Matrix 2 of 5 * Disable Matrix 2 of 5 Message length can be set to the maximum value, minimum value. The value is valid between the maximum and the minimum.
5.2.8 Industrial 2 of 5 Restore Factory Defaults Restore the Factory Defaults of Industrial 2 of 5 Enable/Disable Industrial 2 of 5 Enable Industrial 2 of 5 *Disable Industrial 2 of 5 Message Length Message length can be set to the maximum value, minimum value. The value is valid between the maximum and the minimum.
5.2.9 Code 39 Restore Factory Defaults Restore the Factory Defaults of Code 39 Enable/Disable Code 39 * Enable Code 39 Disable Code 39 Transmit Start/Stop Character Transmit Start/Stop Character *Do not Transmit Start/Stop Character Code 39 Check Character No Check Char *Validate and Transmit Validate no Transmit...
Page 35
Code 39 Full ASCII Enable Code 39 Full ASCII *Disable Code 39 Full ASCII Message Length Message length can be set to the maximum value, minimum value. The value is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail.
5.2.10 Coda bar Restore Factory Defaults Restore the Factory Defaults of Coda bar Enable/Disable Codabar *Enable Coda bar Disable Coda bar Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid.
Page 37
Transmit Start/Stop Character Transmit Start/Stop Character *Do not Transmit Start/Stop Character Coda bar Check Character No Check Char Validate and Transmit *Validate no Transmit...
5.2.11 Code 93 Restore Factory Defaults Restore the Factory Defaults of Code 93 Enable/Disable Code 93 *Enable Code 93 Disable Code 93 Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid.
5.2.12 GS1-128 Restore Factory Defaults Restore the Factory Defaults of GS1-128 Enable/Disable GS1-128 *Enable GS1-128 Disable GS1-128 Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming command.
5.2.13 MSI Restore Factory Defaults Restore the Factory Defaults of MSI Enable/Disable MSI Enable MSI *Disable MSI Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command.
5.3 2D Symbologies 5.3.1 PDF 417 Restore Factory Defaults Restore the Factory Defaults of PDF 417 Enable/Disable PDF 417 *Enable PDF 417 Disable PDF 417 Enable/Disable Micro PDF 417 *Enable Micro PDF 417 Disable Micro PDF 417 Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum.
5.3.2 QR Code Restore Factory Defaults Restore the Factory Defaults of QR Code Enable/Disable QR Code *Enable QR Code Disable QR Code Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum is valid.
5.3.3 Data Matrix Restore Factory Defaults Restore the Factory Defaults of Data Matrix Enable/Disable Data Matrix *Enable Data Matrix Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command.
5.3.4 Maxi code Restore Factory Defaults Restore the Factory Defaults of Maxi code Enable/Disable Maxi code Enable Maxi code *Disable Maxi code Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum.
5.3.5 Aztec Restore Factory Defaults Restore the Factory Defaults of Aztec Enable/Disable Aztec Enable Aztec *Disable Aztec Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command.
5.3.6 Hanxin Restore Factory Defaults Restore the Factory Defaults of Hanxin Enable/Disable Hanxin Enable Hanxin *Disable Hanxin Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command.
Postal Symbologies 5.4.1 China Postal Code Restore Factory Defaults Restore the Factory Defaults of China Postal Code Enable/Disable China Postal Code Enable China Postal Code *Disable China Postal Code...
Page 54
ASCII Special Table Char Char Char L-Ctrl L-Shift L-Alt L-GUI R-Ctrl R-Shift R-Alt R-GUI Caps Lock Print Screen Scroll Lock Pause Insert Delete Home Page Up Page Down Left Arrow Right Arrow Up Arrow Down Arrow Num Lock(keypad) 1(keypad) 2(keypad) 3(keypad) 4(keypad) 5(keypad)
Need help?
Do you have a question about the BD-6500BT and is the answer not in the manual?
Questions and answers