Hose/Tool Connections

Connecting Hoses
1. Pull up red bypass valve on reservoir.
2. Connect the return (tank) hose from the power unit
port to the tool return port (T).
Note: Return (tank) hose connection should always
be connected before pressure (supply) hose
connection to prevent pressure build-up inside
the tool.
3. Connect the pressure (supply) hose from the power
unit pressure port to the tool pressure port (P).
Note: A flow meter may be installed in the return line
to test the rate of flow in the system.
IMPORTANT
When new hoses are used, it is necessary to
prefill the hoses to keep the reservoir oil level
from dropping excessively. After connecting new
hoses to the unit, run the unit for a few minutes,
filling the hoses with oil. Stop the unit and check
the oil level of the reservoir. Refill as necessary.
Hydraulic oil should appear in the lower 1/4 of the
sight gauge.
Greenlee Textron / Subsidiary of Textron Inc.
HG3505A / 42303 Portable Power Unit
FLOW
METER
PRESSURE
RETURN
PORT (P)
PORT (T)
BYPASS
VALVE
RELIEF
VALVE
1400 PSI
PUMP
FILTER
ENGINE
Disconnecting Hoses
1. Stop the power unit.
2. Disconnect the pressure (supply) hose from the
power unit pressure port to the tool pressure
port (P).
Note: Pressure (supply) hose connection should
always be disconnected before return (tank)
hose connection to prevent pressure build-up
inside the tool.
3. Disconnect the return (tank) hose from the power
unit return port to the tool return port (T).
4. To prevent contamination, always install dust caps
over the hydraulic ports of the tool, hoses, and
power unit when disconnected.
PRESSURE
PORT (P)
TYPICAL
RETURN
TOOL
PORT (T)
POWER
UNIT
OIL
COOLER