1. SPECIFICATIONS Display: Liquid crystal display Power supply: Two lithium batteries (CR2032) Power consumption: 0.1 W When AC key is pressed; Max. 16.2 µA. Typ. 11.5 µA Current consumption: At DC6V Max. 13 µA While Power OFF; Max. 16,500 µA When backlighting;...
2. OPERATION CHECK Note: Performing this check, the data saved in the unit will be deleted. Therefore, save the data to another unit referring to “ 3. DATA TRANSFER” ( page 6 of this Service Manual) before performing this check. KEY OPERATION LCD DISPLAY NOTES...
Page 5
KEY OPERATION LCD DISPLAY NOTES Press SPAC No buzzer sound button after 1 ~ 2 seconds. Press ZAPISZ No buzzer sound button after 1 ~ 2 seconds. Press WL button after 1 ~ 2 No display No buzzer sound seconds. Unit’s power will be turned off.
3. DATA TRANSFER This unit can transfer the stored data to another unit. Note: Before connecting wires, be sure to reset the Back up unit. 1. Remove the BATT 2 battery cover. 2. Connect 4 terminals on the PCB with wires as shown in the figure below. User's unit Back up unit RESET...
Note: Perform the operation in numerical order. Back up unit User's unit Operation Display Operation Display 1 While pushing down RESET 2 While pushing down RESET button, press then re- (Unit emits a buzz.) button, press then re- (Unit emits a buzz.) lease RESET button.