Installing The Ocp 2.0 Mezzanine Card - Gigabyte R262-ZA0 User Manual

Amd epyc 7002 server system - 2u 42-bay
Hide thumbs Also See for R262-ZA0:
Table of Contents

Advertisement

3-7-2 Installing the OCP 2.0 Mezzanine Card

• Voltages can be present within the server whenever an AC power source is connected. This
voltage is present even when the main power switch is in the off position. Ensure that the system
is powered off and all power sources have been disconnected from the server prior to installing a
PCIe card.
• Failure to observe these warnings could result in personal injury or damage to equipment.
Follow these instructions to install an OCP 2.0 Mezzanine card:
1.
Remove the screw securing the OCP 2.0 card slot cover.
2.
Remove the slot cover from the system.
3.
Align the screw holes on the OCP 2.0 card with the heads of the stand-off screws ensuring that the
ports on the card are properly fitted into the rear panel of the system.
4.
Press down on the OCP 2.0 card so that the connector on the card is firmly connected to the
connector on the motherboard and then secure three screws on the card.
5.
Reverse steps 3-4 to replace the OCP 2.0 card.
System Hardware Installation
2
1
6
3
4
5
- 40 -

Advertisement

Table of Contents
loading

Table of Contents