LG LM-1460H2L Service Manual page 41

Multi type room air conditioner
Hide thumbs Also See for LM-1460H2L:
Table of Contents

Advertisement

9. Set the pipings and the connecting cable to
the back of the chassis with the tubing
holder.
• Hook the edge of tubing holder to tap on chas-
sis and push the bottom of tubing holder to be
engaged in the bottom of chassis.
10. Indoor unit installation.
• Hook the indoor unit onto the upper portion of
installation plate. (Engage the two hooks of the
rear top of the indoor unit with the upper edge
of the installation plate.)
Ensure the hooks are properly seated on the
installation plate by moving it in left and right.
All manuals and user guides at all-guides.com
- 41 -
Taping
Piping
Press the lower left and right side of the unit
against the Installation Plate until the hooks
engages with their slots (sound click).
Drain hose
Tubing holder
1
Hook
2
Push
Connecting
cable
Drain hose

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents