4-2 Connection Diagrams
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Field Reversing Shunt Motor
Shunt Field
F2
Interpole
Armature
F1
A1
+
Shunt Motor CCW Rotation
(Facing Commutator End)
High Voltage Field Connection
Field Reversing Shunt Motor
Shunt Field
F3
Interpole
Armature
F4
A1
+
Shunt Motor CW Rotation
(Facing Commutator End)
High Voltage Field Connection
DC Generator Connection Diagram
Compound Wound Short Shunt Connection
Shunt Field
F1
F2
F3
Comm. Field
A1
+
CCW Rotation
(Facing Commutator End)
For CW Rotation, Interchange Leads A1 and A2.
F3
A2
F4
−
F2
A2
F1
−
F4
Series Field
S2
A2
−
S1
MN605