CHANGE GAS SETTING (NATURAL GAS, PROPANE GAS)

10
Warning
After Natural Gas Setting, applying Propane Gas Orifice or wrong use of Natural Gas
!
Orifice will result in fire. Conversion must be made by a qualified technician.
Initially
STEP 1 : VALVE SETTING
Full open
"Change screw"
STEP 2 : ORIFICE CHANGE
Orifice
, Natural Gas mode is set. Propane Gas Orifice is on sale as a Service
Part to authorized servicers only.
28
Close
"Change screw"
Remove 2 screws.
Disassemble the pipe assembly.
Replace Natural Gas orifice with Propane Gas orifice.
Gas type
Orifice P/No
Natural Gas
4948EL4001B
Propane Gas
4948EL4002B
Kit contents : Orifice (Dia. = 1.613mm, for Propane Gas)
: Replace Label
: Instruction sheet
Shape
Marking
NCU
PCU