INF adjustment lens
To be used for adjustment of the camera system. For the
usage of the INF adjustment lens, refer to the Service Bulletin
No. YA-SB-10035.
INF adjustment lens holder
To be used together with the Camera stand for operating the
Videocamera in the stripped-down condition such as the sta-
tus without the exterior parts or for using commodities that are
not yet conformable to the interchangeable ring. For the usage
of the INF lens holder, refer to the Service Bulletin No. YA-SB-
10035.
Mini stand
To be used together with the INF adjustment lens holder. For
the usage of the Mini stand, refer to the Service Bulletin No.
YA-SB-10035.
Light box assembly
To be used for adjustment of the camera system. For the
usage of the Light box assembly, refer to the Service Bulletin
No. YA-SB-10035.
Gray scale chart
To be used for adjustment of the camera system. For the
usage of the INF adjustment lens, refer to the Service Bulletin
No. YA-SB-10035.
Color bar chart
To be used for adjustment of the camera system. For the
usage of the INF adjustment lens, refer to the Service Bulletin
No. YA-SB-10035.
PC cable
To be used to connect the Videocamera and a personal computer
with each other when a personal computer issued for adjustment.
Communication cable
Connect the Communication cable between the PC cable and
Jig connector cable when performing a PC adjustment.
Service support system
To be used for adjustment with a personal computer. Software
can be downloaded also from JS-net.
Jig connector cable
Connected to JIG CONNECTOR of the main board and used
for electrical adjustment, etc.
Conversion connector
Conversion connector is used to convert the connector part of
the JIG connector cable.
4.2
JIG CONNECTOR CABLE CONNECTION
Connection procedure
NOTE
Be sure to turn the power "OFF", when connecting the JIG
CONNECTOR CABLE.
If the JIG CONNECTOR CABLE is connected with the pow-
er "ON", communication error may occur.
1
CONVERSION
CONNECTOR
JIG
CONNECTOR
JIG CONNECTOR
CABLE
COMMUNICATION CABLE
JIG CONNECTOR
TO NU_RX
TO NU_TX
TO GND
Fig.4-2-1
CAUTION
The JIG CONNECTOR CABLE cannot be connected with
the COVER (JIG) removed because of its structure. It is nec-
essary to cut a part of the connector board as shown below.
Pay special attention during the procedure.
JIG CONNECTOR CABLE [YTU93106A]
3
2
COVER(JIG)
SERVICE
SUPPORT
SYSTEM
RS232C
MENU
COM PORT
PC CABLE
PERSONAL COMPUTER
FOR
COMMUNICATION CABLE
COMMUNICATION
CABLE
RED
WHITE
BLACK
: The part to be cut