American Standard S9X1 Installer's Manual page 105

Upflow/horizontal and dedicated downflow gas-fired, direct/non-direct vent, single stage / two stage condensing furnaces with high efficiency motor
Table of Contents

Advertisement

Run Test Mode:
To enter Run Test Mode, scroll to
mes, then begin the test.
To exit the test mode, momentarily push the Menu key, cycle power to the furnace, or make a valid thermostat
call for capacity or fan.
Sequence of Run Test Mode
-Turns the inducer on in 1
– Turns on the inducer on 2
– Turns the igniter on for 10 seconds
– Turns the circula ng blower on 1 stage compressor speed for 10 seconds
– Turns the circula ng blower on 2 stage compressor speed for 10 seconds (N/A for S9B1)
– Turns the circula ng blower on 1
– Turns on the circula ng blower on 2
The above sequence will repeat two more mes unless the Run Test Mode is exited, see above
Important: The Run Test Mode does not test fire the furnace or bring the outdoor unit on. It is designed to allow
the technician to observe each mode to ensure the IFC, inducer, and circula ng blower are performing as
intended.
Example
IdL
Tap #2
Ht1
TP2
Ht2
Tp4
CL1
TP3
CL2
TP7
HP1
TP3
HP2
Tp7
COF
Tp1
DFT
TP3
18-CE12D1-1D-EN
S9X1 – S9X2 – S9B1
Run Test Mode
using the Menu key, then push the op on key. The LED will flash
st
stage for 30 seconds
nd
stage for 30 seconds (N/A for S9B1/S9X1)
st
nd
st
stage gas heat speed for 10 seconds
nd
stage gas heat speed for 10 seconds (N/A for S9B1, S9X1)
S9X1 – S9X2 – S9B1
System Status Menu
Example
1st Stage Pressure
Switch Error
e3.1
IDL = Idle, no demand for cooling, heating, or fan
HT1 = Demand for 1
HT2 = Demand for 2
CL1 = Demand for 1
CL2 = Demand for 2
HP1 = Demand for 1
HP2 = Demand for 2
COF = Demand for continuous fan
DFT = Demand for outdoor unit defrost, furnace running in gas heat mode
TP1-9 = Tap selected for airflow
NOTE:
(1) The menu status displayed is solely dependent on the input of 24VAC that is
applied to the low voltage terminal strip.
(2) The status will alternate between the system mode and the airflow request every 2
seconds.
(3) If an error occurs, an E*.* will alternately flash with the system mode and airflow
request. See first example
I I n n t t e e g g r r a a t t e e d d F F u u r r n n a a c c e e C C o o n n t t r r o o l l M M e e n n u u
st
stage gas heat ( Ht = S9X1 & S9B1)
nd
gas heat
st
stage cooling ( CP1 = S9X1 & S9B1)
nd
stage cooling ( CP2 = S9X1)
st
stage heat pump (CP1 = S9X1 & S9B1)
nd
stage heat pump (CP2 = S9X1)
three
105