State of abnormality
The wireless activation lamp does
not light/blink.
Cannot finish tool registration / can-
celling tool registration successfully.
Probable cause (malfunction)
The wireless unit is not installed into
the tool.
The wireless unit is improperly installed
into the tool.
The terminal of the wireless unit and/or
the slot is dirty.
The wireless activation button on the
tool has not been pushed.
The stand-by switch on the cleaner is
not set to "AUTO".
No power supply
The wireless unit is not installed into
the tool.
The wireless unit is improperly installed
into the tool.
The terminal of the wireless unit and/or
the slot is dirty.
The stand-by switch on the cleaner is
not set to "AUTO".
No power supply
Incorrect operation
The tool and cleaner is away from each
other (out of the transmission range).
Before finishing the tool registration/
cancellation;
- the switch trigger on the tool is pulled
or;
- the power button on the cleaner is
turned on.
The tool registration procedures for the
tool or the cleaner has not finished.
Radio disturbance by other appliances
which generate high-intensity radio
waves.
14 ENGLISH
Remedy
Install the wireless unit correctly in the tool.
Gently wipe off dust and dirt on the terminal of the
wireless unit and clean the slot of the tool.
Push the wireless activation button on the tool
briefly.
Set the stand-by switch on the cleaner to "AUTO".
Supply the power to the tool and the cleaner.
Install the wireless unit correctly in the tool.
Gently wipe off dust and dirt on the terminal of the
wireless unit and clean the slot of the tool.
Set the stand-by switch on the cleaner to "AUTO".
Supply the power to the tool and the cleaner.
Push the wireless activation button briefly and
perform the tool registration/cancellation procedures
again.
Get the tool and the cleaner closer to each other.
The maximum transmission distance is approxi-
mately 10 m however it may vary according to the
circumstances.
Push the wireless activation button briefly and
perform the tool registration/cancellation procedures
again.
Perform the tool registration procedures for the tool
and the cleaner at the same timing.
Keep the tool and the cleaner away from the appli-
ances such as Wi-Fi devices and microwave ovens.