Crown GCX-2-6 Installation & Operation Manual page 14

Gas cabinet base convection steamer with direct steam kettle(s)
Table of Contents

Advertisement

INSTALLATION AND OPERATION MANUAL, GAS FIRED PRESSURELESS COOKER WITH
DIRECT STEAM KETTLES, MODELS GCX-2-6, GCX-2-10, GCX-2-6-6 AND GCX-2-6-10
BOILER CONTROLS (Inside Cabinet) - Continued
Water Level Sight Glass
Water Level Control
Safety Valve
WARNING: In the event you smell gas, shut down equipment at the
main shut off valve and contact the local gas company or gas
supplier for service.
1. START UP - BOILER OPERATION WITH STANDING PILOT IGNITION
Open manual gas shut off supply valve and if the appliance has a manual blowdown valve,
close it. Open cabinet door and turn ON power switch located on left side. Green pilot light will
come on, water will begin to enter boiler and required water level will be reached in about three
minutes. Observe water gauge glass to verify.
The dial on the combination gas control valve has three positions (ON-PILOT-OFF) for manual
gas control of main burners and pilot. Turn DIAL to PILOT. Depress dial and light pilot burner
located on centre main burner of boiler. Maintain dial in depressed position for about 30
seconds and release. Observe that the pilot burner flame stays on. If at any time the flame
should become extinguished, a 5 minute period of complete shut off of gas supply is required
before relighting.
Turn dial to ON and burners should ignite. Steam generation will now commence and be
completed in approximately 15 minutes. Steam generation should reach approximately 11 psi
as indicated on the pressure gauge on the boiler.
PART NUMBER 10122R1
-
Observe level of water in the boiler and water quality.
Murkiness in the water indicates inadequate water quality; the
owner must supply proper water to the boiler. See page 4
Water Quality Statement.
-
While ON, briefly open the water level control daily to remove
any sediment that might accumulate.
-
This valve will release (pop off) if the boiler has too much
pressure. Once a week, this valve should be tripped during
operation to make sure it functions properly.
14
2003-10-09

Advertisement

Table of Contents
loading

Table of Contents