PROBlEM
i cannot select a 6V or
12V setting.
the yellow/orange
LED is flashing.
the red
LED is
flashing.
17. SPECIFICATIONS
input .................................................................................................. 230V Ac~50Hz, 0.5A
output ................................................................................................. 6V
Dimensions – H x W x D ...........................................................193 mm x 84 mm x 78 mm
Weight ..................................................................................................................... 0.65 kg
output protection .......................................................................................................... Yes
reverse polarity protection, spark/arc-proof ................................................................. Yes
ingress Protection rating ..............................................................................................iP54
POSSIBlE CAUSE
the charger is equipped with
Auto Voltage Detection, which
automatically detects the voltage
and charges the battery.
the battery is sulfated.
the battery is too large for the
charger.
the clamps are not making a
good connection.
the fuse is bad.
Sole uK Distributor,
Sealey Group.
Kempson Way,
Suffolk Business Park,
Bury St. Edmunds, Suffolk.
iP32 7Ar
no problem; this is normal.
Reset the charger by briefly
unplugging it.
You need a charger with a higher
amp rate.
check for poor connection at
battery and frame.
replace the in-line fuse for the
ring connector.
10
REASON/SOlUTION
2A, 12V
www.sealey.co.uk
Web
sales@sealey.co.uk
01284 757500
01284 703534
2A