ZXT-510
AC MASTER
Lite
INSTALLATION GUIDE

Advertisement

Table of Contents
loading

Summary of Contents for Z-Wave AC MASTER LITE

  • Page 1 ZXT-510 AC MASTER Lite INSTALLATION GUIDE...
  • Page 3: Table Of Contents

    Z-Wave Glossary ............... 4 Get Started ............. 6 Step 1 Apply Power to ZXT-510 ........6 Step 2 Include ZXT-510 to a Z-Wave Gateway ....6 Step 3 Setup Automatic Status Report Association to Gateway ................... 7 Step 4 Setup Air Conditioner IR code ....... 7 Other Setup Options through Configuration .....
  • Page 4 Caution ..............23...
  • Page 5: Introduction

    Enabled Z-Wave Plus Controller must be used in order to fully utilize the product. ZXT-510 is a Z-Wave slave device, it depends on gateway to setup particular AC brand with correct IR code. Different gateway has dif- ferent user interface for setup.
  • Page 6: Product Overview

    Product Overview...
  • Page 7: Features

    • Support firmware upgrades via Over-the-air (need Gateways support) Z-Wave Glossary Device or Node Devices and nodes are all terms to describe an indi- vidual Z-Wave device. These are all interchangeable when setting up your Z-Wave network. Inclusion Add a Z-Wave device to the network.
  • Page 8 Z-Wave Network A collection of Z-Wave devices is controlled by prima- ry and secondary controllers operating on the same system. A Z-Wave network has its own unique ID code so that controllers not in the network cannot control the system.
  • Page 9: Get Started

    • 1 x CR123A battery or micro USB • ZXT-510 will detect the first applied power source to decide what Z-Wave device role it will be in after included into the Z-Wave gateway: battery= sleeping device (FLiRS mode). USB power = always awake device (Always Listening mode), refer to Z-Wave Glossary for more information.
  • Page 10: Step 3 Setup Automatic Status Report Association To Gateway

    UI for the IR code setup please refer to the gateway UI and ignore the below steps. • If your gateway does not have dedicated UI for ZXT-510 IR code setup, but support Z-Wave thermostat Command Class...
  • Page 11 and Con- figuration Command Class. You may refer to below steps to setup the IR code using the configuration options in your gateway...
  • Page 12 Step Procedure / Description Status Indicator Refer to your primary controller user manual, enter to the browser page that can input the Configuration parameter. Input parameter number “27” and Green Indicator will parameter value (refer to brand and turn on. If fail, Red code list in hardcopy or download Indi- cator will flash softcopy from our website).
  • Page 13 IR Code Learning Step Procedure / Description Status Indicator Refer to your primary controller user manual, enter to the browser page that can input the Configuration parameter Look up Below mapping table for learn- ing, and decide the IR setting you intend to learn next.
  • Page 14 Tips • Make sure your Original Remote is in Power OFF Status. • Make sure your Original Remote set FAN Speed to AUTO and FAN SWING to AUTO/ON • Press and Hold the Power Key on Original Remote UNTIL AC Mas- ter indicate Successful or Not. •...
  • Page 15 IR Learning Mapping Table (Parameter Number 25) Thermostat Command & IR Setting Parameter Value (Storage Storage in Celsius Storage in Fahrenheit Unit Location) Unit ON (RESUME) ON (RESUME) 17°C COOL 63°F COOL 18°C COOL 64°F COOL 19°C COOL 66°F or 67°F COOL 20°C COOL 68°F or 69°F COOL 21°C COOL...
  • Page 16 23°C HEAT 74°F or 75°F HEAT 24°C HEAT 76°F HEAT 25°C HEAT 77°F or 78°F HEAT 26°C HEAT 79°F or 80°F HEAT 27°C HEAT 81°F or 82°F HEAT 28°C HEAT 83°F or 84°F HEAT 29°C HEAT 85°F HEAT 30°C HEAT 86°F HEAT DRY MODE DRY MODE...
  • Page 17 Important Information After all learning completed, User can go back to the ZXT- 510 control page on the gateway for normal operation. • On the Gateway UI, User can only use the Temperature range from the mapping table, OFF, ON(RESUME), COOL, HEAT, DRY MODE, AUTO MODE and FAN MODE.
  • Page 18: Other Setup Options Through Configuration

    Other Setup Options through Configuration Paramete Size Functions Parameter Value ( bytes) Number Default: 0x0000 range: (0x0000 to 0x20) Learn IR code 25 (0x19) refer to learning mapping table Default: 0x00 range: 0 to 4 (0x00 to 0x04) 0(0x00) : Idle - IR Channel is idle 1(0x01) : OK - the last learning opera- tion was completed...
  • Page 19 Set Built- in IR Emitter Control ( If there are two or more Air Condition- ers with the Default: same code 0xFF 0 or set that are 255 (0x00 or 32 (0x20) used in the 0xFF) same room, 0(0x00): Disable user can 255(0xFF): Enable (Default) disable the...
  • Page 20 Temperature offset value. 0(0x00) = 0°C (Default) 1(0x01) = 1°C 2(0x02) = 2°C 3(0x03) = 3°C Calibrate 4(0x04) = 4°C temperature 37 (0x25) 5(0x05) = 5°C reading 255(0xFF) = -1°C 254(0xFE) = -2°C 253(0xFD) = -3°C 252(0xFC) = -4°C 251(0xFB) = -5°C 0(0x00) = Disable AUTO report func- tion (Default) (for saving battery life)
  • Page 21 Note: All the above Parameter Number and Value is in Hexadecimal Numbering Format, if the Gateway only support decimal numbering format, please change it to deci- mal value accordingly. Mapping Information • BASIC Set Value 0x00 will map to Thermostat mode OFF 0x00 •...
  • Page 22: Reset To Factory Default

    Reset to Factory Default Press and Hold “PROG” button for 3 seconds on AC Master, the Green Indicator will light up. DO NOT Release the “PROG” Button until Green Indicator flashes TWICE. Important : ZXT-510 will not implement the reset to factory default when the battery level equal or below 50% Remark : All the setting and data will be permanently deleted.
  • Page 23: Mounting Location Tips

    Mounting Location Tips The ZXT-510 should be mounted on an inner wall about 5ft (1.5m) above the floor where it is readily affected by changes of the general room temperature with freely circulating air. Before mounting, check the material and structure of the mounting location.
  • Page 24: Technical Specifications

    Technical Specifications Model no. BW8290US (ZXT- 510US) BW8290EU (ZXT-510EU) BW8290AU (ZXT- 510AU) BW8290JP (ZXT-510JP) BW8290KR (ZXT- 510KR) BW8290IN RF Frequency 908.4MHz (ZXT-510US) (ZXT-510IN) 868.4MHz (ZXT-510EU) BW8290CN (ZXT- 921.4MHz (ZXT-510AU) 510CN) 922.5MHz (ZXT-510JP) 920.9MHz (ZXT-510KR) 865.2MHz (ZXT-510IN) 868.4MHz (ZXT-510CN) Up to 132ft outdoor line of sight, in Operating Distance unobstructed environment Temperature...
  • Page 25: Warranty

    WARRANTY ONE-YEAR LIMITED WARRANTY: Remotec warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the original date of purchase from the distributors or dealer. REMOTEC shall not be liable for: •...
  • Page 26: Regulatory Information

    Regulatory information FCC ID : M7N-BW8290 FCC Compliance Statement This device complies with Part 15 of the FCC rules. Operation is sub- ject to the following two conditions: • This device may not cause harmful interference, and • This device must accept any interference received, including inter- ference that may cause undesired operation.
  • Page 27: Ic Notice

    IC Notice This device complies with Industry Canada licence-exempt RSS stan- dard(s). Operation is subject to the following two conditions: • This device may not cause interference, and • This device must accept any interference, including interference that may cause undesired operation of the device.