Download Print this page

Kenwood TS-B2000 Service Manual Supplement page 54

All mode multi-band transceiver
Hide thumbs Also See for TS-B2000:

Advertisement

TS-2000/X,TS-B2000
Item
Condition
Band
MAIN
MAIN
MAIN
MAIN
MAIN
MAIN
SUB
SUB
MAIN
MAIN
MAIN
SUB
SUB
SUB
21. SSB
1) Menu No. : 23
S-meter
(Frequency : 14.2MHz)
S1 (HF)
AGC : ON
PRE-AMP : ON
SQL : Counterclockwise max. DM. SP
(Level min.)
RF GAIN : Clockwise max.
SSG f. : 14.201MHz
SSG output : –107dBm/1µV
S9
2) Menu No. : 24
SSG output : –81dBm/19.9µV
Full scale
3) Menu No. : 25
(Lights up all)
SSG output : –21dBm/19900µV
22. FM
1) Menu No. : 26
S-meter
(Frequency : 29.2MHz)
S1 (HF)
SSG f. : 29.200MHz
SSG output : –117dBm/0.316µV
MOD : 1kHz
DEV : 3kHz
Full scale
2) Menu No. : 27
(Lights up all)
SSG output : –95dBm/3.98µV
23. 50MHz
1) Menu No. : 29
SSB S-meter
(Frequency : 50.2MHz)
S1
SSG f. : 50.201MHz
SSG output : –111dBm/0.63µV
S9
2) Menu No. : 30
SSG output : –85dBm/12.6µV
Full scale
3) Menu No. : 31
(Lights up all)
SSG output : –25dBm/12600µV
54
ADJUSTMENT
Measurement
Test-
Unit
equipment
Frequency (K) Frequency (E) Mode SSG RF level (dBm) SSG MOD
550kHz
550KHz
14.200MHz
14.200MHz
18.200MHz
18.200MHz
52.200MHz
52.200MHz
146.200MHz
145.200MHz
146.200MHz
145.200MHz
118.200MHz
146.200MHz
145.200MHz
440.200MHz
435.200MHz
430.200MHz
430.200MHz
449.200MHz
439.200MHz
444.200MHz
430.200MHz
438.200MHz
435.200MHz
449.200MHz
439.200MHz
SSG
Rear
panel
AF V.M
Oscilloscope
Adjustment
Terminal
Unit
Parts
AM
–85
1kHz
USB
–119→OFF
OFF
USB
–119→OFF
OFF
FM
–118
1kHz
AM
–106
1kHz
FM
–121
1kHz
AM
–85
1kHz
FM
–117
1kHz
FM
–122
1kHz
FM
–121
1kHz
FM
–121
1kHz
FM
–117
1kHz
FM
–117
1kHz
FM
–117
1kHz
ANT1
Front
[+] key 1 push
panel
or
EXT. SP
[–] key
Specifications/Remarks
Method
DEV
Measurement
Spec.
60%→OFF
S/N
>10dB
OFF
S/N
>10dB
OFF
S/N
>10dB
3kHz
SINAD
>12dB
60%→OFF
S/N
>10dB
3kHz
SINAD
>12dB
60%→OFF
S/N
>10dB
3kHz
SINAD
>12dB
3kHz
SINAD
>12dB
3kHz
SINAD
>12dB
3kHz
SINAD
>12dB
3kHz
SINAD
>12dB
3kHz
SINAD
>12dB
3kHz
SINAD
>12dB
S-meter lights up to S1 level.
S-meter lights up to S9 level.
S-meter lights up all.
S-meter lights up to S1 level.
S-meter lights up all.
S-meter lights up to S1 level.
S-meter lights up to S9 level.
S-meter lights up all.

Advertisement

loading

This manual is also suitable for:

Ts-2000xTs-2000Ts-2000le