Grounding Method - LG T7567NEDL Series Owner's Manual

Table of Contents

Advertisement

G
rounding Method
Earth wire should be connected.
If the earth wire is not connected, there is possible a danger of electric shock caused
by the current leakage .
Grounding Method with Ground insert space Terminal
If the AC current outlet has a ground terminal, then
separate grounding is not required.
lko/kkuh
CAUTION /
Concerning the Power Cord
Most appliances recommend they be placed upon a dedicated circuit; that is, a single outlet circuit which powers only that
appliance and has no additional outlets or branch circuits. Check the specification page of this owner's manual to be certain.
Do not overload wall outlets. Overloaded wall outlets, loose or damaged wall outlets, extension cords, frayed power cords,
or damaged or cracked wire insulation are dangerous. Any of these conditions could result in electric shock or fire.
Periodically examine the cord of your appliance, and if its appearance indicates damage or deterioration, unplug it,
discontinue use of the appliance, and have the cord replaced with an exact replacement part by an authorized servicer. Protect
the power cord from physical or mechanical abuse, such as being twisted, kinked, pinched, closed in a door, or walked upon.
Pay particular attention to plugs, wall outlets, and the point where the cord exits the appliance
ikoj dkW M Z ds fo"k; es a
vf/kdrj midj.kks a dks ,d lefiZ r lfdZ V ij j[kus dks flQkfj'k dh tkrh gS ] ftlls ,d ls vf/kd midj.k u tq M + s gks a A
lEiw . k tkudkjh ds fy, bl vkW u lZ iq f Lrdk ds funs Z ' kks a dks tk¡ p ys a A fLopcks M Z ij vf/kd Hkkj u Mkys a A nhokj okyk eYVh
Iyx] <hyk] Vw V k] {kfrxz L r o my>h gq b Z ] dVh QVh rkj [krjukd gks ldrh gS a A ,lh fdlh Hkh fLFkfr es a vkx yxus ;k
>Vdk yxus dh la H kkouk gS A vius mRikn dh ikW o j dkW M Z dks le;&le; ij tk¡ p rs jgs a vkS j {kfrxz L r fn[kkbZ ns u s ij
midj.k dk Iyx ckgj fudky ns a vkS j midj.k dk bLrs e ky cUn dj ns a vkS j ikW o j dkW M Z dks vf/kd` r Mhyj ls gh
cnyok;s a A ikW o j dkW M Z dks okg; midj.kks a ls gks u s okyh gkfu ls cpk;s a A tS l s & eq M + u k] dq p yuk ;k njokts es a vkukA fLop
cks M Z ] Iyx o og txg tgk¡ ls ikW o j dkW M Z ckgj fudyrh gS ij fo'ks " k :i ls /;ku ns a A
Other Grounding Method
Burying Copper Plate
Connect the Ground Wire to a Ground Copper
Plate and bury it more than 75cm in the ground.
Using Ground Wire
Connect the ground Wire to the socket provided
exclusively for Grounding.
Using a Short Circuit Breaker
If grounding methods described above are not possible,
a separate circuit breaker should be employed and
installed by a qualified electrician.
Ground Copper Plate
32
Ground terminal
Grounding is
not needed
Ground Wire
75cm
Ground
Wire
Short-circuit
breaker