Daewoo KOG-8A275S Service Manual page 14

Table of Contents

Advertisement

6. To remove high voltage capacitor.
1) Remove the screw which secure the grounding ring
terminal of the H.V. diode and the capacitor holder.
2) Remove the H.V. diode from the capacitor holder.
3) Reverse the above steps for reassembly.
High voltage circuit wiring
7. To remove magnetron.
1) Remove the screw which secure the magnetron.
2) Remove the magnetron.
3) Reverse the above steps for reassembly.
NOTE : Never install the magnetron without the metallic gasket plate which is packed with each magnetron to
prevent microwave leakage. Whenever repair work is carried out on magnetron, check the microwave leakage. It
shall not exceed 4mW/cm
Metallic
gasket
plate
Cooling fin
<MAGNETRON>
2
for a fully assembled oven with door normally closed.
Magnetron
antenna
Filament
terminal
Wave guide Magnetron antenna
Metallic gasket plate
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kog-8a275s39Kog-8a275s40

Table of Contents