Be sure to read this manual carefully before using this product. Especially Legal Disclaimer, Statement of Conditions and Safty Warnings. VC-410 & VC-410 & VC410POE is a Long Reach Ethernet Extender with PoE equipped with two 10/100Mbps Ethernet ports with power injector. It delivers data and electrical power to access points using standard Category 5 Ethernet cable that provide an economical solution for commercial-grade applications.
VC-410 & VC410POE Ethernet Extender Manual Safety Warnings For your safety, be sure to read and follow all warning notices and instructions before using the device. DO NOT open the device or unit. Opening or removing covers can expose you to dangerous high voltage points or other risks.
2. Use ONLY the dedicated power supply for your device. Do not use sub-standard power supply. Before connecting the power supply to the device, be sure to check compliance with specifications. The VC-410 & VC410POE support DC48V /1.875A power input. 3. Power supply included in package is commercial-grade. Do not use in industrial-grade applications.
VC-410 & VC410POE Ethernet Extender Manual Chapter 2. Installing the Bridge 2.1 Hardware Installation This chapter describes how to install the bridge and establishes network connections and may install the bridge on any level surface (e.g. a table or shelf or rail). However, please take note of the following minimum site requirements before one begin.
The devices attached to these ports must support auto-negotiation or 10Base-T or 100Base-TX unless they will always operate at half duplex. VC-410 & VC410POE fast Ethernet port is used to connect to external power splitter(PoE) or build in power splitter of networking devices such as IP CAM, VOIP, wireless AP, sensor scanner or other power splitter(PD side) more than 30W.
VC-410 & VC410POE Ethernet Extender Manual 2.5 Connecting the RJ-11 / RJ-45 Ports The line port has 2 connectors: RJ-45 and terminal block. It is used to connect from VC-410 & VC410POE(CO) using single pair phone cable to VC-410 & VC410POE(CPE) side (point to point solution).
VC-410 & VC410POE Ethernet Extender Manual 2.6 VDSL2 bridge Application 1. User can use VC-410 & VC410POE bridge (CO mode) to connect VC-410 & VC410POE bridge (CPE mode), or use VC-410 & VC410POE bridge (CO mode) to connect VC-410 &...
Page 12
2. If user need use over 1.5 km cable length and also need bigger bandwidth application, such as connect to ip camera. User can use VC-410 & VC410POE (CO mode) and VC-410 & VC410POE (CPE mode) to achieve the ip surveillance for long distance application. (Figure 2.7)
VC-410 & VC410POE Ethernet Extender Manual Chapter 3. Hardware Description The following section describes the important parts of the VDSL2 bridge with PoE. It features the front panel and rear panel. VC-410 & VC410POE Outwards...
VC-410 & VC410POE Ethernet Extender Manual 3.1 Front Panel The figure shows the front panel. (Figure 3.1) Figure 3.1 Front Panel And the table shows the description. (Table 3-1) Table 3-1 Description of the bridge front connectors...
Page 15
VC-410 & VC410POE Ethernet Extender Manual Note: Two Bridges connection may take within 3 minutes is normal, due to VC-410 & VC410POE to establish a link mechanism is auto-negotiation, with detects and calculate CO and CPE both PBO and PSD level as well as noise level ..and other argument etc. for getting a better...
VC-410 & VC410POE Ethernet Extender Manual 3.3 Rear Panel The following figure shows the rear panel. (Figure 3.2) Figure 3.2 Rare Panel And the table shows the description. (Table 3-3) Table 3-3 Description of the bridge front connectors The following figure shows the DIP switch connection. By switching the transmission modes, you can obtain a best transmission mode to suit with phone line quality or distance or connectivity.
Page 17
VC-410 & VC410POE Ethernet Extender Manual Figure 3.3 DIP switch setting Table 3-4 DIP Switch Configuration Note: 1. The DIP switch default value are OFF. 2. Please power off VC-410 & VC410POE, before making any transmission mode configuration.
Page 18
Tip: When the VC-410 & VC410POE operates at CPE mode, the DIP switch 2, 3, 4 has no function. PIN2: ON: High Band mode(500KHz to 30MHz), and enable VDSL2 spectrum is 500kHz to 30MHz. It can pass through ISDN spectrum(0 ~ 499KHz are empty).
Page 19
VC-410 & VC410POE Ethernet Extender Manual TIP(Reference Only): Interleave delay function is used in digital data transmission technology to protect the transmission against noise issue and data error. If during transit more than a certain amount of data has been lost then the data cannot be correctly decoded.
Page 20
2. Please note that the user can use 48VDC power input. Do not exceed DC 48V. 3. Be sure to disconnect the power before installing and/or wiring your VC-410 & VC410POE bridge. 4. Please calculate the maximum possible current in each power wire and common wire.
Page 21
VC410POE come with for grounding the switches. For optimal EMS performance, connection of the left side of the VC-410 & VC410POE rear panel ground lug to the grounding point. Before user installed power and device, please read and follow these essentials: Use separate paths to route wiring for power and devices.
VC-410 & VC410POE Ethernet Extender Manual Appendix A: Cable Requirements Ethernet Cable A CAT 3~7 UTP (unshielded twisted pair) cable is typically used to connect the Ethernet device to the bridge. A 10Base-T cable often consists of four pairs of wires, two of which are used for transmission.
Page 23
VC-410 & VC410POE Ethernet Extender Manual Figure A-2 Pin Assignments and Wiring for an RJ-45 Straight-Through Cable Figure A-3 Pin Assignments and Wiring for an RJ-45 Crossover Cable...
Page 24
VC-410 & VC410POE Ethernet Extender Manual Appendix B: Product Specification Key Features & Benefits Provides 2 x 10/100 Mbps RJ-45 Ethernet ports with power injector Supports RJ-11/Terminal Block combo for Line port. Supports high bandwidth up to 100Mbps symmetric over Line ports...
VC-410 & VC410POE Ethernet Extender Manual Appendix C: Troubleshooting Diagnosing the Bridge’s Indicators The bridge can be easily monitored through its comprehensive panel indicators. These indicators assist the network manager in identifying problems the hub may encounter. This section common problems you may encounter and possible solutions.
Page 27
VC-410 & VC410POE Ethernet Extender Manual The protocol was standardized in the International Telecommunication Union telecommunications sector (ITU-T) as Recommendation G.993.2. It was announced as finalized on 27 May 2005,[1] and first published on 17 February 2006. Several corrections and amendments were published in 2007 through 2011.
Page 28
VC-410 & VC410POE Ethernet Extender Manual System Diagnostics Power and Cooling Problems If the POWER indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or internal power supply as explained in the previous section.
VC-410 & VC410POE Ethernet Extender Manual Appendix D: Compliance Information FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a computing device, pursuant to Part 15 of FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Page 30
VC-410 & VC410POE Ethernet Extender Manual This equipment may not be used on coin service provided by the telephone company. Connection to party lines is subject to state tariffs. FCC Warning This equipment has been tested to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
VC-410 & VC410POE Ethernet Extender Manual WEEE Warning To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment, end users of electrical and electronic equipment should understand the meaning of the crossed-out wheeled bin symbol.