Fault
The temperature in
the freezer compartment is
too warm.
Freezer compartment door
was open for a long time;
temperature is no longer
reached.
Possible cause
Appliance opened
frequently.
The ventilation openings
have been covered.
Large quantities of fresh
food are being frozen.
The evaporator (refrigeration
generator) in the NoFrost
system is covered in thick ice
and can no
longer be defrosted fully
automatically.
Remedial action
Do not open the appliance unnecessarily.
Remove obstacles.
Do not exceed max. freezing capacity.
To defrost the evaporator, remove the frozen
food with the compartments, insulate well
and store in a cool location.
Switch off the appliance and move it away
from the wall. Leave the appliance door open.
After approx. 20 min. the condensation begins
to run into the evaporation pan,
at the rear of the appliance. Fig. .
To prevent the evaporation pan
from overflowing in this case,
mop up the condensation with a sponge.
The evaporator is defrosted when the water
stops running into the evaporation pan. Clean
the interior. Switch the appliance
back on again.