Troubleshooting

The majority of faults which could occur in
daily operation can be rectified by the
user. This ensures that the appliance is
quickly available for use again. The
following overview will help you locating
the causes and gives helpful advise to
eliminate them.
Note
If the appliance stops during dishwashing
for no obvious reason, first run the Abort
programme function (Reset).
(See chapter entitled "Basic functions")
ã=
Warning
Don't forget: Repairs may be carried out
by technicians only. If a component has to
be replaced, ensure that only original
spare parts are used. Improper repairs or
use of non-original spare parts may cause
considerable damage and put the user at
considerable risk.

Waste water pump

Large food remnants in the rinsing water
not retained by the filters may block
the waste water pump. The rinsing water
is then not pumped out and covers
the filter.
In this case:
– First disconnect the appliance from
the power supply.
– Remove the bottom basket.
– Remove the filters 1b.
(See chapter entitled Maintenance
and care)
– Scoop out water, use a sponge if
required.
– Using a spoon, prise off pump cover
(as illustrated) until it clicks, then grip
the cover by the lug and pull it out
forwards.

– Check inner compartment and remove
any foreign objects.
– Place cover in the original position,
press down and engage.
FOLFN

– Install filters.
Note
If the cover is not engaged properly, this
may cause a programme interruption and
the "Tap 6" display H is indicated.