Mitsubishi Electric MFZ-KJ25VE-E2 Service Manual page 17

Split-type air conditioners
Table of Contents

Advertisement

9-10. EMERGENCY/TEST OPERATION
In the case of test run operation or emergency operation, use
EMERGENCY OPERATION switch on the right side of the indoor unit.
Emergency operation is available when the remote controller is miss-
ing or has failed, or when the batteries in the remote controller are
running down. The unit will start and OPERATION INDICATOR lamp
will light up.
The first 30 minutes of operation is the test run operation. This opera-
tion is for servicing. The indoor fan runs at High speed and the tem-
perature control does not work. In COOL MODE, the air outlet selec-
tion is set to 2 FLOW during the test run operation.
After 30 minutes of test run operation, the system shifts to
EMERGENCY COOL/HEAT MODE with a set temperature of 24°C.
The fan speed shifts to Medium.
The coil frost prevention works even in the test run or the emergency
operation.
In the test run or emergency operation, the horizontal vane operates
in VANE AUTO ( ) mode.
Emergency operation continues until EMERGENCY OPERATION
switch is pressed once or twice or the unit receives any signal from
the remote controller. In the latter case, normal operation will start.
NOTE: Do not press EMERGENCY OPERATION switch during nor-
mal operation.
9-11. 3-MINUTE TIME DELAY OPERATION
When the system turns OFF, compressor will not restart for 3 minutes as 3-minute time delay function operates to protect
compressor from overload.
OBH666B
Operation mode
Set temperature
Fan speed
Horizontal vane
Air outlet
The operation mode is indicated by the Operation
Indicator lamp as following
Operation Indicator lamp
EMERGENCY COOL
EMERGENCY HEAT
STOP
Emergency
operation switch
(E.O. SW)
17
COOL/HEAT
24°C
Medium
Auto
2 FLOW
Lighted
Not lighted

Advertisement

Table of Contents
loading

Table of Contents