9-6. AUTO VANE OPERATION
1. Horizontal vane (Horizontal vane/Multi-flow vane)
(1) Vane motor drive
These models are equipped with a stepping motors for the horizontal vanes. The rotating direction, speed, and angle
of the motor are controlled by pulse signals (approximately 12 V) transmitted from indoor microprocessor.
(2) The horizontal vane angle and mode change as follows by pressing VANE CONTROL (
(3) Positioning
The vane presses the vane stopper once to confirm the standard position and then moves to the set angle.
Confirming of standard position is performed in case of follows.
(a) The power supply turns on.
(b) The operation starts or finishes (including timer operation).
(c) The test run starts.
(d) The multi-standby starts or finishes.
(e) Every time the vane has swung more than the specified numbers of times.
( f) The horizontal vane automatically moves in certain intervals to determine its position, and then it returns to
set position.
(g) The vane operates for the dew prevention.
(4) Air outlet selection
The air outlet(s) can be selected by pressing to VANE CONTROL (
When 2 FLOW is selected, air blows from the top and the front of the unit. When 1 FLOW is selected, air blows only
from the top of the unit.
The multi-flow vane is automatically set to the appropriate position.
In HEAT, the multi-flow vane automatically changes its position according to the indoor fan speed.
Even if 2 FLOW is selected, air will blow only from the top of the unit in the following conditions:
• During COOL/DRY: The room temperature is close to set temperature.
The air conditioner has operated for 0.5 to 1 hour.
• During HEAT: The air flow temperature is low. (During defrosting operation, start of operation, etc.)
NOTE:
Movement at the start of the 2 FLOW operation
• COOL/DRY, HEAT: It takes 0.5 to 1 minute to start the 2 FLOW operation.
• HEAT: When cold air blows out from the air outlet, the multi-flow vane may stop moving for up to 10 minutes to
make and blow out warm air.
(5) VANE AUTO ( ) mode
In VANE AUTO mode, the microprocessor automatically determines the vane angle to make the optimum room tem-
perature distribution.
In COOL, DRY and FAN operation
2 FLOW: Vane angle is fixed to position 2.
1 FLOW: Vane angle is fixed to position 1.
OBH666B
(AUTO)
(1)
(2)
(2 FLOW)
(3)
(4)
) button.
(1 FLOW)
In HEAT operation
2 FLOW: Vane angle is fixed to position 2.
1 FLOW: Vane angle is fixed to position 3.
13
) button.
(SWING)