Test & connection
17. Test & connection
L
110 - 240VAC
N
M
M

Connect the load to the screw connector marked by "LOAD" see fig. 1. Consider the max. load (5,5A)

Connect the mains voltage on the screw connector "MAINS".

See whether you have mounted the right jumper (J1 or J2).

The power voltage for the load is put on the connector. "VAC" (24 ... 240VAC).

See that this voltage and the "MAINS" voltage have the same frequency and that they are either in phase
or in the opposite phase. Owing to the fact that the supply voltages of the load and the control circuit are
completely separated, one can also connect low voltage loads. This makes this circuits fits for regulations
8

ATTENTION:
L
A PART OF THE CIRCUIT IS ALWAYS UNDER MAIN
N
VOLTAGE. TAKE ALL POSSIBLE PRECAUTIONS, SO
N
L
THAT
L
NO-ONE CAN TOUCH ANY PART. FOR YOUR OWN
SECURITY AS FOR THE USERS' SECURITY. MOUNT
N
THIS KIT PREFERABLY IN AN ISOLATING HOUSING.
N
THE FUSE WILL MELT IN CASE OF AN OVERLOAD, RE-
PLACE IT BY EXACTLY THE SAME TYPE.
L
Fig 1.0