9. TROUBLESHOOTING

ERROR CODE
e001
e002
e003
e004
e005
e006
e007
e008
e009
e010
e011
e012
e013
e014
e015
e016
e017
e018
e019
e020
e021
e022
e023
14
CAUSE
all battery over-voltage protection.
all battery low-voltage protection.
all battery failure.
all battery discharge
over-temperature protection.
all battery discharge
low-temperature protection.
all battery charge
over-temperature protection.
all battery charge
low-temperature protection.
1st group battery
low-voltage protection.
2nd group battery
low-voltage protection.
3rd group battery
low-voltage protection.
4th group battery
low-voltage protection.
inverter bus cable voltage failure.
inverter over-load protection.
inverter short-circuit.
inverter cooling fan discharge
over-temperature protection.
inverter cooling fan temperature
detector is not working.
pV input over-voltage protection.
internal over-temperature protection. check if the working temperature is too high.
pV cooling fan over-temperature
protection.
pV cooling fan temperature
detector is not working.
battery protection board charge
protection.
battery false protection.
Generator over-load (ac&dc)
protection.
SOLUTION
no charge, only discharge.
fully charged and restart.
restart kodak ppS1800 and charge it.
temperature is too high.
restart when cooler.
ambient environment temperature is too low.
restart when environment temperature is higher.
the temperature of the battery pack is too high.
charge when the temperature is lower.
the temperature of the battery pack is too low.
charge when the temperature is higher.
charge and restart.
charge and restart.
charge and restart.
charge and restart.
turn off and restart.
reduce the load. restart ac.
correct the short-circuit output. restart ac.
restart when the cooling fan temperature is
lower.
connect ntc and restart.
check to ensure you have correctly configured
the solar panel array to provide the correct
input voltage.
if yes: disconnect pV and turn back on and
connect pV
if the temperature is within the operating
range, disconnect the pV, switch off the device
and then reconnect the pV.
recharge after the cooling fan temperature is
lower.
restart kodak ppS1800.
recharge after the protection board tempera-
ture is back to normal
disconnect pV. restart.
reduce the total load and restart.