Summary of Contents for Avlite AV-OL-60

  • Page 1 AV-OL-60 Solar Obstruction Light Installation & Service Manual Version 1.2...
  • Page 3: Table Of Contents

    Maintenance and Servicing ..............Page 14 Troubleshooting ................Page 15 Avlite Light Warranty .................Page 18 Version No. Description Date Approved Manual Launch November 2015 T. Stewart Update: Selecting an intensity December 2015 W.Evans Contact details June 2016 J. Dore Latest products and information available at www.avlite.com...
  • Page 4: Introduction

    Precision Construction Commitment to investing in the design and construction of injection-moulded parts including optic lenses, light bases and a range of other components ensures that all Avlite products are of a consistent and superior quality. Optical Performance Avlite manufactures a range of aviation LED lenses moulded from multi-cavity dies.
  • Page 5: Av-Ol-60 Model

    AV-OL-60 Solar Obstruction Light AV-OL-60 Model The AV-OL-60 is a field proven, low maintenance, self-contained solar LED light that is suitable for a variety of applications including general hazard, caution, barricade and low-intensity obstruction lighting. Latest products and information available at www.avlite.com...
  • Page 6 Waterproof IP68 Intellectual Property Patents US Pat. No. 6,667,582. AU Pat. No. 778,918 Trademarks AVLITE® is a registered trademark of Avlite Systems Warranty * 3 year warranty Options Available • IR LEDs • External ON/OFF Switch • External Battery Charging Port •...
  • Page 7: Installation

    6. To test place dark cover (towel or jacket) on top of light to activate sensor, light will come on within one minute. 7. Ensure that the unit is bolted to an even, flat surface. Light Base Rotary Switch B User Replaceable Battery Rotary Switch A ON / OFF Switch Intensity Setting Latest products and information available at www.avlite.com...
  • Page 8: Selecting An Intensity/Power Setting

    Solar Obstruction Light Selecting an Intensity/Power Setting Intensity/power settings on Avlite lanterns operate via DIP switches, located near the rotary switches on the flasher unit. The intensity/power settings may be used to reduce the power consumption and intensity of the lantern. Setting the lantern to 25% intensity will reduce the power consumption to 25% of the normal 100% setting and the range by 25%.
  • Page 9: Flash Codes

    It is best to operate at the lowest duty cycle appropriate to the actual needs of the application. Please note, Avlite models will retain full autonomy in normal operating conditions with duty-cycles up to approximately 30%. In applications whereby duty cycles exceed this limit, a reduction in light intensity is recommended.
  • Page 10 FL 5 S FL 15 S 14.0 FL 5 S LFL 15 S 11.0 FL 5 S OC 15 S FL 5 S LFL 20 S 18.0 FL 5 S FL 26 S 25.0 Latest products and information available at www.avlite.com...
  • Page 11 15.0 FL (2) 25 S 22.0 SWITCH FLASH CODE Q (3) 5 S VQ (3) 5 S VQ (3) 5 S VQ (3) 5 S FL (3) 6 S FL (2+1) 6 S Latest products and information available at www.avlite.com...
  • Page 12 FL (4) 20 S FL (4) 20 S 13.5 FL (4) 20 S 10.5 FL (4) 20 S Q (4) 20 S 16.5 Q (4) 28 S 24.5 FL (4) 30 S 26.5 Latest products and information available at www.avlite.com...
  • Page 13 MO (A) 10 S MO (D) 10 S MO (A) 15 S 11.0 MO (U) 15 S 11.8 MO (U) 15 S 10.7 MO (U) 15 S 10.1 MO (B) 15 S 10.5 Latest products and information available at www.avlite.com...
  • Page 14: Maintenance And Servicing

    Always discard old batteries in a safe manner. Long Term Storage Instructions If the AV-OL-60 is to be placed in storage for an extended period, being more than 5 months, please follow the below steps.
  • Page 15: Troubleshooting

    • Expose light to direct sunlight and monitor operation for several days. entire night. Avlite products typically require 1.5 hours of direct sunlight per day to retain full autonomy. From a discharged state, the light may require several days of operational conditions to ‘cycle’ up to full autonomy.
  • Page 16 AV-OL-60 Solar Obstruction Light Notes Latest products and information available at www.avlite.com...
  • Page 17 AV-OL-60 Solar Obstruction Light Notes Latest products and information available at www.avlite.com...
  • Page 18: Avlite Light Warranty

    Avlite or authorised Avlite repair personnel.
  • Page 19 5. No modifications to the original specifications determined by Avlite shall be made without written approval of Avlite Systems. 6. Avlite lights can be fitted with 3rd party power supplies and accessories but are covered by the 3rd party warranty terms and conditions.
  • Page 20 • Helipad lighting • Obstruction lighting Portable Airfi eld Lighting For a complete list of product compliances System including ICAO & FAA, please contact Avlite today AUSTRALIA t: +61 (0)3 5977 6128 t: +1 (603) 737 1310 UNITED KINGDOM t: +44 (0) 1502 588026 A subsidiary of Sealite Pty Ltd www.sealite.com...

Table of Contents