Installer Reference Guide
PR115B-PR116B

Connection Diagram

The optional CM444B relay module provides
an easy way to interface the readers lock
Because of its small physical size
(12.5 x 46 x 12mm) it can be easily located
in the wall cavity if required.
CM720 or CM723
Power Supply
(Battery backed up)
DOOR
LOCK
+
PROTECTION
DIODE
Wiring Legend
RED
= LAN +
BLACK
= LAN -
WHITE
= LAN A
BLUE
= LAN B
YELLOW
= LOCK
GREEN
= EGRESS
You must power cycle the panel or perform
i
a LAN scan after connecting the PR115B or
Note
PR116B for the system to initialise the reader.
6
output to the door lock.
CM444 RELAY CARD
CM444 Relay Card
N/O
COM
DF70
N/C
TO
DOOR
LOCK
EGRESS
INPUT
Figure 4: Connection Diagram
Address Select Switch. Keypads and LAN
Readers must be set to a unique address as
per "Table 2: Address Table" on page 2
All LAN Readers are supplied from
the factory set to Address 1.
+12V
YL
Lock
BL
Output
WH
BK
RD
GN
Egress
Input
The egress input
is low (0V) to trigger.
Disable via panel
programming if not
being used.
Bosch Security Systems 10/13 PR115B-PR116BIRG FTR1.0
Make sure that the
keypad buzzer opening
is not blocked
during installation
or the volume will be
greatly reduced.