MANUALE DI MONTAGGIO ED USO
ASSEMBLY INSTRUCTIONS AND USER
ICON TAPS 2/3 TASTI
ICON COLUMN 2/3 TASTI
ICON TAPS 3 TASTI - ICON TAPS 3 BUTTONS
ICON TAPS 2 TASTI - ICON TAPS 2 BUTTONS
ICON COLUMN 2 TASTI - ICON COLUMN 2 BUTTONS
ICON COLUMN 3 TASTI - ICON COLUMN 3 BUTTONS
Edizione / Edition: 05/02/2021

Advertisement

loading
Need help?

Need help?

Do you have a question about the ICON TAPS 2 TASTI and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HAFRO ICON TAPS 2 TASTI

  • Page 1 ICON COLUMN 2/3 TASTI ICON TAPS 3 TASTI - ICON TAPS 3 BUTTONS ICON TAPS 2 TASTI - ICON TAPS 2 BUTTONS ICON COLUMN 2 TASTI - ICON COLUMN 2 BUTTONS ICON COLUMN 3 TASTI - ICON COLUMN 3 BUTTONS...
  • Page 2 PREDISPOSIZIONI ICON TAPS 2 TASTI PREDISPOSIZIONI ICON TAPS 3 TASTI PREPARATIONS ICON TAPS 2 BUTTONS PREPARATIONS ICON TAPS 3 BUTTONS LEGENDA / LEGEND: LEGENDA / LEGEND: A - Attacco a muro acqua calda da 1/2” F A - Attacco a muro acqua calda da 1/2” F Hot water wall connection 1/2 ”F...
  • Page 3 NUOVA INSTALLAZIONE / NEW INSTALLATION PARTE INCASSO BUILT-IN SECTION IMMAGINE A SCOPO INDICATIVO (VEDI PAGINE SEGUENTI PER L’INSTALLAZIONE) IMAGE FOR INDICATIVE PURPOSE (SEE FOLLOWING PAGES FOR INSTALLATION) DATI SPEDIZIONE / SHIPPING DATA: INGOMBRI IMBALLO / PACKING DIMENSIONS PESO / WEIGHT PARTE INCASSO ICON ALTEZZA / HEIGHT NETTO / NET...
  • Page 4 PREDISPOSIZIONI COLONNA 2 TASTI PREDISPOSIZIONI COLONNA 3 TASTI 2 BUTTON COLUMN ARRANGEMENTS 3 BUTTON COLUMN ARRANGEMENTS 11.7 10.5 16.5 LEGENDA / LEGEND: A - Attacco a muro acqua calda da 1/2” F R - Zona per fissaggio rubinetteria T - Fori per fissaggio colonna doccia Hot water wall connection 1/2 ”F Area for fixing taps Holes for fixing shower column...
  • Page 5 NUOVA INSTALLAZIONE / NEW INSTALLATION PARTE INCASSO BUILT-IN SECTION IMMAGINE A SCOPO INDICATIVO (VEDI PAGINE SEGUENTI PER L’INSTALLAZIONE) IMAGE FOR INDICATIVE PURPOSE (SEE FOLLOWING PAGES FOR INSTALLATION) ATTACCHI GIA’ ESISTENTI / ATTACKS ALREADY EXISTING PARTE INCASSO ICON BUILT-IN SECTION 1 5 c m DATI SPEDIZIONE / SHIPPING DATA: INGOMBRI IMBALLO / PACKING DIMENSIONS PESO / WEIGHT...
  • Page 6: Dati Tecnici / Technical Data

    DATI TECNICI / TECHNICAL DATA ICON TAPS 2 TASTI ICON TAPS 2 BUTTONS ICON TAPS 3 TASTI ICON TAPS 3 BUTTONS PRESSIONE DINAMICA / DYNAMIC PRESSURE (BAR) DOCCETTA / SHOWER HAND l/min l/min 10.8 12.2 13.4 14.6 15.7 16.7 17.6 2/3°...
  • Page 7 BEFORE PERFORMING CONNECTION OF THE APPLIANCE THE INSTALLER MUST REQUEST THE DECLARATION OF CONFORMITY OF THE PLUMBING AND ELECTRICAL SYSTEMS AS SET FORTH BY ITALIAN LAW NR.46 DEL 05/03/90. IN THE ABSENCE OF THIS DOCUMENTATION HAFRO S.R.L. DECLINES ANY RESPONSIBILITY FOR PREMISES AND SYSTEMS WHERE THEIR APPLIANCE IS INSTALLED.
  • Page 8 FERRAMENTA / HARDWARE PARTE INCASSO / BUILT-IN SECTION POS. FIGURA Q.TA’ POS. FIGURA Q.TA’ DESCRIZIONE DESCRIZIONE TASSELLO FISCHER RACCORDO FISCHER DOWELA FITTING Ø6 VITE STAFFA FISSAGGIO SCREW FIXING BRACKET 3.9x32 FERRAMENTA / HARDWARE ICON TAPS 2/3 TASTI - ICON TAPS 2/3 BUTTONS FIGURA FIGURA POS.
  • Page 9 SAME FOR ALL THE PRODUCTS LISTED BELOW. ICON TAPS 3 TASTI - ICON TAPS 3 BUTTONS ICON TAPS 2 TASTI - ICON TAPS 2 BUTTONS ICON COLUMN 2 TASTI - ICON COLUMN 2 BUTTONS ICON COLUMN 3 TASTI - ICON COLUMN 3 BUTTONS...
  • Page 10: Installazione / Installation

    INSTALLAZIONE / INSTALLATION ● RUBINETTERIA 2/3 TASTI / 2/3 BUTTON TAPS ● COLONNA 2/3 TASTI / COLUMN 2/3 BUTTON X 1 pz X 2/3/4 pz TEFLON SOLO SE PREVISTO ONLY IF PROVIDED X 4 pz X 4 pz...
  • Page 11 M A X 3 0 m - 0 mm - 0 mm - 0 mm +5 mm +5 mm +5 mm...
  • Page 12 = (75 mm) = (75 mm) Ø 6 mm L X 1 pz X 1 pz X 1 pz P X 1 pz TEFLON 150 mm...
  • Page 13 VALVOLE DI NON RITORNO NON-RETURN VALVES K X 1 pz 0 (zero) 0 (zero)
  • Page 14 ● ICON TAPS 2/3 TASTI - ICON TAPS 2/3 BUTTONS ICON TAPS 2 TASTI ICON TAPS 2 BUTTONS ICON TAPS 3 TASTI ICON TAPS 3 BUTTONS TEFLON ● ICON COLUMN 3 TASTI - ICON COLUMN 3 BUTTONS N X 2 pz...
  • Page 15 T X 1 pz ● ICON TAPS 2/3 TASTI - ICON TAPS 2/3 BUTTONS ● ICON COLUMN 3 TASTI - ICON COLUMN 3 BUTTONS...
  • Page 16 ● ICON COLUMN 3 TASTI - ICON COLUMN 3 BUTTONS X 2 pz X 2 pz 1 0 5 m X 1 pz X 2 pz Ø 8 mm 8 4 m m...
  • Page 17 C X 1 pz O X 2 pz Ø 8 mm...
  • Page 18 X 1+1 pz X 2 pz J X 2 pz U X 2 pz...
  • Page 19 X 2 pz X 4 pz...
  • Page 20 M X 2 pz...
  • Page 21 V X 4 pz...
  • Page 22 T X 1 pz ● ICON COLUMN 2 TASTI - ICON COLUMN 2 BUTTONS & X 1 pz & Z X 1 pz X X 1 pz Y X 1 pz Ø 8 mm 1 0 1 m...
  • Page 24 ● ICON TAPS 2/3 TASTI - ICON TAPS 2/3 BUTTONS ● ICON COLUMN 3 TASTI - ICON COLUMN 3 BUTTONS X 1 pz X 1 pz W X 1 pz ● ICON COLUMN 2 TASTI - ICON COLUMN 2 BUTTONS X 1 pz X 1 pz W X 1 pz...
  • Page 25 ISTRUZIONI D’USO / USE MANUAL Ci complimentiamo con voi per aver scelto un prodotto progettato e realizzato per rispondere nel migliore dei modi alle vostre esigenze di benessere. COMANDI IDRAULICI Icon Taps/Column è fornita con rubinetto termostatico. La manopola termostatica imposta e stabilizza la temperatura dell’acqua.
  • Page 26 PULIZIA / CLEANING IMPORTANTE: RICORDIAMO CHE LA GARANZIA NON COPRE I DANNI CAUSATI DAL DEPOSITO DI CALCARE O IMPURITA’ O SE L’APPARECCHIO RISULTERA’ AVER SUBITO TRATTAMENTI DIVERSI DA QUELLI DA NOI QUI SUGGERITI. Per evitare danni al vostro bagno o all’apparecchiatura vi invitiamo ad osservare la seguente raccomandazione di utilizzo: 1.
  • Page 27: Manutenzione / Maintenance

    MANUTENZIONE / MAINTENANCE Nel caso sia necessario sostituire uno o più componenti, contattare un nostro centro assistenza autorizzato. Vedi documento allegato “CENTRI ASSISTENZA TECNICA E RICAMBISTICA” oppure visita il nostro sito WWW.GRUPPOGEROMIN.COM Prima di effettuare qualsiasi intervento alla rubinetteria chiudere i rubinetti dell’acqua posti fuori dall’ingombro del prodotto. If it is necessary to replace one or more components, contact our authorized service center.
  • Page 28: Warnings For Use

    Avvertenze per l’installazione L’azienda declina ogni responsabilità qualora: 1) Il prodotto non sia installato da personale qualificato o abilitato. 2) Non siano rispettate le disposizioni d’installazione e manutenzione riportati sui manuali. 3) Non siano rispettate le normative e disposizioni di legge relativi agli impianti elettrici ed idraulici (ultime edizioni). 4) Non siano rispettate le norme citate nel presente manuale.