  • Page 1 AUTO PUMP HEATER <TEMP SET> HOLD BUTTON TO ADJUST PRESS BOTH TO READ ACTUAL User’s Guide User’s Guide Models Covered ByThis User’s Guide : SP601-15 SP601-20 SP601-30 SP400P SP601-15T SP601-20T SP601-30T SP400PAU-10 SP601AU-15 SP601AU-20 SP601AU-30 SP400PAU-15 SP601AU-15T SP601AU-20T SP601AU-30T...
  • Page 2: Table Of Contents

    Contents Section Touch Pads............................Pg 1 Temperature Control..........................Pg 2 - Adjusting Set Temperature....................Pg 2 - Non Default Display Value....................Pg 2 - Heating Mode Selection(24hr circulation pump not fitted)..........Pg 2 Pump Operation..........................Pg 3 - Pump 1 (Single speed pump, no 24hr circulation pump fitted)........Pg 3 - Pump 1 (Single speed pump, 24hr circulation pump fitted)..........
  • Page 3: Touch Pads

    Congratulations on choosing the latest Spa Power control system. This controller makes use of the latest technology, including innovative optical and digital sensor designs. The greater variety of optional accessories, user- friendly touchpad and reliable components provide you with the most sophisticated controller in its class.
  • Page 4: Temperature Control

    2 Temperature Control The Spa Power controller automatically controls the pump and heater to filter the water and maintain it at the desired temperature set by the user (see below).The user can leave the system to look after the spa and know it will be at the correct temperature whenever he or she wants to use it.
  • Page 5: Pump Operation

    3 Pump Operation There are four possible variations of pump 1 that may have been fitted to your spa, this user guide covers all variations of pump 1 that could have been fitted. Please read sections 3.1 through to 3.4 then follow the section which matches your spa operation.
  • Page 6: Pump 1 (Two Speed Pump,No 24Hr Circulation Pump Fitted)

    3.3 Pump 1 (Two speed, no 24HR circulation pump fitted) Pump 1 is controlled by just one touch pad button pushing the pump button 4 times cycles its operation through 4 modes Automatic, Manual Low Speed, Manual High Speed and Standby. When the spa is running in automatic mode, pressing the pump 1 button will deactivate auto mode and set the pump running in Manual low speed.
  • Page 7: Auxiliary/Air Button

    4 Auxiliary Air Button The Air Button controls an auxiliary air blower. It is used to turn the blower on and off, and select different operating modes if a Spa Power Variable-Speed Blower (SPVSB) has been fitted. 2 pushes (STD) or 4 pushes (SPVSB) of the air button cycles the blower as follows: Note: In some spas an additional jet pump or pool light etc may be fitted instead of a standard air blower.
  • Page 8: Light Operation

    5 Light Operation Your spa may have been fitted with either of two different LED lights; a Spa Power Coloured Light (SPCL) or a Spa power Variable Coloured Light (SPVCL). The Spa Power Coloured Light is a single coloured light that is either on or off. The Spa Power Variable Coloured light is a light that has the ability to change between 12 different colours and white (see below for user instructions).
  • Page 9: Auto Sanitisation

    6 Auto Sanitising (Filtration) 6.1 No 24hr Circulation Pump Fitted The Spa Power controller automatically maintains the filtration/sanitising of the spa pool water. The minimum amount of filtration time is programmable by the user and can be adjusted between 0 and 15 minutes per hour (0 to 6 hours per day).
  • Page 10: Sleep Timer

    7 Sleep Timer (Optional Timeclock) If the optional time clock has been fitted, sleep mode is used to disable automatic temperature maintenance and filtration in order to silence the spa 9 : 31 pool during your hours of sleep. The sleep time setting is done using the digital time clock on the front of the control box (See below for setting instructions).
  • Page 11: Self Diagnostic Error Codes

    8 Self-Diagnostic Error Codes The Spa Power controller has extensive self diagnostic capabilities. In the event of a problem it will indicate an error number according to the nature of the problem. The error numbers and their meanings are listed below. Note: When in an error state the alarm can be muted by pushing theAIR/AUX button.
  • Page 12 Spa-Quip Ltd Spa-Quip Ltd Spa-Power Equipment Spa-Power Equipment www.spa-quip.com.au www.spa-quip.co.nz service@spa-quip.com.au service@spa-quip.co.nz Ph: 1300 797 828 Ph: 64 9 415 8622 Fax: 61 3 9730 9367 Fax: 64 2 415 8621 6 Lakeview Drive 2 Rothwell Ave Scoresby, VIC 3179 Australia...

Table of Contents