NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices to
available water lines. This can, however, cause electrical feedback in the plumbing circuit, which results in
an "electrolysis" effect occurring in the fountain. This may result in water which has a metallic taste to it or
has a noticeable increase in the metallic content of the water.
When inspecting plumbing circuit, remember the line may be grounded some distance from the
installation, and may occur outside the building or area in which the unit is being installed.
This condition can be avoided (in most cases) by using recommended materials during installation.
Any drain fittings provided by the installer should be made of plastic which will electronically isolate the
fountain from the remainder of the building's plumbing circuits.
ENOB2-8C, ENOB2-8RAC
INSTALLATION & USE MANUAL
Refrigerated fountains with FLEXI-GUARD
ENOB2-8C
Review these instructions before beginning installation. Be sure that installation
conforms to all plumbing, electrical and other applicable codes.
When installation is complete, ensure these instructions are left with building owner
for future reference.
Service to be performed by authorized service personnel only.